Libuse Trnkova

Prof. Libuse Trnkova

Laboratories of Biophysical Chemistry and Electrochemistry (LABIFEL), Department of Chemistry (A12/229), Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2000 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
LTLibuse Trnkova
Libuse Trnkova
Rene KizekRene Kizek
Rene Kizek
ODOldřich Dračka
Oldřich Dračka

27 May 2010 in Sensors
Verified
Journal Article
Open access
PDF file
OKOlga Krystofova
Olga Krystofova
LTLibuse Trnkova
Libuse Trnkova
Vojtech AdamVojtech Adam
Vojtech Adam
JZJosef Zehnalek
Josef Zehnalek
Jaromir HubalekJaromir Hubalek
Jaromir Hubalek
Rene KizekRene Kizek
Rene Kizek
Routine determination of trace metals in complex media is still a difficult task for many analytical instruments. The aim of this work was to compare three electro-chemical instruments [a standard potentiostat (Autolab), a commercially available miniaturized potentiostat (PalmSens) and a homemade micropotentiostat] for easy-to-use and sensitive determination of cadmium(II) and lead(II) ions. The lowest detection limits (hundreds of pM) for both metals was achieved by using of the standard potentiostat, followed by the miniaturized potentiostat (tens of nM) and the homemade instrument (hundreds of nM). Nevertheless, all potentiostats were sensitive enough to evaluate contamination of the environment, because the environmental limits for both metals are higher than detection limits of the instruments. Further, we tested all used potentiostats and working electrodes on analysis of environmental samples (rainwater, flour and plant extract) with artificially added cadmium(II) and lead(II). Based on the similar results obtained for all potentiostats we choose a homemade instrument with a carbon tip working electrode for our subsequent environmental experiments, in which we analyzed maize and sunflower seedlings and rainwater obtained from various sites in the Czech Republic.


8 November 2011 in Sensors
Verified
Journal Article
Open access
PDF file
JSJiri Sochor
Jiri Sochor
Ondrej ZitkaOndrej Zitka
Ondrej Zitka
DHDavid Hynek
David Hynek
EJEva Jilkova
Eva Jilkova
LKLudmila Krejcova
Ludmila Krejcova
Rene KizekRene Kizek
Rene Kizek
Cadmium, as a hazardous pollutant commonly present in the living environment, represents an important risk to human health due to its undesirable effects (oxidative stress, changes in activities of many enzymes, interactions with biomolecules including DNA and RNA) and consequent potential risk, making its detection very important. New and unique technological and biotechnological approaches for solving this problems are intensely sought. In this study, we used the commonly occurring potential pathogenic microorganism Staphylococcus aureus for the determination of markers which could be used for sensing of cadmium(II) ions. We were focused on monitoring the effects of different cadmium(II) ion concentrations (0, 1.25, 2.5, 5, 10, 15, 25 and 50 µg mL−1) on the growth and energetic metabolism of Staphylococcus aureus. Highly significant changes have been detected in the metabolism of thiol compounds—specifically the protein metallothionein (0.79–26.82 mmol/mg of protein), the enzyme glutathione S-transferase (190–5,827 µmol/min/mg of protein), and sulfhydryl groups (9.6–274.3 µmol cysteine/mg of protein). The ratio of reduced and oxidized glutathione indicated marked oxidative stress. In addition, dramatic changes in urease activity, which is connected with resistance of bacteria, were determined. Further, the effects of cadmium(II) ions on the metabolic pathways of arginine, β-glucosidase, phosphatase, N-acetyl β-D-glucosamine, sucrose, trehalose, mannitol, maltose, lactose, fructose and total proteins were demonstrated. A metabolomic profile of Staphylococcus aureus under cadmium(II) ion treatment conditions was completed seeking data about the possibility of cadmium(II) ion accumulation in cells. The results demonstrate potential in the application of microorganisms as modern biosensor systems based on biological components.

14 January 2015 in Sensors
Verified
Journal Article
Open access
PDF file
VSVimal Sharma
Vimal Sharma
FJFrantisek Jelen
Frantisek Jelen
LTLibuse Trnkova
Libuse Trnkova
Interest in electrochemical analysis of purine nucleobases and few other important purine derivatives has been growing rapidly. Over the period of the past decade, the design of electrochemical biosensors has been focused on achieving high sensitivity and efficiency. The range of existing electrochemical methods with carbon electrode displays the highest rate in the development of biosensors. Moreover, modification of electrode surfaces based on nanomaterials is frequently used due to their extraordinary conductivity and surface to volume ratio. Different strategies for modifying electrode surfaces facilitate electron transport between the electrode surface and biomolecules, including DNA, oligonucleotides and their components. This review aims to summarize recent developments in the electrochemical analysis of purine derivatives, as well as discuss different applications.

31 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
JHJan Hrbac
Jan Hrbac
VHVladimir Halouzka
Vladimir Halouzka
LTLibuse Trnkova
Libuse Trnkova
JVJan Vacek
Jan Vacek
In electrochemical sensing, a number of voltammetric or amperometric curves are obtained which are subsequently processed, typically by evaluating peak currents and peak potentials or wave heights and half-wave potentials, frequently after background correction. Transformations of voltammetric data can help to extract specific information, e.g., the number of transferred electrons, and can reveal aspects of the studied electrochemical system, e.g., the contribution of adsorption phenomena. In this communication, we introduce a LabView-based software package, ‘eL-Chem Viewer’, which is for the analysis of voltammetric and amperometric data, and enables their post-acquisition processing using semiderivative, semiintegral, derivative, integral and elimination procedures. The software supports the single-click transfer of peak/wave current and potential data to spreadsheet software, a feature that greatly improves productivity when constructing calibration curves, trumpet plots and performing similar tasks. eL-Chem Viewer is freeware and can be downloaded from www.lchem.cz/elchemviewer.htm.