The Gordon-Ng models are tools that have been used to estimate and evaluate the performance of various types of chillers for several years. A 550 TR centrifugal chiller plant facility was available to collect data from July and September 2018. The authors propose rearranging variables of the traditional (GNU) model based on average electric consumption and through a thermodynamic analysis comparable to the original model. Furthermore, assumptions are validated. Then, by estimation of the parameters of the new model using least square fitting with field training data and comparing to the GNU model and Braun model (based on consumption), it was shown that the proposed model provides a better prediction in order to evaluate consumption of a centrifugal chiller in regular operation, by improving the coefficient of variation (CV), CV = 3.24% and R2 = 92.52% for a filtered sub-data. Through an algorithm built from steady-state cycle analysis, physical parameters (Sgen, Qleak,eq, R) were estimated to compare with the same parameters obtained by regression to check the influence of the interception term in the model. It was found that without an interception term, the estimated parameters achieve relative errors (ER) below 20%. Additional comparison between external and internal power prediction is shown, with CV = 3.57 % and mean relative error (MRE) of 2.7%, achieving better accuracy than GNU and Braun model.
29 October 2020 in Revista Facultad de Ingeniería Universidad de Antioquia
In this study, a novel experimental approach for the optimal selection of an actuator-based control strategy is presented. The proposed approach is a two-stage method: first, a two-level factorial experiment design with n factors (2n) was applied to compare different control schemes. Schemes comparison was carried out in terms of energy consumption and closed-loop performance. For the best relative scheme, a Central Composite Face-centered (CCF) design was completed obtaining the controller parameters that optimize the performance in terms of the Integral Absolute Error (IAE) while operating in a region of low energy consumption. The proposed approach was experimentally tested using real data obtained from a laboratory prototype plant. Some experimental tests illustrating the suitability of our method are shown at the end of this article.
The global transition to electric vehicles is essential for reducing transportation-related carbon emissions. Despite this, the limited driving range, primarily caused by the high energy consumption of thermal management systems, remains a significant barrier to the widespread adoption of EVs. Concurrently, international regulations are phasing out conventional refrigerants with high global warming potential, leading to the use of natural refrigerants, such as carbon dioxide (R744). R744 meets environmental standards and exhibits favorable thermodynamic performance. The current state of R744-based thermal management in EVs advancements in transcritical R744 heat pumps technologies, operational challenges and optimization strategies were comprehensively reviewed in this work. The review also included an overview of the present landscape and prospects for R744-based TMS in next-generation electric vehicles. It could be concluded that future thermal management strategies of EVs can be based on integrated R744-based solutions, featuring further advanced add-ons, such as AI-based control strategies.