Simin Huang

Prof. Simin Huang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2026 in Nature Reviews Chemistry
Verified
Journal Article
Closed access
PDF file
LYLiangtao Yang
Liangtao Yang
XYXingxing Yin
Xingxing Yin
JWJun Wang
Jun Wang
YSYanan Sun
Yanan Sun
YLYongchun Li
Yongchun Li
DZDong Zhou
Dong Zhou

19 August 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
YGYa Ge
Ya Ge
WYWeixing Yin
Weixing Yin
YLYousheng Lin
Yousheng Lin
KHKui He
Kui He
QHQing He
Qing He
SHSimin Huang
Simin Huang

6 September 2023 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
KHKui He
Kui He
ZZZhiling Zhang
Zhiling Zhang
LZLiangzhen Zhang
Liangzhen Zhang
WYWuzhi Yuan
Wuzhi Yuan
SHSimin Huang
Simin Huang

1 August 2013 in Applied Thermal Engineering
Verified
Journal Article
Closed access
SHSimin Huang
Simin Huang
FQFrank G.F. Qin
Frank G.F. Qin
MYMinlin Yang
Minlin Yang
XYXiaoxi Yang
Xiaoxi Yang
WZWen-Feng Zhong
Wen-Feng Zhong

18 August 2022 in Membranes
Verified
Journal Article
Open access
PDF file
NLNanfenng Li
Nanfenng Li
TZTao Zhong
Tao Zhong
LZLu Zhou
Lu Zhou
SHSimin Huang
Simin Huang
SZSi Zeng
Si Zeng
CLCaihang Liang
Caihang Liang
The applicability of a hollow fiber membrane evaporative cooler in hot–dry regions was investigated by experimental studies. To better understand the actual operating environment of the hollow fiber membrane evaporative cooler, the outdoor air design conditions for summer air conditioning in five cities were simulated by an enthalpy difference laboratory. Subsequently, the effects of water and air flow rates on outlet air parameters and performance parameters were investigated by setting-up a hollow fiber membrane evaporative cooling experimental rig. It was found that the hollow fiber membrane evaporative cooler has good application prospects in hot–dry regions such as Lanzhou, Xi’an, Yinchuan, Urumqi, and Karamay. Among them, the hollow fiber membrane evaporative cooler has higher applicability in regions with higher air temperatures and lower humidity such as Urumqi and Karamay. The results indicate that the air outlet temperature and relative humidity ranged from 26.5 °C to 30.8 °C and 63.5% to 82.8%, respectively. The outlet air temperature and relative humidity of the HFMEC can meet the thermal comfort requirements of hot–dry regions in the summer at an appropriate air flow rate. The maximum air temperature drop, wet-bulb efficiency, cooling capacity, and COP were 7.5 °C, 62.9%, 396.4 W, and 4.81, respectively. In addition, the effect of the air flow rate on the performance parameters was more significant than that of the water flow rate.

1 May 2017 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
SHSimin Huang
Simin Huang
MYMinlin Yang
Minlin Yang
ATAnd Jun-Ling Tu
And Jun-Ling Tu
YSYouyuan Shao
Youyuan Shao
YZYuanzhi Zuo
Yuanzhi Zuo