Matous Cejnek

Mr. Matous Cejnek

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2021 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
MCMatous Cejnek
Matous Cejnek
OVOldřich Vyšata
Oldřich Vyšata
MVMartin Valis
Martin Valis
IBIvo Bukovsky
Ivo Bukovsky
Alzheimer’s disease is diagnosed via means of daily activity assessment. The EEG recording evaluation is a supporting tool that can assist the practitioner to recognize the illness, especially in the early stages. This paper presents a new approach for detecting Alzheimer’s disease and potentially mild cognitive impairment according to the measured EEG records. The proposed method evaluates the amount of novelty in the EEG signal as a feature for EEG record classification. The novelty is measured from the parameters of EEG signal adaptive filtration. A linear neuron with gradient descent adaptation was used as the filter in predictive settings. The extracted feature (novelty measure) is later classified to obtain Alzheimer’s disease diagnosis. The proposed approach was cross-validated on a dataset containing EEG records of 59 patients suffering from Alzheimer’s disease; seven patients with mild cognitive impairment (MCI) and 102 controls. The results of cross-validation yield 90.73% specificity and 89.51% sensitivity. The proposed method of feature extraction from EEG is completely new and can be used with any classifier for the diagnosis of Alzheimer’s disease from EEG records.

1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
IBIvo Bukovsky
Ivo Bukovsky
NHNoriyasu Homma
Noriyasu Homma
KIKei Ichiji
Kei Ichiji
MCMatous Cejnek
Matous Cejnek
MSMatous Slama
Matous Slama
JBJiri Bila
Jiri Bila
During radiotherapy treatment for thoracic and abdomen cancers, for example, lung cancers, respiratory motion moves the target tumor and thus badly affects the accuracy of radiation dose delivery into the target. A real-time image-guided technique can be used to monitor such lung tumor motion for accurate dose delivery, but the system latency up to several hundred milliseconds for repositioning the radiation beam also affects the accuracy. In order to compensate the latency, neural network prediction technique with real-time retraining can be used. We have investigated real-time prediction of 3D time series of lung tumor motion on a classical linear model, perceptron model, and on a class of higher-order neural network model that has more attractive attributes regarding its optimization convergence and computational efficiency. The implemented static feed-forward neural architectures are compared when using gradient descent adaptation and primarily the Levenberg-Marquardt batch algorithm as the ones of the most common and most comprehensible learning algorithms. The proposed technique resulted in fast real-time retraining, so the total computational time on a PC platform was equal to or even less than the real treatment time. For one-second prediction horizon, the proposed techniques achieved accuracy less than one millimeter of 3D mean absolute error in one hundred seconds of total treatment time.

1 October 2018 in Neurocomputing
Verified
Journal Article
Closed access
MCMatous Cejnek
Matous Cejnek
IBIvo Bukovsky
Ivo Bukovsky

30 August 2021 in Entropy
Verified
Journal Article
Open access
PDF file
JVJan Vrba
Jan Vrba
MCMatous Cejnek
Matous Cejnek
JSJakub Steinbach
Jakub Steinbach
ZKZuzana Krbcova
Zuzana Krbcova
This study proposes a fully automated gearbox fault diagnosis approach that does not require knowledge about the specific gearbox construction and its load. The proposed approach is based on evaluating an adaptive filter’s prediction error. The obtained prediction error’s standard deviation is further processed with a support-vector machine to classify the gearbox’s condition. The proposed method was cross-validated on a public dataset, segmented into 1760 test samples, against two other reference methods. The accuracy achieved by the proposed method was better than the accuracies of the reference methods. The accuracy of the proposed method was on average 9% higher compared to both reference methods for different support vector settings.

21 October 2022 in Journal of Computational Science
Verified
Journal Article
Closed access
MCMatous Cejnek
Matous Cejnek
JVJan Vrba
Jan Vrba

21 February 2014
Verified
Conference Paper
Closed access
PBPeter Mark Benes
Peter Mark Benes
MCMatous Cejnek
Matous Cejnek
Jan KalivodaJan Kalivoda
Jan Kalivoda
IBIvo Bukovsky
Ivo Bukovsky