Alberto Vallan

Dr. Alberto Vallan

Politecnico di Torino, Department of Electronics and Telecommunications, corso Duca degli Abruzzi, 24, I-10129 Torino, Italy
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RGRiccardo Gassino
Riccardo Gassino
GPGuido Perrone
Guido Perrone
Alberto VallanAlberto Vallan
Alberto Vallan
Fiber optics is the elective technology for sensing temperatures in harsh environments. Among the possible exploitable working principles, fiber Bragg gratings are the most widespread implementation for their excellent balance between system complexity and performance. However, despite they are well known and established, so far metrological investigations have been limited to cases in which the sensor is used in uniform temperature conditions. This paper analyzes the response of commercial fiber Bragg gratings employed as temperature sensors in applications that imply large temperature gradients, such as in laser based thermal treatments of solid tumors. A theoretical model of the sensor is implemented first and then used to evaluate its response in non-uniform temperature distributions. The model results are experimentally validated by means of a liver phantom and comparisons between different grating configurations, such as single or multiplexed with different lengths, are made.

1 December 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MOMassimo Olivero
Massimo Olivero
Alberto VallanAlberto Vallan
Alberto Vallan
RORenato Orta
Renato Orta
GPGuido Perrone
Guido Perrone
This paper reviews some aspects of optical fiber sensors based on a single-mode (SM)-multimode (MM)-SM structure and reports on the realization of temperature sensors in which the MM section is made by a quasi-two mode fiber. Two different realizations are compared that rely on: 1) a bend-insensitive fiber operated in the second optical communication window and 2) an SM fiber at $2 \mu$m operated in the third optical communication window. The performances of the sensors are compared with those of similar structures that exploit largely MM sections.

30 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Sabrina GrassiniSabrina Grassini
Sabrina Grassini
MIMaen Ishtaiwi
Maen Ishtaiwi
MPMarco Parvis
Marco Parvis
Alberto VallanAlberto Vallan
Alberto Vallan
This paper describes an approach to develop and deploy low-cost plastic optical fiber sensors suitable for measuring low concentrations of pollutants in the atmosphere. The sensors are designed by depositing onto the exposed core of a plastic fiber thin films of sensitive compounds via either plasma sputtering or via plasma-enhanced chemical vapor deposition (PECVD). The interaction between the deposited layer and the gas alters the fiber’s capability to transmit the light, so that the sensor can simply be realized with a few centimeters of fiber, an LED and a photodiode. Sensors arranged in this way exhibit several advantages in comparison to electrochemical and optical conventional sensors; in particular, they have an extremely low cost and can be easily designed to have an integral, i.e., cumulative, response. The paper describes the sensor design, the preparation procedure and two examples of sensor prototypes that exploit a cumulative response. One sensor is designed for monitoring indoor atmospheres for cultural heritage applications and the other for detecting the presence of particular gas species inside the RPC (resistive plate chamber) muon detector of the Compact Muon Solenoid (CMS) experiment at CERN in Geneva.

21 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
VRVincenzo Randazzo
Vincenzo Randazzo
EPEdoardo Puleo
Edoardo Puleo
APAnnunziata Paviglianiti
Annunziata Paviglianiti
Alberto VallanAlberto Vallan
Alberto Vallan
Eros PaseroEros Pasero
Eros Pasero
The electrocardiogram (ECG) signal describes the heart’s electrical activity, allowing it to detect several health conditions, including cardiac system abnormalities and dysfunctions. Nowadays, most patient medical records are still paper-based, especially those made in past decades. The importance of collecting digitized ECGs is twofold: firstly, all medical applications can be easily implemented with an engineering approach if the ECGs are treated as signals; secondly, paper ECGs can deteriorate over time, therefore a correct evaluation of the patient’s clinical evolution is not always guaranteed. The goal of this paper is the realization of an automatic conversion algorithm from paper-based ECGs (images) to digital ECG signals. The algorithm involves a digitization process tested on an image set of 16 subjects, also with pathologies. The quantitative analysis of the digitization method is carried out by evaluating the repeatability and reproducibility of the algorithm. The digitization accuracy is evaluated both on the entire signal and on six ECG time parameters (R-R peak distance, QRS complex duration, QT interval, PQ interval, P-wave duration, and heart rate). Results demonstrate the algorithm efficiency has an average Pearson correlation coefficient of 0.94 and measurement errors of the ECG time parameters are always less than 1 mm. Due to the promising experimental results, the algorithm could be embedded into a graphical interface, becoming a measurement and collection tool for cardiologists.

1 August 2012 in Measurement
Verified
Journal Article
Closed access
ACAlessio Carullo
Alessio Carullo
Alberto VallanAlberto Vallan
Alberto Vallan

26 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MOMassimo Olivero
Massimo Olivero
AMAlessandro Mirigaldi
Alessandro Mirigaldi
VSValentina Serafini
Valentina Serafini
Alberto VallanAlberto Vallan
Alberto Vallan
GPGuido Perrone
Guido Perrone
Daniele TosiDaniele Tosi
Daniele Tosi
This article reports on the first demonstration of in situ , real-time dosimetry realized with an enhanced backscattering optical fiber, and a high-resolution optical backscattering reflectometry measurement. This work is devised to overcome the current problems in monitoring radiotherapy treatments, in particular, the difficult evaluation of not only the actual X-ray dose that is accumulated on the target volume but also the distribution profile of the ionizing radiation beam. Overall, the research aims at developing a dose sensor with the most demanding features of small form factor, spatial profiling, and remote interrogation. The experiments have been conducted by evaluating the spatial profile of radiation-induced spectral shift of the Rayleigh backscattering along an optical fiber exposed to X-rays. The sensing element is a section of specialty optical fiber whose Rayleigh backscattering signature changes under ionizing radiation. The specialty fiber is designed to exhibit an enhanced backscattering, in order to overcome the poor sensitivity to radiation of standard optical fibers that are normally, used in telecommunications. The enhanced sensitivity is achieved by doping the core with either aluminum or magnesium nanoparticles, and two different fibers have been fabricated and tested. The experimental results show the capability of real time detection of the radiation profile from high-dose rates (700 Gy/min) to low-dose rates (2 Gy/min). Moreover, different sensing mechanisms and responses to high- and low-dose rates are evidenced. A comparison with a quasi-distributed sensing system based on an array of fiber Bragg gratings (FBGs) is discussed, highlighting the superior performance of the backscattering approach in terms of sensitivity and spatial resolution, whereas the array of FBGs exhibits an advantage in terms of sampling speed.