Stuart Adam Callary

Dr. Stuart Adam Callary

Royal Adelaide Hospital, Adelaide, South Australia
+1
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2006 in Biomaterials
Verified
Journal Article
Closed access
CHChristopher A. Holding
Christopher A. Holding
DFDavid M. Findlay
David M. Findlay
RSRoumen Stamenkov
Roumen Stamenkov
SNSusan D. Neale
Susan D. Neale
HLHelen Lucas
Helen Lucas
DHDavid R. Haynes
David R. Haynes

13 December 2009 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
DCDavid Campbell
David Campbell
GMGraham Mercer
Graham Mercer
KNKjell G. Nilsson
Kjell G. Nilsson
VWVanessa Wells
Vanessa Wells
JFJohn R. Field
John R. Field
Stuart Adam CallaryStuart Adam Callary
Stuart Adam Callary
Measurement of early stem subsidence can be used to predict the likelihood of long-term femoral component loosening and clinical failure. Data that examines the early migration pattern of clinically proven stems will provide clinicians with useful baseline data with which to compare new stem designs. This study was performed to evaluate the early migration pattern of a hydroxyapatite-coated press-fit femoral component that has been in use for over ten years. We enrolled 30 patients who underwent THA for osteoarthritis. The median age was 70 years (range, 55–80 years). Patients were clinically assessed using the Harris hip score. Radiostereometric analysis was used to evaluate stem migration at three to four days, six months, one year and two years. We observed a mean subsidence of 0.73 mm at six months, 0.62 mm at one year and 0.58 mm at two years and a mean retroversion of 1.82° at six months, 1.90° at one year and 1.59° at two years. This data suggests that subsidence is confined to the first six months after which there was no further subsidence. The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs.

1 September 2010 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
Lucian Bogdan SolomonLucian Bogdan Solomon
Lucian Bogdan Solomon
YLY. C. Lee
Y. C. Lee
Stuart Adam CallaryStuart Adam Callary
Stuart Adam Callary
MBM. Beck
M. Beck
DHD. W. Howie
D. W. Howie
We dissected 20 cadaver hips in order to investigate the anatomy and excursion of the trochanteric muscles in relation to the posterior approach for total hip replacement. String models of each muscle were created and their excursion measured while the femur was moved between its anatomical position and the dislocated position. The position of the hip was determined by computer navigation. In contrast to previous studies which showed a separate insertion of piriformis and obturator internus, our findings indicated that piriformis inserted onto the superior and anterior margins of the greater trochanter through a conjoint tendon with obturator internus, and had connections to gluteus medius posteriorly. Division of these connections allowed lateral mobilisation of gluteus medius with minimal retraction. Analysis of the excursion of these muscles revealed that positioning the thigh for preparation of the femur through this approach elongated piriformis to a maximum of 182%, obturator internus to 185% and obturator externus to 220% of their resting lengths, which are above the thresholds for rupture of these muscles. Our findings suggested that gluteus medius may be protected from overstretching by release of its connection with the conjoint tendon. In addition, failure to detach piriformis or the obturators during a posterior approach for total hip replacement could potentially produce damage to these muscles because of over-stretching, obturator externus being the most vulnerable.

30 May 2024 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
BKBart L Kaptein
Bart L Kaptein
BPBart Pijls
Bart Pijls
LKLennard Koster
Lennard Koster
JKJohan Kärrholm
Johan Kärrholm
MHMaury Hull
Maury Hull
Maiken StillingMaiken Stilling
Maiken Stilling
Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and consistent in execution, presentation, reporting, and interpretation. Both authors and reviewers of scientific papers using RSA may use these guidelines, summarized in the Checklist, as a reference. Deviations from these guidelines should have the underlying rationale stated.

12 October 2014 in Anz Journal of Surgery
Verified
Journal Article
Closed access
PDF file
Lucian Bogdan SolomonLucian Bogdan Solomon
Lucian Bogdan Solomon
SHSaleem M. Hussenbocus
Saleem M. Hussenbocus
TCTania A. Carbone
Tania A. Carbone
Stuart Adam CallaryStuart Adam Callary
Stuart Adam Callary
DHDonald W. Howie
Donald W. Howie

10 October 2014 in Acta Orthopaedica
Verified
Journal Article
Open access
Stuart Adam CallaryStuart Adam Callary
Stuart Adam Callary
Lucian Bogdan SolomonLucian Bogdan Solomon
Lucian Bogdan Solomon
OHOksana T Holubowycz
Oksana T Holubowycz
DCDavid G Campbell
David G Campbell
ZMZachary Munn
Zachary Munn
DHDonald W Howie
Donald W Howie
Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2-10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear.