Rusi Taleyarkhan

Prof. Dr. Rusi Taleyarkhan

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2004 in Physical Review E
Verified
Journal Article
Closed access
PDF file
RTRusi Taleyarkhan
Rusi Taleyarkhan
Jung Sang ChoJung Sang Cho
Jung Sang Cho
CWC. D. West
C. D. West
RLR. T. Lahey
R. T. Lahey
RNR. I. Nigmatulin
R. I. Nigmatulin
RBR. C. Block
R. C. Block
Time spectra of neutron and sonoluminescence emissions were measured in cavitation experiments with chilled deuterated acetone. Statistically significant neutron and gamma ray emissions were measured with a calibrated liquid-scintillation detector, and sonoluminescence emissions were measured with a photomultiplier tube. The neutron and sonoluminescence emissions were found to be time correlated over the time of significant bubble cluster dynamics. The neutron emission energy was less than 2.5 MeV and the neutron emission rate was up to ∼4×105 n/s. Measurements of tritium production were also performed and these data implied a neutron emission rate due to D-D fusion which agreed with what was measured. In contrast, control experiments using normal acetone did not result in statistically significant tritium activity, or neutron or gamma ray emissions.

27 January 2006 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
RTRusi Taleyarkhan
Rusi Taleyarkhan
CWC. D. West
C. D. West
RLR. T. Lahey
R. T. Lahey
RNR. I. Nigmatulin
R. I. Nigmatulin
RBR. C. Block
R. C. Block
YXY. Xu
Y. Xu
A unique, new stand-alone acoustic inertial confinement nuclear fusion test device was successfully tested. Experiments using four different liquid types were conducted in which bubbles were self-nucleated without the use of external neutrons. Four independent detection systems were used (i.e., a neutron track plastic detector to provide unambiguous visible records for fast neutrons, a BF3 detector, a NE-113-type liquid scintillation detector, and a NaI γ ray detector). Statistically significant nuclear emissions were observed for deuterated benzene and acetone mixtures but not for heavy water. The measured neutron energy was ≤2.45  MeV, which is indicative of deuterium-deuterium (D-D) fusion. Neutron emission rates were in the range ∼5×103  n/s to ∼104  n/s and followed the inverse law dependence with distance. Control experiments did not result in statistically significant neutron or γ ray emissions.

5 March 2008 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
RTRusi Taleyarkhan
Rusi Taleyarkhan
JLJ. Lapinskas
J. Lapinskas
YXY. Xu
Y. Xu

1 August 2004 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
RNR. I. Nigmatulin
R. I. Nigmatulin
RTRusi Taleyarkhan
Rusi Taleyarkhan
RLR. T. Lahey
R. T. Lahey
This paper extends the experimental and numerical results presented previously and addresses the major criticisms raised. In addition, the most recent results are discussed. In acoustic cavitation experiments with chilled (ɛ0 °C) deuterated acetone (C3D6O), the production of tritium and 2.45 MeV neutrons [which are characteristic of deuterium-deuterium (D-D) fusion] was observed during vapour bubble implosions in an acoustic pressure field. Similar experiments with deuterated acetone at room temperature (ɛ20 °C) and control experiments with normal acetone (C3H6O), at both 0 and 20 °C, showed no statistically significant increases in either tritium level or neutron emissions. Numerical simulations of the processes that account for the shock waves generated in the liquid and within the collapsing bubbles supported these experimental observations and showed that high densities and temperatures (° 108 K) may be achieved during bubble cloud implosions, yielding the conditions required for D-D nuclear fusion reactions. The present paper treats the bubble fusion experiments and theoretical results in greater detail than was possible in the previous publications, contains some refinements, addresses some important questions raised by reviewers and critics and discusses possible applications of this interesting phenomenon.

31 May 2005 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
RTRusi Taleyarkhan
Rusi Taleyarkhan

23 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RTRusi Taleyarkhan
Rusi Taleyarkhan
The monitoring of neutron radiation in extreme high ≈1014 (#/cm2-s) neutron/photon fields and at extremely-low (≈10−3 #/cm2-s) levels poses daunting challenges—important in fields spanning nuclear energy, special nuclear material processing/security, nuclear medicine (e.g., photon-based cancer therapy), and high energy (e.g., dark-matter) research. Variably proportioned (neutron, gammas, X-ray) radiation, spanning 10−2–109 eV in energy, is omnipresent from ultra-low (Bq) activity levels (e.g., cosmic rays/ bananas), to extreme high (>1020 Bq) levels. E.g., in nuclear reactor cores; in spent nuclear fuel bearing nuclear-explosive-relevant safeguard-sensitive isotopes, such as Pu-239; and in cancer therapy accelerators. The corresponding high to low radiation dose range spans a daunting 1016:1 spread—alongside ancillary challenges such as high temperatures, pressure, and humidity. Commonly used neutron sensors get readily saturated even in modest (<1 R/h) photon fields; importantly, they are unable to decipher trace neutron radiation relative to 1014 times greater gamma radiation. This paper focuses on sensing ultra-low to high neutron radiation in extremely high photon (gamma-X ray) backgrounds. It summarizes the state-of-art compared to the novel tensioned metastable fluid detector (TMFD) sensor technology, which offers physics-based 100% gamma-blind, high (60–95%) intrinsic efficiency for neutron-alpha-fission detection, even under extreme (≈103 R/h) gamma radiation.