The association between stress and peptic ulcers has been questioned since the discovery of helicobacter pylori. This study examined whether high perceived everyday life stress was associated with an increased risk of either receiving a triple treatment or being diagnosed with a peptic ulcer. Cohen’s perceived stress scale measured the level of stress in a general health survey in 2010 of 17,525 residents of northern Jutland, Denmark, and was linked with National Danish registers on prescription drugs and hospital diagnoses. Cox proportional hazard regression was used to estimate the risk of either receiving a triple treatment or being diagnosed in a hospital with a peptic ulcer, in relation to quintiles of stress levels. A total of 121 peptic ulcer incidents were recorded within 33 months of follow-up. The lowest stress group had a cumulative incidence proportion of either receiving triple treatment or being diagnosed with peptic ulcer of approximately 0.4%, whereas the highest stress group had a cumulative incidence proportion of approximately 1.2%. Compared with that of the lowest stress group, those in the highest stress group had a 2.2-fold increase in risk of either receiving triple treatment or being diagnosed with peptic ulcer (HR 2.24; CI 95% 1.16:4.35) after adjustment for age, gender, socioeconomic status, non-steroid anti-inflammatory drug use, former ulcer and health behaviours. There was no difference in risk between the four least stressed quintiles. Subgroup analysis of diagnosed peptic ulcer patients revealed the same pattern as the main analysis, although the results were not significant. The highest level of perceived everyday life stress raised the risk of either receiving triple treatment or being diagnosed with peptic ulcer during the following 33 months more than twice compared with that of the lowest level of perceived stress.
Purpose: To investigate whether the prokinetic prucalopride increases the completion rate of colon capsule endoscopy (CCE). Secondary outcomes included demographic distribution, polyp detection rate (PDR), distribution of Leighton–Rex grade, and adverse events. Patients and Methods: In a nested cohort within the CareForColon2015 trial, a subgroup of 406 individuals underwent CCE in 2021. The first half (control) received the standard bowel preparation and the second half (prucalopride) was supplemented with 2 mg of prucalopride. Transit times and bowel preparations were analyzed and completion rates calculated as those having timely transit and acceptable bowel cleanliness. Major adverse events were recorded continuously and minor adverse events were quantified from questionnaires. Results: The group demographics were homogenous. The prevalence ratio for complete CCE was 1.32 (CI 95% 1.15; 1.53) in the prucalopride group compared to the control group. Completion rate was 74.9% in the prucalopride group and 56.7% in the control group. The proportions of acceptable bowel preparation and complete transits were higher in the prucalopride group. The mean CCE transit time was 2 hours and 8 minutes faster in the prucalopride group. The PDR was higher in the intervention group with 55.7% compared to 36.0% in the control group for polyps greater than 9 mm, whereas the groups’ PDRs were similar for small and diminutive polyps. In all, 589 polyps (mean 2.9) were found in the prucalopride group compared to 522 polyps (mean 2.6) in the control group. Conclusion: Prucalopride led to an increase in CCE completion rates. The proportions of complete transits and acceptable bowel preparations were higher in the prucalopride group. The PDR was higher in the prucalopride group compared to the control group. No major adverse events were identified. Nausea, diarrhea, headache and fatigue were more commonly reported in the prucalopride group.
