Sami Bennour

Prof. Dr. Sami Bennour

Mechanical Laboratory of Sousse, National Engineering School of Sousse, University of Sousse, Tunisia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
BSBAKLOUTI Souha
BAKLOUTI Souha
ACAbdelbadia Chaker
Abdelbadia Chaker
TRTaysir REZGUI
Taysir REZGUI
Anis SahbaniAnis Sahbani
Anis Sahbani
Sami BennourSami Bennour
Sami Bennour
Med amine LaribiMed amine Laribi
Med amine Laribi
This study introduces a novel wearable Inertial Measurement Unit (IMU)-based system for an objective and comprehensive assessment of Work-Related Musculoskeletal Disorders (WMSDs), thus enhancing workplace safety. The system integrates wearable technology with a user-friendly interface, providing magnetometer-free orientation estimation, joint angle measurements, and WMSDs risk evaluation. Tested in a cable manufacturing facility, the system was evaluated with ten female employees. The evaluation involved work cycle identification, inter-subject comparisons, and benchmarking against standard WMSD risk assessments like RULA, REBA, Strain Index, and Rodgers Muscle Fatigue Analysis. The evaluation demonstrated uniform joint patterns across participants (ICC=0.72±0.23) and revealed a higher occurrence of postures warranting further investigation, which is not easily detected by traditional methods such as RULA. The experimental results showed that the proposed system’s risk assessments closely aligned with the established methods and enabled detailed and targeted risk assessments, pinpointing specific bodily areas for immediate ergonomic interventions. This approach not only enhances the detection of ergonomic risks but also supports the development of personalized intervention strategies, addressing common workplace issues such as tendinitis, low back pain, and carpal tunnel syndrome. The outcomes highlight the system’s sensitivity and specificity in identifying ergonomic hazards. Future efforts should focus on broader validation and exploring the relative influence of various WMSDs risk factors to refine risk assessment and intervention strategies for improved applicability in occupational health.

1 January 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
Sami BennourSami Bennour
Sami Bennour
BUBaptiste Ulrich
Baptiste Ulrich
TLThomas Legrand
Thomas Legrand
BJBrigitte M. Jolles
Brigitte M. Jolles
JFJulien Favre
Julien Favre

17 February 2016 in Advanced Robotics
Verified
Journal Article
Closed access
HLHoussein Lamine
Houssein Lamine
Sami BennourSami Bennour
Sami Bennour
LRLotfi Romdhane
Lotfi Romdhane
In this paper, we present a method, based on interval analysis, to solve the problem of designing cable-driven parallel manipulators (CDPMs) for a desired workspace. The constraint of having positive cable tensions ensuring the equilibrium of the platform has to be satisfied within the given workspace. The proposed algorithm is based on interval analysis, which covers the entire workspace and hence guarantees a singularity-free workspace. Furthermore, the algorithm is capable of finding all possible solutions for this problem and an optimal one is selected according to the user-defined criterion. Two examples are selected to show the efficiency of the developed algorithm in solving this complex problem. The first one deals with the design of a planar CDPM and the second one considers a spatial CDPM. In both cases, the algorithm succeeded to find all possible designs from which the designer can select a solution that fits best his application.

15 May 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
SEShannon Edd
Shannon Edd
Sami BennourSami Bennour
Sami Bennour
BUBaptiste Ulrich-Ischer
Baptiste Ulrich-Ischer
BJBrigitte M. Jolles
Brigitte M. Jolles
JFJulien Favre
Julien Favre
The purpose of this study was to determine the effects of modifying stride length (SL) on knee adduction and flexion moments, two markers of knee loading associated with medial-compartment knee osteoarthritis (OA) progression. This study also tested if SL modifications, in addition to foot progression angle (FP) and step width (SW) modifications, provide solutions in more subjects for reducing knee adduction moment (KAM) without increasing knee flexion moment (KFM), potentially protecting the joint. Fourteen healthy subjects (six female) were enrolled in this preliminary study. Walking trials were collected first without instructions, and then following foot placement instructions for 50 combinations of SL, FP, and SW modifications. Repeated measures analysis of variance was used to detect group-average effects of footprint modifications on maximum KAM and KFM and on KAM impulse. Subject-specific dose–responses between footprint modifications and kinetics changes were modeled with linear regressions, and the models were used to identify modification solutions, per subject, for various kinetics change conditions. Shorter SL significantly decreased the three kinetics measures (p < 0.01). Potential solutions for 10% reductions in maximum KAM and KAM impulse without increasing maximum KFM were identified for five subjects with FP and SW modifications. A significantly higher proportion of subjects had solutions when adding SL modifications (11 subjects, p = 0.04). In conclusion, SL is a valuable parameter to modify, especially in combination with FP and SW modifications, to reduce markers of medial knee loading. Future work is needed to extend these findings to osteoarthritic knees.

18 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FEFerdaws Ennaiem
Ferdaws Ennaiem
ACAbdelbadia Chaker
Abdelbadia Chaker
Med amine LaribiMed amine Laribi
Med amine Laribi
Juan SandovalJuan Sandoval
Juan Sandoval
Sami BennourSami Bennour
Sami Bennour
Saïd ZeghloulSaïd Zeghloul
Saïd Zeghloul
This paper deals with the optimal design of a planar cable-driven parallel robot (CDPR), with three degrees of freedom, intended for assisting the patient’s affected upper limb along a prescribed movement. A Qualisys motion capture system was used to record the prescribed task performed by a healthy subject. For each pose taken by the center of mass of the end-effector, the cable tensions, the elastic stiffness and the dexterity were optimized while satisfying a set of constraints. First, a multiobjective formulation of the optimization problem was adopted. Since selecting a single solution among the multiple ones given by the Pareto front presents an issue, a mono-objective formulation was chosen, where the objective function was defined as a weighted sum of the chosen criteria. The appropriate values of the weighted coefficients were studied with the aim of identifying their influence on the optimization process and, thus, a judicious choice was made. A prototype of the optimal design of the CDPR was developed and validated experimentally on the prescribed workspace using the position control approach for the motors. The tests showed promising reliability of the proposed design for the task.

31 December 2020 in Robotics
Verified
Journal Article
Open access
PDF file
FEFerdaws Ennaiem
Ferdaws Ennaiem
ACAbdelbadia Chaker
Abdelbadia Chaker
Juan SandovalJuan Sandoval
Juan Sandoval
Med amine LaribiMed amine Laribi
Med amine Laribi
Sami BennourSami Bennour
Sami Bennour
Saïd ZeghloulSaïd Zeghloul
Saïd Zeghloul
This paper deals with the design of an optimal cable-driven parallel robot (CDPR) for upper limb rehabilitation. The robot’s prescribed workspace is identified with the help of an occupational therapist based on three selected daily life activities, which are tracked using a Qualisys motion capture system. A preliminary architecture of the robot is proposed based on the analysis of the tracked trajectories of all the activities. A multi-objective optimization process using the genetic algorithm method is then performed, where the cable tensions and the robot size are selected as the objective functions to be minimized. The cables tensions are bounded between two limits, where the lower limit ensures a positive tension in the cables at all times and the upper limit represents the maximum torque of the motor. A sensitivity analysis is then performed using the Monte Carlo method to yield the optimal design selected out of the non-dominated solutions, forming the obtained Pareto front. The robot with the highest robustness toward the disturbances is identified, and its dexterity and elastic stiffness are calculated to investigate its performance.