In order to improve the sensitivity of liquid dielectric constant measurements, a liquid dielectric constant sensor based on a cubic container structure is proposed for the first time. The cubic container, which consists of a dielectric substrate with a split resonant ring (SRR) and microstrip lines, can enhance the electric field intensity in the measuring area. High sensitivity can be obtained from measuring the dielectric constant with the characteristics of the structure resonate. The research results show that the resonant frequency of the sensor is shifted from 7.69 GHz to 5.70 GHz, with about a 2 GHz frequency offset, when the dielectric constant of the sample varied from 1 to 10. A resonance frequency offset of 200 MHz for the per unit dielectric constant is achieved, which is excellent regarding performance. The permittivity of oil with a different metal content is measured by using the relation between the fitted permittivity and the resonant frequency. The relative error is less than 1.5% and the sensitivity of measuring is up to 3.45%.
In this Letter, we propose an approach to generate high-purity orbital angular momentum (OAM) vortex waves using an amplitude-and-phase metasurface (APM). By varying the square split ring opening and orientation angles, the cross-polarized reflection response of the proposed structure can yield full phase and amplitude coverage. Based on the traditional phase-only metasurface (POM), the Chebyshev synthesis method (CSM) is applied to array the metasurface amplitude distribution. Metasurfaces with modes of 1, 2, 3, and 4 are designed. Compared with the POM, the APM can effectively improve the vortex beam quality and OAM mode purity. The measured results agree well with full-wave simulations. The presented method provides a new, to the best of our knowledge, way to design high-purity OAM generators based on metasurfaces.
In order to solve the low-sensitivity problem of the dielectric constant with the resonant cavity method, a sensor based on a substrate-integrated waveguide structure loaded with a multi-complementary open resonant ring is proposed. With the enhanced resonance characteristics of the sensor, this design realized the measurement of complex dielectric constants in a wide range. The frequency selectivity of the sensor is improved by the high-quality factor of the substrate-integrated waveguide. By loading three complementary resonant rings with different opening directions in the ground plane, a deeper notch and better out-of-band suppression are achieved. The effect of the complex dielectric constant on both resonant frequency and quality factor is discussed by calculating the material under test with a known dielectric constant. Simulation and experimental results show that a resonance frequency offset of 102 MHz for the per unit dielectric constant is achieved. A wide frequency offset is the prerequisite for accurate measurement. The measurement results of four plates match well with the standard values, with a relative error of the real part of the dielectric constant of less than 2% and an error of less than 0.0099 for the imaginary part.
A broadband dual-polarized base station antenna is proposed in this paper. The antenna consists of loop cross-dipoles, Y-shaped coupling feeding lines, and a metal box reflector. An equivalent circuit model including a signal flow diagram is established to analyze the mechanism of the proposed antenna in detail. Moreover, the Y-shaped coupling feeding lines are introduced to control the coupling with the antenna to achieve broadband and good impedance matching. The prototype of the antenna is fabricated and measured. The measured results show that the antenna with simple structures can operate at the band of 3.2–5.22 GHz (48%) with high port-to-port isolation (35 dB) and stable gain (9 ± 1 dBi). The measured results show good agreement with simulated results, especially in cross-polarization discrimination ratio (>27 dB) and the half power beam width (61° ± 3° at the E-plane, 68° ± 3° at the H-plane). In summary, the proposed antenna could be a good candidate for 5G sub-6 GHz base station applications.
Absorption loss in optical components, particularly in optical coatings, is a limiting factor in high-power laser applications. The uniformity of optical coatings becomes more and more important as large-diameter optical devices are used widely. In this paper, the photothermal detuning technique used for absorption uniformity measurement of optical thin films is developed for the first time. Experiments are conducted with a highly reflective coating used in 514 nm to measure the photothermal detuning signal and to evaluate the absorption at 514 nm by detecting the spectral shift with a probe beam at a wavelength of 632.8 nm. The relative absorption at different points on the sample surface can be measured by moving the sample two-dimensionally, and we use the measured data to make the absorption image. The results show that the designed experimental system can be used to analyze the absorption uniformity of optical coatings. The obtained images reflect the absorption uniformity of the sample well. The absorption uniformities of the two samples analyzed in this experiment are different. The film coated on fused silica is better. The research provides a powerful and convenient tool for absorption uniformity measurement of optical thin film.