Antonio Contreras

Dr. Antonio Contreras

Instituto Mexicano del Petroleo
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Materials & Design (1980-2015)
Verified
Journal Article
Closed access
Antonio ContrerasAntonio Contreras
Antonio Contreras
SHS.L. Hernández
S.L. Hernández
Ricardo Orozco-CruzRicardo Orozco-Cruz
Ricardo Orozco-Cruz
Ricardo Galvan-MartinezRicardo Galvan-Martinez
Ricardo Galvan-Martinez

1 June 2012 in Materials & Design (1980-2015)
Verified
Journal Article
Closed access
EBE. Bedolla
E. Bedolla
JLJ. Lemus-Ruiz
J. Lemus-Ruiz
Antonio ContrerasAntonio Contreras
Antonio Contreras

1 September 2013 in Materials & Design (1980-2015)
Verified
Journal Article
Closed access
JAJ.L. Alamilla
J.L. Alamilla
ESE. Sosa
E. Sosa
CSC.A. Sánchez-Magaña
C.A. Sánchez-Magaña
RAR. Andrade-Valencia
R. Andrade-Valencia
Antonio ContrerasAntonio Contreras
Antonio Contreras

1 January 2018
Verified
Book
Closed access
Antonio ContrerasAntonio Contreras
Antonio Contreras
EBEgberto Bedolla Becerril
Egberto Bedolla Becerril
MMMelchor Salazar Martínez
Melchor Salazar Martínez
JRJosé Lemus Ruiz
José Lemus Ruiz

1 July 2007 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
Antonio ContrerasAntonio Contreras
Antonio Contreras

31 August 2017 in Materials Research
Verified
Journal Article
Open access
PDF file
Antonio ContrerasAntonio Contreras
Antonio Contreras
MSMelchor Salazar
Melchor Salazar
ACAndres Carmona
Andres Carmona
Ricardo Galvan-MartinezRicardo Galvan-Martinez
Ricardo Galvan-Martinez
In the last years, electrochemical noise (EN) has demonstrate that is capable of detect the initiation of cracks during the slow strain rate tests (SSRT). In this research, EN has been used as a tool to detect stress corrosion cracking (SCC) in low carbon steel (X52) exposed to a synthetic soil solution called NS4 at room temperature with pH of 5, 8 and 10. The electrochemical potential and current noise were measured simultaneously during SSRT. Relation between EN and SCC process was analyzed. EN readings of current consisted of transients with high intensity and frequency during all SSRT tests. EN readings of potential at the maximum strength (UTS) and before fracture, increase intensity and amplitude of the transients, attributed to beginning of cracking. Localized index (LI) values indicate a mix corrosion type (general and localized corrosion) during SSRT tests. According to SCC index obtained from mechanical properties, it is clear that X52 steel has low SCC susceptibility. Scanning electron microscopy (SEM) observations were carried out in the fracture surface and longitudinal sections. The specimens tested in NS4 solution with pH 5 were the most likely to present SCC, additionally in this condition a brittle fracture with transgranular appearance was observed.