Zhimin Peng

Dr. Zhimin Peng


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
YDYanjun Du
Yanjun Du
ZPZhimin Peng
Zhimin Peng
YDYanjun Ding
Yanjun Ding
A novel method with high accuracy and easy implementation was proposed based on the sinewave-scanned direct absorption spectroscopy (DAS) in this paper. A fitting routine in the time domain was developed to simultaneously deduce the baseline and more importantly, absorbance through the explicit baseline expression offered by the sinewave scan. This method effectively solves the difficulties of baseline determination and provides more accurate wavelength calibration compared with conventional DAS. The accuracy and performance with narrow scans and high frequency were experimentally verified using CO transition at 4300.699 cm−1, from which the inferred line strength agrees well with HITRAN 2016. Meanwhile, a more accurate N2 collisional broadening was provided and the speed-dependent collisional broadening coefficient of this transition was reported for the first time.


26 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZPZhimin Peng
Zhimin Peng
YDYanjun Du
Yanjun Du
YDYanjun Ding
Yanjun Ding
The absorbance is of great importance in the tunable diode laser absorption spectroscopy (TDLAS) as it contains information of both gas properties and spectroscopic parameters. A novel, calibration-free wavelength modulation-direct absorption spectroscopy (WM-DAS) is proposed and experimentally verified in this two-part paper. This method combines the capability of absorbance measurement from DAS and the advantages of enhanced noise rejection and high sensitivity from WMS. In this Part I, we focus on the full theoretical basis and procedures of this method from the following three aspects: the high-accuracy characterizations of laser frequency and intensity, noise rejection ability by extracting the characteristic spectra through the fast Fourier transform (FFT) of the light intensity, and the simultaneous fitting strategy for both baseline and absorbance. The preliminary validation experiment of CO transition at 4300.6999 cm−1 in a static gas cell shows the high accuracy of the proposed method.

1 February 2019 in Journal of Quantitative Spectroscopy and Radiative Transfer
Verified
Journal Article
Closed access
JLJidong Li
Jidong Li
YDYanjun Du
Yanjun Du
ZPZhimin Peng
Zhimin Peng
YDYanjun Ding
Yanjun Ding

22 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZPZhimin Peng
Zhimin Peng
YDYanjun Du
Yanjun Du
YDYanjun Ding
Yanjun Ding
Following the theoretical work in Part I, in this experimental study, the robustness, temporal resolution, and the narrow scan performance of the proposed wavelength modulation-direct absorption spectroscopy (WM-DAS) method are experimentally validated in a high-temperature tube furnace. The electromagnetic and other random-frequency noises can be effectively eliminated by extracting the characteristic spectra of the light intensity. The performance of WM-DAS with modulation frequencies from 0.1 to 100 kHz and scan indexes from 3.3 to 11.1 are also investigated at atmospheric pressure. The proposed method produces accurate line profile and high SNR over 500 consistently even with a weak absorption. As for real applications, the spectral line parameters of CO at 4300.6999 cm−1 including the collisional broadening, Dicke narrowing, and their dependence on temperature are measured. Furthermore, the high-speed measurement (1 ms) of the temperature and CO concentration of a McKenna flat flame are demonstrated.

21 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZhen Wang
Zhen Wang
YDYanjun Du
Yanjun Du
YDYanjun Ding
Yanjun Ding
ZPZhimin Peng
Zhimin Peng
A wide-range, calibration-free tunable diode laser spectrometer is established by combining wavelength modulation and direct absorption spectroscopy (WM-DAS) with continuous wave cavity ringdown spectroscopy (CW-CRDS). This spectrometer combines the benefits of absolute concentration measurements, wide range, and high speed, using WM-DAS with enhanced noise reduction in CW-CRDS. The accurate baseline ringdown time, τ0, is calculated by the absorption peak (measured by WM-DAS) and the ringdown time containing gas absorption information (measured by CW-CRDS at the center wavelength of the spectral line). The gas concentration is obtained without measuring τ0 in real time, thus, greatly improving the measuring speed. A WM-DAS/CW-CRDS spectrometer at 1.57 μm for CO detection was assembled for experimental validation of the multiplexing scheme over a concentration ranging from 4 ppm to 1.09% (0.1 MPa, 298 K). The measured concentration of CO at 6374.406 cm−1 shows that the dynamic range of this tunable diode laser absorption spectrometer is extendable up to five orders of magnitude and the corresponding precision is improved. The measurement speed of this spectrometer can extend up to 10 ms, and the detection limit can reach 35 ppb within 25 s.