The common methods to detect zearalenone (ZEN) in edible oils need organic solvents to extract ZEN and then some sample purification process before detection, so, it is not convenient for on-site use. Here a simple method without organic solvents and a sample purification process was developed for the determination of ZEN in edible oils. The detection process only needs mixing oil with a surfactant solution in the indicated ratio and then loading the mixture onto a colloidal gold immunochromatographic (CGI) strip for detection. The optimized surfactant was AEO15 among the seven surfactants studied in this paper. The ZEN residue in edible oil could be quantitatively determined with a detection limit of 44.3 ng g−1, and the working range of the standard curve was from 50 to 800 ng g−1. This method has been successfully applied to the detection of ZEN in plant oils with recoveries ranging from 81 ± 7% to 129 ± 9% for spiked samples. The detection results for the ZEN residue in oil samples from a local market by this method were in good agreement with those obtained by the national standard method.
19 October 2020 in Journal of Solid State Electrochemistry
To produce a sensitive monoclonal antibody (mAb) for the simultaneous detection of carbofuran, benfuracarb, carbosulfan and 3-hydroxy-carbofuran, 2,3-dihydro-2,2-dimethyl-7-benzofuranmethanamine (DDB) was conjugated to bovine serum albumin (BSA) to prepare the immunogen DDB-BSA and mice were immunized. Coating antigens were prepared by conjugating DDB and 5-methoxy-2,3-dihydrobenzofuran-3-acetic acid (MDA) to BSA and ovalbumin (OVA), respectively. Furthermore, the effect of different antibody–antigen pairs on the sensitivity of ELISA and LFIA methods for the detection of carbofuran was investigated. After the immunization, a high-affinity mAb 13C8 was obtained. The ability of the coating antigen to compete with carbofuran for binding antibodies was found to be significantly different between ELISA and LFIA methods. With the antibody–antigen pair 13C8-MDA-OVA, the IC50 values of the ELISA and QD-LFIA methods for carbofuran were 0.18 ng/mL and 0.67 ng/mL, respectively. The cross-reactivity (CR) values of the two methods for benfuracarb, carbosulfan and 3-hydroxy-carbofuran ranged from 72.0% to 83.7%, while, for other carbamate pesticides, the CR values were less than 1%. The spiked recoveries of carbofuran in vegetables by the QD-LFIA method were 83–111%, with a coefficient of variation below 10%, and the test results of the actual samples were consistent with the HPLC-MS method. Overall, this study provides key materials for the development of immunoassays for carbofuran and its analogues, and the antibody–antigen pair selection strategy established in this study provides useful insights for the development of sensitive immunoassays for other compounds.
To establish rapid, high-sensitive, quantitative detection of ACP residues in vegetables. A 1G2 cell clone was selected as the most sensitive for anti-ACP antibody production following secondary immunization, cell fusion, and screening. The affinity of the 1G2 antibody to each of the four coating agents (imidacloprid–bovine serum albumin [BSA], thiacloprid–BSA, imidaclothiz–BSA, and ACP-BSA) was determined using a 20 min enzyme-linked immunosorbent assay (ELISA). The half maximal inhibitory concentration (IC50) was 0.51–0.62 ng/mL, showing no significant difference in affinity to different antigens. However, we obtained IC50 values of 0.58 and 1.40 ng/mL on the linear regression lines for 1G2 anti-ACP antibody/imidacloprid–BSA and 1G2 anti-ACP antibody/thiacloprid–BSA, respectively, via quantum dot (QD)-based immunochromatography. That is, the 1G2 antibody/imidacloprid–BSA pair (the best combination) was about three times more sensitive than the 1G2 antibody/thiacloprid–BSA pair in immunochromatographic detection. The best combination was used for the development of an 8 min chromatographic paper test. With simple and convenient sample pretreatment, we achieved an average recovery of 75–117%. The coefficient of variation (CoV) was <25% for all concentrations tested, the false–positive rate was <5%, the false–negative rate was 0%, and the linear range of the method was 50–1800 μg/kg. These performance metrics met the ACP detection standards in China, the European Union (EU), and the United States (US). In summary, in this study, we established an 8 min QD-based immunochromatographic stripe for the rapid and accurate quantitative determination of ACP residues in vegetables.