Electrostimulation and electroactive scaffolds can positively influence and guide cellular behaviour and thus has been garnering interest as a key tissue engineering strategy. The development of conducting polymers such as polyaniline enables the fabrication of conductive polymeric composite scaffolds. In this study, we report on the initial development of a polycaprolactone scaffold incorporating different weight loadings of a polyaniline microparticle filler. The scaffolds are fabricated using screw-assisted extrusion-based 3D printing and are characterised for their morphological, mechanical, conductivity, and preliminary biological properties. The conductivity of the polycaprolactone scaffolds increases with the inclusion of polyaniline. The in vitro cytocompatibility of the scaffolds was assessed using human adipose-derived stem cells to determine cell viability and proliferation up to 21 days. A cytotoxicity threshold was reached at 1% wt. polyaniline loading. Scaffolds with 0.1% wt. polyaniline showed suitable compressive strength (6.45 ± 0.16 MPa) and conductivity (2.46 ± 0.65 × 10−4 S/cm) for bone tissue engineering applications and demonstrated the highest cell viability at day 1 (88%) with cytocompatibility for up to 21 days in cell culture.
31 August 2017 in Journal of Engineering and Technological Sciences
There has been a steady increase in traffic accidents with major injuries in Indonesia over the last 10 years, especially those with a score higher than 3 on the Abbreviated Injury Scale (AIS). Frontal, side, and rear collisions, as well as pedestrian impact are modes of accident that contribute to the majority of injuries or fatalities. Based on age classification, the 16-30 age group are the most vulnerable road users in Indonesia. Traffic accidents in Indonesia are dominated by motorcycles, which also contribute the highest portion of fatalities and major injuries (AIS score > 3). Most traffic accidents can be attributed to human, road and environmental, or vehicle factors. Careless driving and unruly behavior of the driver are the main causes of accidents in Indonesia. Statistical data and analyses on traffic accidents in Indonesia can be used to develop a comprehensive strategy and policy to reduce the number of fatalities and severe injuries of road accidents in Indonesia. There is a need to balance the high growth of motor vehicles with adequate infrastructure. Good driver education as well as vehicle safety and crashworthiness regulations are required in order to reduce traffic accident fatalities.
In the present study, frontal crash simulations were conducted to determine the effect of various car speeds against the Head Injury Criterion (HIC), a measure of the likelihood of head injury arising from impact. The frontal impact safety of ITB's formula SAE race car designed by students was evaluated as a case study. LS-DYNA®, an explicit finite element code for non-linear dynamic analysis was utilized in the analysis. To analyze head injury, a two-step simulation was conducted. In the first step, a full-frontal barrier test was simulated without incorporating a dummy inside the car. The output was the deceleration data of the car, which was used as input in the second step, a sled test simulation. In the sled test, only the cockpit and dummy were modeled. The effect of deceleration to the head of the dummy was then evaluated. The results show that HIC values at an impact speed of 7 m/s (25 km/h) to 11 m/s (40 km/h) were below the safe limit and still in the safe zone. However, the HIC values will exceed the safe limit when the speed of impact is the same as or greater than 12 m/s (43 km/h).
This work presents the development of an optical motion-capture system for 3D gait analysis. The system consists of two video cameras with speed of 25 fps, flash lighter, LED markers, and two PCs and technical computing software, which are used to acquire marker motion attached to human body during walking. The developed system has five module to obtain real coordinate of markers, i.e. pre-processing, camera calibration, marker detection and tracking, 3D reconstruction, and post-processing module. In the experiment, two camcorders are synchronized using flashlight. The recorded videos from experiment are extracted into frames. The synchronized framesare converted into binary images and marker position can be detected and tracked using least distance method. 3D Direct Linear Transformation method has been used to reconstruct 3D marker position in real coordinate. The marker positions data obtained from experiment could then be used for further kinematics and kinetics analysis of human gait.
Backgrounds: In this research, we want to find out whether extracellular vesicles (EVs) from adipose-derived mesenchymal stem cells (MSCs) can improve ligament–bone integration after primary Anterior Cruciate Ligament (ACL) repair by performing immunological and biomechanical tests. Methods: All of the rabbits underwent ACL resection at the proximal attachment to the femur bone, and then were divided into four groups. We performed an ELISA examination from the tissue at the bone–ligament interface of iNOS, CD206, MMP-3, and TIMP-1 to evaluate their levels at the inflammatory stage at the end of the first week. Immunoexpression of type I and III collagen and failure load biomechanical tests were performed at the end of the sixth week. Result: The group that underwent ACL repair with EVs augmentation had significantly higher levels of CD206, significantly lower MMP-3 levels, and significantly higher TIMP-1 levels in the first week. The iNOS levels in the group that underwent ACL repair with EVs augmentation were significantly different compared to the control group that did not receive any. The number of type I collagen fibers and the failure load levels in the group that underwent ACL repair with EVs augmentation were significantly higher. Conclusions: EVs from adipose-derived MSCs can improve the outcome of primary ACL repair in rabbits by regulating the inflammatory process during the healing period.