Colon capsule endoscopy as an alternative to colonoscopy for the diagnosis of colonic disease may serve as a less invasive and more tolerable investigation for patients. Our aim was to examine patient-reported outcomes for colon capsule endoscopy compared to conventional optical colonoscopy including preference of investigation modality, tolerability and adverse events. A systematic literature search was conducted in Web of Science, PubMed and Embase. Search results were thoroughly screened for in- and exclusion criteria. Included studies underwent assessment of transparency and completeness, after which, data for meta-analysis were extracted. Pooled estimates of patient preference were calculated and heterogeneity was examined including univariate meta-regressions. Patient-reported tolerability and adverse events were reviewed. Out of fourteen included studies, twelve had investigated patient-reported outcomes in patients who had undergone both investigations, whereas in two the patients were randomized between investigations. Pooled patient preferences were estimated to be 52% (CI 95%: 41–63%) for colon capsule endoscopy and 45% (CI 95%: 33–57%) for conventional colonoscopy: not indicating a significant difference. Procedural adverse events were rarely reported by patients for either investigation. The tolerability was high for both colon capsule endoscopy and conventional colonoscopy. Patient preferences for conventional colonoscopy and colon capsule endoscopy were not significantly different. Procedural adverse events were rare and the tolerability for colon capsule endoscopy was consistently reported higher or equal to that of conventional colonoscopy.
1 August 2020 in United European Gastroenterology Journal
Background: Guidelines suggest computed tomography colonography (CTC) following incomplete optical colonoscopy (OC). Colon capsule endoscopies (CCE) have been suggested as an alternative, although completion rates have been unsatisfactory. Introduction of artificial intelligence (AI)‐based localization algorithms of the camera capsules may enable identification of incomplete CCE investigations overlapping with incomplete OCs.Objective: The study aims to investigate relative sensitivity of CCE compared with CTC following incomplete OC, investigate the completion rate when combining results from the incomplete OC and CCE, and develop a forward‐tracking algorithm ensuring a safe completeness of combined investigations.Methods: In this prospective paired study, patients with indication for CTC following incomplete OC were included for CCE and CTC. Location of CCE abortion and OC abortion were registered to identify complete combined investigations. AI‐based algorithm for localization of capsules were developed reconstructing the passage of the colon.Results: In 237 individuals with CTC indication; 105 were included, of which 97 underwent both a CCE and CTC. CCE was complete in 66 (68%). Including CCEs which reached most oral point of incomplete OC, 73 (75%) had complete colonic investigations; 78 (80%) had conclusive investigations. Relative sensitivity of CCE compared with CTC was 2.67 (95% confidence interval (CI) 1.76;4.04) for polyps >5 mm and 1.91 (95% CI 1.18;3.09) for polyps >9 mm. An AI‐based algorithm was developed.Conclusion: Sensitivity of CCE following incomplete OC was superior to CTC. Introducing and improving algorithm‐based localization of capsule abortion may increase identification of overall complete investigation rates following incomplete OC.ClinicalTrials.gov identifier: NCT02826993
Video-capsule endoscopy (VCE) reading is a time- and energy-consuming task. Agreement on findings between readers (either different or the same) is a crucial point for increasing performance and providing valid reports. The aim of this systematic review with meta-analysis is to provide an evaluation of inter/intra-observer agreement in VCE reading. A systematic literature search in PubMed, Embase and Web of Science was performed throughout September 2022. The degree of observer agreement, expressed with different test statistics, was extracted. As different statistics are not directly comparable, our analyses were stratified by type of test statistics, dividing them in groups of “None/Poor/Minimal”, “Moderate/Weak/Fair”, “Good/Excellent/Strong” and “Perfect/Almost perfect” to report the proportions of each. In total, 60 studies were included in the analysis, with a total of 579 comparisons. The quality of included studies, assessed with the MINORS score, was sufficient in 52/60 studies. The most common test statistics were the Kappa statistics for categorical outcomes (424 comparisons) and the intra-class correlation coefficient (ICC) for continuous outcomes (73 comparisons). In the overall comparison of inter-observer agreement, only 23% were evaluated as “good” or “perfect”; for intra-observer agreement, this was the case in 36%. Sources of heterogeneity (high, I2 81.8–98.1%) were investigated with meta-regressions, showing a possible role of country, capsule type and year of publication in Kappa inter-observer agreement. VCE reading suffers from substantial heterogeneity and sub-optimal agreement in both inter- and intra-observer evaluation. Artificial-intelligence-based tools and the adoption of a unified terminology may progressively enhance levels of agreement in VCE reading.