Linshan Xue

Dr. Linshan Xue

School of Microelectronics and Communication Engineering, Chongqing University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2021 in IEEE Communications Letters
Verified
Journal Article
Closed access
LXLinshan Xue
Linshan Xue
XLXue Li
Xue Li
WWWeiren Wu
Weiren Wu
ZZZhe Zhang
Zhe Zhang
HLHaitao Li
Haitao Li
For deep space exploration, a short-period pseudo noise (PN) ranging code cannot be applied due to the extremely large distances, whereas a long-period spread spectrum ranging code is also limited in application due to the long acquisition and tracking times. Under these circumstances, this letter proposes a parallel composite code upgrade from the traditional serial composite code. This proposed scheme can simplify the hardware structure and improve the unambiguous distance. The ranging method can complete unambiguous acquisition and tracking within 613674 km under the condition of an acquisition sensitivity of −156 dBm.

21 April 2020 in IEEE Access
Verified
Journal Article
Open access
LXLinshan Xue
Linshan Xue
WWWeiren Wu
Weiren Wu
XLXue Li
Xue Li
Very long baseline interferometry (VLBI) is widely used for astronomical observations and navigation of deep space receivers. To solve the problems of the downlink signal being excessively weak to be received and the excessively large acquisition time, a new VLBI measurement method based on the uplink signal is proposed. Deep space ground stations can provide radio measurement signals for deep space spacecraft via the uplink. The range, Doppler and VLBI can be determined by the spacecraft through signals from multiple ground stations. In this manner, a higher signal to noise ratio (SNR) can be obtained. This study involves the development of a prompt acquisition algorithm for high dynamic deep space signals. Furthermore, the measurement and tracking of the phases of multiple VLBI stations by deep space receiver employing the uplink are analyzed. The use of the algorithms reduce the acquisition time for deep space receiver, and high precision results can be obtained for the VLBI measurement. Compared with the traditional VLBI method, the ranging error on the same distance is effectively improved, and the angle measurement accuracy is better than delta differential one way ranging(ΔDOR). Because multiple spacecraft are not needed, there are fewer limitations than same beam interferometry (SBI).

3 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LXLinshan Xue
Linshan Xue
XLXue Li
Xue Li
WWWu Weiren
Wu Weiren
WLWang Lu
Wang Lu
ZJZhang Jianjun
Zhang Jianjun
In deep space telemetry tracking and command (TT&C) missions, the low signal-to-noise ratio (SNR) of the receiving signal restricts the improvement of measurement performance. In the paper, we adopt the uplink signal which transmitted by the ground station to achieve Very Long Baseline Interferometry (VLBI) in the spacecraft. Notably, this methodology guarantees an SNR enhancement of at least 30 dB compared to the downlink signal, marking a significant improvement. Considering the restrict of spacecraft calculate resources, we adopt multiple baselines to simplify the VLBI method in spacecraft receiver and obtain the high accuracy angle measurement results. The simulation and analysis show that the algorithm achieves a measurement accuracy of 0.77 nrad on the baseline length of 74 km, while the accuracy of traditional delta differential one-way ranging (ΔDOR) observations is 1 nrad with an 8400 km baseline length. In addition, we design a hardware platform for algorithm verification. This platform, under real-world conditions, exhibits an angle measurement error of less than 5 milliradians (mrad) even with a baseline length as short as 0.74 meters.

15 May 2026 in Measurement
Verified
Journal Article
Closed access
CWCaicheng Wang
Caicheng Wang
XLXue Li
Xue Li
LXLinshan Xue
Linshan Xue

11 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
YZYinsen Zhang
Yinsen Zhang
XLXue Li
Xue Li
LWLulu Wang
Lulu Wang
LXLinshan Xue
Linshan Xue
Compact direction-finding sensors are widely used in aerospace electronic systems, where antenna-element count, aperture, and receiver-channel resources are often constrained. In microwave phase interferometers, such constraints increase the sensitivity of ambiguity resolution to phase-tracking errors arising from hardware imperfections and adverse operating conditions. This paper proposes a prior-assisted ambiguity-resolution algorithm for a compact five-element L-shaped interferometer operating in an acquisition-to-tracking mode. After a coarse acquisition estimate places the target within the tracking gate, prior angle information and state prediction are incorporated into a unified spatiotemporal cost function to improve branch-selection reliability. The proposed method enhances ambiguity-resolution robustness without requiring additional antenna elements or receiver channels, thereby preserving the compact interferometer architecture. Simulation results demonstrate reliable ambiguity resolution with an angle-estimation RMSE of approximately 0.5° under severe phase-tracking errors with a standard deviation of 40°. Experimental results obtained using an 18-GHz hardware prototype with higher effective phase accuracy in both an anechoic chamber and outdoor path experiments further validate the effectiveness of the proposed method, achieving stable ambiguity resolution and an angle-estimation RMSE of approximately 0.05°.