T. Renugadevi

Mrs. T. Renugadevi


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
TRT. Renugadevi
T. Renugadevi
KGK Geetha
K Geetha
MKMuthukumar Kandasamy
Muthukumar Kandasamy
ZGZong Woo Geem
Zong Woo Geem
Cloud data center’s total operating cost is conquered by electricity cost and carbon tax incurred due to energy consumption from the grid and its associated carbon emission. In this work, we consider geo-distributed sustainable datacenter’s with varying on-site green energy generation, electricity prices, carbon intensity and carbon tax. The objective function is devised to reduce the operating cost including electricity cost and carbon cost incurred on the power consumption of servers and cooling devices. We propose renewable-aware algorithms to schedule the workload to the data centers with an aim to maximize the green energy usage. Due to the uncertainty and time variant nature of renewable energy availability, an investigation is performed to identify the impact of carbon footprint, carbon tax and electricity cost in data center selection on total operating cost reduction. In addition, on-demand dynamic optimal frequency-based load distribution within the cluster nodes is performed to eliminate hot spots due to high processor utilization. The work suggests optimal virtual machine placement decision to maximize green energy usage with reduced operating cost and carbon emission.

13 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMuthukumar Kandasamy
Muthukumar Kandasamy
TRT. Renugadevi
T. Renugadevi
TAThamaraiselvi Arumugam
Thamaraiselvi Arumugam
JJJ. Jayachandran
J. Jayachandran
WKWookwon Kim
Wookwon Kim
ZGZong Woo Geem
Zong Woo Geem
In this work, an efficient hybrid optimization approach entitled harmony search and particle artificial bee colony algorithm is proposed to deal with the distribution network reconfiguration and solar photovoltaic-based distributed generation and shunt capacitor deployment in power distribution networks to improve the operating performance of power distribution networks. The proposed hybrid algorithm combines the exploration and exploitation capability of both algorithms to achieve optimal results. The optimization problem is formalized which includes distributed generation and shunt capacitor locations, open/close state of switches as discrete decision variables, and the optimum operating point of compensation devices as continuous variables. An efficient spanning tree approach is utilized to track the optimal topology of the network. The validity of the proposed hybrid algorithm in handling the optimal planning problem of the distribution network is assured through eight different operating scenarios at three discrete load levels. The efficiency of the proposed performance enhancement approaches was validated using 69 node and 118 node distribution networks. The obtained results are compared against similar techniques presented in the literature.

14 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TRT. Renugadevi
T. Renugadevi
KGK Geetha
K Geetha
Natarajan PrabaharanNatarajan Prabaharan
Natarajan Prabaharan
PSPierluigi Siano
Pierluigi Siano
The tremendous growth of big data analysis and IoT (Internet of Things) has made cloud computing an integral part of society. The prominent problem associated with data centers is the growing energy consumption, which results in environmental pollution. Data centers can reduce their carbon emissions through efficient management of server power consumption for a given workload. Dynamic voltage frequency scaling (DVFS) can be applied to control the operating frequencies of the servers based on the workloads assigned to them, as this approach has a cubic increment relationship with power consumption. This research work proposes two DVFS-enabled host selection algorithms for virtual machine (VM) placement with a cluster selection strategy, namely the carbon and power-efficient optimal frequency (C-PEF) algorithm and the carbon-aware first-fit optimal frequency (C-FFF) algorithm.The main aims of the proposed algorithms are to balance the load among the servers and dynamically tune the cooling load based on the current workload. The cluster selection strategy is based on static and dynamic power usage effectiveness (PUE) values and the carbon footprint rate (CFR). The cluster selection is also extended to non-DVFS host selection policies, namely the carbon- and power-efficient (C-PE) algorithm, carbon-aware first-fit (C-FF) algorithm, and carbon-aware first-fit least-empty (C-FFLE) algorithm. The results show that C-FFF achieves 2% more power reduction than C-PEF and C-PE, and demonstrates itself as a power-efficient algorithm for CO2 reduction, retaining the same quality of service (QoS) as its counterparts with lower computational overheads.

