Chunyu Qiao

Dr. Chunyu Qiao

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Cement and Concrete Composites
Verified
Journal Article
Closed access
CQChunyu Qiao
Chunyu Qiao
PSPrannoy Suraneni
Prannoy Suraneni
TYThen Nathalene Wei Ying
Then Nathalene Wei Ying
ACAntara Choudhary
Antara Choudhary
JWJason Weiss
Jason Weiss

1 May 2018 in Construction and Building Materials
Verified
Journal Article
Closed access
CQChunyu Qiao
Chunyu Qiao
PSPrannoy Suraneni
Prannoy Suraneni
JWJason Weiss
Jason Weiss

1 August 2019 in Cement and Concrete Research
Verified
Journal Article
Closed access
SSScott H. Smith
Scott H. Smith
CQChunyu Qiao
Chunyu Qiao
PSPrannoy Suraneni
Prannoy Suraneni
KKKimberly E. Kurtis
Kimberly E. Kurtis
WWWilliam J. Weiss
William J. Weiss

1 February 2018 in Cement and Concrete Composites
Verified
Journal Article
Closed access
CQChunyu Qiao
Chunyu Qiao
PSPrannoy Suraneni
Prannoy Suraneni
JWJason Weiss
Jason Weiss

29 July 2016 in Advances in Civil Engineering Materials
Verified
Journal Article
Closed access
WWW. J. Weiss
W. J. Weiss
TBT. J. Barrett
T. J. Barrett
CQChunyu Qiao
Chunyu Qiao
HTH. Todak
H. Todak
This paper proposes that the formation factor can be used in performance-based specifications as a fundamental measure of the transport properties of concrete. The formation factor can be measured using a concrete cylinder that is sealed until the age of testing and in either the sealed or fully saturated condition at the time of testing. The proposed method is rapid, easy to perform, fundamentally related to service life models, and is applicable to a wide range of binder compositions. The formation factor is defined herein as the ratio of the electrical resistivity of the bulk sample and the resistivity of the pore solution. The role of temperature, pore solution dilution, and moisture conditioning on the measured results is discussed. The paper then provides a relationship between the formation factor and service life for bridge decks and illustrates how this approach could be used for both a specification and for quality control/quality acceptance. It is recommended that the testing method be standardized, though the performance limits of the formation factor may be dependent on the type and geometry of the structure, the location of the structure, the exposure conditions, and the risk associated with damage to the structure.

28 May 2018 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
CQChunyu Qiao
Chunyu Qiao
PSPrannoy Suraneni
Prannoy Suraneni
MCMarisol Tsui Chang
Marisol Tsui Chang
JWJason Weiss
Jason Weiss