Priyabrata Shaw

Dr. Priyabrata Shaw

General Electric, Greenville, South Carolina, USA
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SSSaurabh Shukla
Saurabh Shukla
BSBhim Pratap Singh
Bhim Pratap Singh
Priyabrata ShawPriyabrata Shaw
Priyabrata Shaw
Ahmed Al-DurraAhmed Al-Durra
Ahmed Al-Durra
TETarek H. M. El-Fouly
Tarek H. M. El-Fouly
Ehab El-SaadanyEhab El-Saadany
Ehab El-Saadany
In this article, an analytical method is presented to achieve maximum power point tracking (MPPT) for a solar photovoltaic (PV) array-based water pumping system comprising of an induction motor drive (IMD). The gating signals are generated using the space vector pulsewidth modulation (SVPWM) method for three-phase inverter. This analytical MPPT control (AMPPTC) scheme exhibits fast dynamic performance and minimum overshoot with the IMD-based water pumping system. Additionally, the AMPPTC scheme provides absolute steady-state robustness under variations in solar irradiance/parameters that improves the stability of the system under a wide speed range of IMD and makes the system insensitive toward parameter variations. The dc-link voltage regulation is assured by three-phase inverter, and MPPT regulation is achieved by the boost converter. This two-stage PV system, with MPPT controlled boost converter and SVPWM-based three-phase inverter operating the pump, is modeled and simulated in Simulink environment of MATLAB. The performance and robustness of the AMPPTC-based PV water pumping system are corroborated through the laboratory experimentation.

7 June 2019 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
Priyabrata ShawPriyabrata Shaw
Priyabrata Shaw
Nowadays, the research is being devoted to the development of rapid and precise maximum power point tracking (MPPT) for various photovoltaic (PV) applications. However, the constraints imposed by size, cost, efficiency, and tracking performances essentially limit the application of conventional MPPT techniques and their analysis methodologies. This study recommends a fast and robust analogue PV MPPT for the battery charging system using dc–dc boost converter. The fast dynamic performances with absolute robustness are ensured here by fast‐scale stability analysis of actually switched boost converter using the concepts based on non‐linear dynamics and bifurcation theory. Such concepts not only provide the information to design an efficient MPPT system under rapidly changing environmental conditions but also guarantee the system to operate either in period‐1 or chaotic mode. The theoretical and mathematical analyses are experimentally verified using a prototype PV battery charging system utilising dc–dc boost converter. It is presented that operating the MPPT system in chaos not only yields the broader power spectrum with reduced spectral peaks at the multiples of converter's switching frequency but also exhibits high overall conversion efficiency.

19 November 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Priyabrata ShawPriyabrata Shaw
Priyabrata Shaw
MJManas Kumar Jena
Manas Kumar Jena
Automated event detection and classification are vital to power system monitoring. This paper proposes a novel event detection and classification scheme based on wide area frequency measurement system (WAFMS). Raw frequency measurements obtained from WAFMS are used as the only input to the event detection and classification algorithm (EDCA). Wavelet-based signal pre-processing is used to denoise the data. Afterward, the rate of change of frequency (ROCOF) is estimated from the frequency measurements using the Kalman filter (KF). In the same step, phase angle difference (PAD) across different stations is estimated using WAFMS. Thus, the overall algorithm uses three features such as frequency, ROCOF, and PAD to detect and classify events in the power system. In the first step, an event is detected based on standard deviation (SD) of estimated ROCOF and PAD. In the second step, four types of events are classified using wide area frequency measurements. The suggested algorithms have been validated with real WAFMS data from the Indian Power System, recent 9th August 2019 U.K. blackout data collected from the U.K. power system, and 20th July 2017 oscillation event data obtained from ISO New England (ISO-NE) power system. As a promising tool for power system monitoring, the suggested scheme requires less input measurement for decision making and is having a low computational complexity, which is suitable for practical application.

4 June 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MVMummadi Veerachary
Mummadi Veerachary
Priyabrata ShawPriyabrata Shaw
Priyabrata Shaw
In this paper, a fifth-order boost point-of-load converter is developed by cascading a modified fourth-order boost converter with a combination of L-C and diode. This topology has the following salient features: (i) single-switch topology, (ii) common ground between source and load, (iii) low voltage stress across intermediate capacitors, and (iv) voltage gain same as other reported fifth-order boost converters with no common ground. Steady-state and dynamic analyses demonstrate the proposed converter's boosting feature and dynamic performance respectively. A contoured robust bode plot methodology is employed to design the robust voltage-mode controller to ensure load voltage regulation in the presence of uncertainties. The necessary and sufficient conditions under which the designed controller guarantees the load voltage regulation and robust stability are obtained. A step-by-step robust controller design procedure is outlined. The salient features of proposed converter and its robust performance are studied analytically, using the Matlab platform, and validated experimentally on a 60-Watt prototype module.

18 October 2022 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
Priyabrata ShawPriyabrata Shaw
Priyabrata Shaw
MSMarif Daula Siddique
Marif Daula Siddique
SMSaad Mekhilef
Saad Mekhilef
AIAtif Iqbal
Atif Iqbal

1 December 2015
Verified
Conference Paper
Closed access
PSPradeep Kumar Sahu
Pradeep Kumar Sahu
Priyabrata ShawPriyabrata Shaw
Priyabrata Shaw
SMSomnath Maity
Somnath Maity
This paper presents modeling and control for a single-phase grid-connected two-stage micro-inverter system. An average signal model has been developed for a single-phase bridge inverter. The proposed controller has three cascaded control loops. The inner current loop consists of a variable frequency hysteric current mode control which regulates output filter inductor current thereby improved system response. The small signal modeling of the proposed control method is discussed. Again, as the dc-link capacitor plays a crucial role in two-stage micro inverter applications, a DC-link voltage controller is employed in outer control loop to keep the bus voltage constant. The grid current loop regulates the injected current to the grid at a reduced THD level. The stability of the above control loops are also verified by using Bode-diagram. Finally the proposed method is then applied to 500 Watts, 110V, 50Hz, two- stage single-phase grid-connected Photo-voltaic (PV) system. The simulation and the experimental results are presented to validate the theoretical analysis, effectiveness and feasibility of the proposed control strategy.