10 December 2015 in Indian Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
KLKodali Lohita
Kodali Lohita
ASAdusumilli Amitha Sree
Adusumilli Amitha Sree
DPDoreti Poojitha
Doreti Poojitha
TRT. Renugadevi
T. Renugadevi
AUA. Umamakeswari
A. Umamakeswari
Objective: The main objective of the work is to compare the heart disease prediction accuracy of different data mining classification technique and to find the best technique with minimum incorrectly classified instances. Different classification techniques are used to predict heart disease based on the factors that cause these diseases which include family history, age, obesity and some other factors. Method: This work is carried out in three phases. The First Phase is preprocessing of data set. The attributes like trestbps, cholesterol, tpeakbps and age are normalized and missing values are handled appropriately. The second phase is feature selection. The greedy hill climbing best first attribute evaluator is used to identify the subset of attributes based on its individual prediction ability. The third phase is comparison of prediction accuracy of different techniques in literature. Findings: The work has been evaluated using the performance metrics like accuracy, specificity, sensitivity, confusion matrix to prove the efficiency of different techniques. It was concluded that the Bagging algorithm achieved highest accuracy compared with other algorithms.

29 December 2016 in Indian Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
TRT. Renugadevi
T. Renugadevi
RER. Ezhilarasie
R. Ezhilarasie
MSM. Sujatha
M. Sujatha
AUA. Umamakeswari
A. Umamakeswari
Stock Market Prediction using Hierarchical Agglomerative and K-Means Clustering Algorithm

20 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
VNVijithra Nedunchezhian
Vijithra Nedunchezhian
MKMuthukumar Kandasamy
Muthukumar Kandasamy
TRT. Renugadevi
T. Renugadevi
WKWookwon Kim
Wookwon Kim
ZGZong Woo Geem
Zong Woo Geem
The optimal allocation of Photovoltaic (PV) and wind-based renewable energy sources and Battery Energy Storage System (BESS) capacity is an important issue for efficient operation of a microgrid network (MGN). The impact of the unpredictability of PV and wind generation needs to be smoothed out by coherent allocation of BESS unit to meet out the load demand. To address these issues, this article proposes an efficient Energy Management System (EMS) and Demand Side Management (DSM) approaches for the optimal allocation of PV- and wind-based renewable energy sources and BESS capacity in the MGN. The DSM model helps to modify the peak load demand based on PV and wind generation, available BESS storage, and the utility grid. Based on the Real-Time Market Energy Price (RTMEP) of utility power, the charging/discharging pattern of the BESS and power exchange with the utility grid are scheduled adaptively. On this basis, a Jellyfish Search Algorithm (JSA)-based bi-level optimization model is developed that considers the optimal capacity allocation and power scheduling of PV and wind sources and BESS capacity to satisfy the load demand. The top-level planning model solves the optimal allocation of PV and wind sources intending to reduce the total power loss of the MGN. The proposed JSA-based optimization achieved 24.04% of power loss reduction (from 202.69 kW to 153.95 kW) at peak load conditions through optimal PV- and wind-based DG placement and sizing. The bottom level model explicitly focuses to achieve the optimal operational configuration of MGN through optimal power scheduling of PV, wind, BESS, and the utility grid with DSM-based load proportions with an aim to minimize the operating cost. Simulation results on the IEEE 33-node MGN demonstrate that the 20% DSM strategy attains the maximum operational cost savings of €ct 3196.18 (reduction of 2.80%) over 24 h operation, with a 46.75% peak-hour grid dependency reduction. The statistical analysis over 50 independent runs confirms the sturdiness of the JSA over Particle Swarm Optimization (PSO) and Osprey Optimization Algorithm (OOA) with a standard deviation of only 0.00017 in the fitness function, demonstrating its superior convergence characteristics to solve the proposed optimization problem. Finally, based on the simulation outcome of the considered bi-level optimization problem, it can be concluded that implementation of the proposed JSA-based optimization approach efficiently optimizes the PV- and wind-based resource allocation along with BESS capacity and helps to operate the MGN efficiently with reduced power loss and operating costs.