Iris de Krom

Dr. Iris de Krom


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
IKIris de Krom
Iris de Krom
WBWijnand Bavius
Wijnand Bavius
RZRuben Ziel
Ruben Ziel
EMElizabeth A. McGhee
Elizabeth A. McGhee
Richard J C BrownRichard J C Brown
Richard J C Brown
HEHugo Ent
Hugo Ent
A primary mercury gas standard was developed at Van Swinden Laboratory (VSL) to establish an International System of Units (SI)-traceable reference point for mercury concentrations at emission and background levels in the atmosphere. The majority of mercury concentration measurements are currently made traceable to the empirically determined vapour pressure of mercury. The primary mercury gas standard can be used for the accurate and precise calibration of analytical systems used for measuring mercury concentrations in air. It has been especially developed to support measurements related to ambient air monitoring (1–2 ng m−3), indoor and workplace-related mercury concentration levels according to health standards (from 50 ng m−3 upwards) as well as stationary source emissions (from 1 µg m−3 upwards). The primary mercury gas standard is based on diffusion according to ISO 6154-8. Calibration gas mixtures are obtained by combining calibrated mass flows of nitrogen and air through a generator holding diffusion cells containing elemental mercury. In this paper, we present the results of comparisons between the primary gas standard and mercury calibration methods maintained by NPL (National Physical Laboratory in the United Kingdom), a National Metrology Institute (NMI), and the Jozef Stefan Institute (JSI), a Designated Institute (DI). The calibration methods currently used at NPL and JSI are based on the bell-jar calibration apparatus in combination with the Dumarey equation or a NIST (National Institute of Standards and Technology in the United States) reference material. For the comparisons, mercury was sampled on sorbent traps to obtain transfer standards with levels between 2 and 1000 ng with an expanded uncertainty not exceeding 3 % (k=2). The comparisons performed show that the results for the primary gas standard and the NIST reference material are comparable, whereas a difference of −8 % exists between results traceable to the primary gas standard and the Dumarey equation.

23 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KAkarine arrhenius
karine arrhenius
HBHaleh Bohlen
Haleh Bohlen
OBOliver Büker
Oliver Büker
IKIris de Krom
Iris de Krom
DHDita Heikens
Dita Heikens
JWJanneke van Wijk
Janneke van Wijk
The ISO 14687-2 standard sets requirements for the purity of the hydrogen that is delivered at refuelling stations. These specifications cover a wide range of impurities and include challenging measurements, mainly due to the very low levels of the required detection limits and the need for “total” measurements (total hydrocarbons, total sulphur compounds, halogenated compounds). Most of the compounds belonging to the species are organic. Thermal desorption often coupled with gas chromatography is a common speciation method used to determine the content of organic impurities. However, no existing sorbent tubes are sufficiently universal to trap all possible impurities; depending on the sorbents and the sampling volume, some compounds may irreversibly adsorb or may break through. It is therefore necessary to evaluate sorbents for the compounds targeted at the level required. In this study, the suitability of sorbent tubes for trapping organic impurities in hydrogen was investigated. Suitable sorbents were selected based on a literature review of suitable sorbent materials. Short-term stability studies for compounds among hydrocarbons, halogenated compounds and sulphur compounds on the selected sorbents have then been performed for storage periods of two weeks since this is the period typically required to complete the collection, transport and analysis of hydrogen samples. The study clearly shows that the method is promising for total species, even through the results show that not all of the compounds belonging to the three total species to be analysed when performing hydrogen purity analysis can be quantified on one unique sorbent. A multibed sorbent consisting of Tenax TA (weak), Carboxen 1003 (medium), Carbograph 1 (strong) is shown to be a versatile sorbent suitable for the three “total species”; only a few compounds from each family would need to be analysed using other analytical methods. This method proposed here for total species will not only provide a sum of concentrations, but also an identification of which compound(s) is/are actually present in the hydrogen.

17 February 2023 in Research Square
Verified
Preprint
Open access
PDF file
AVAdriaan M.H. van der Veen
Adriaan M.H. van der Veen
IKIris de Krom
Iris de Krom
RZRuben Ziel
Ruben Ziel
GNGerard Nieuwenkamp
Gerard Nieuwenkamp
LCLucy Pandora Culleton
Lucy Pandora Culleton
JAJohn Allden
John Allden
Siloxanes are silicon-containing volatile organic compounds that occur in air, biogas and biomethane. Their presence in biogas and biomethane may give rise to silica deposits in gas transmission and distribution infrastructure, as well as in end-user appliances. The silicon concentration in biomethane is therefore regulated, and implementing these regulations requires reliable measurement methods and appropriate certified reference materials (CRMs) to calibrate analytical instruments. In this work, the primary measurement standards of two national metrology institutes are compared to assess their equivalence by means of gas chromatography analysis. The comparison addressed hexamethyldisiloxane (L2), octamethyltrisiloxane (L3), hexamethylcyclotrisiloxane (D3), octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) in methane gas mixtures. Two mixtures were exchanged, one with siloxane amount fractions at the ppb-level as specified in the European specification EN 16723, and a second on ppm-level. The latter CRMs can be dynamically diluted or directly used to process concentrated biomethane samples. The results at both levels demonstrate equivalence in the preparation and analysis of the addressed siloxanes in methane.