The paper is concerned with water vapor condensation on vertical pipes. The vertical position of pipes in a condenser is not discussed very often. Its application has a number of particularities in terms of the numerical determination of heat transfer. In the first stage of this paper, the authors focus on the experimental identification of heat transfer during vapor condensation on vertical pipes with a diameter of 14.0 × 1.0 mm. The pipes are placed in a narrow channel and the steam flows around them in a perpendicular direction. Two channel widths were tested, i.e., 20.0 and 24.0 mm. In the second stage, numerical modelling (CFD) is used for a detailed identification of the vapor velocity fields near the pipes. In the third stage, the results of the experimental measurements and numerical modelling are compared with data published by various authors. There are studies in the literature dealing with axial flow around vertical pipes; however, the associated results are based on conditions which are distinct from those applied in our study. The outcome of this paper is the specification of the heat transfer coefficient and the calculation formulas precisely describing the studied condenser configuration.
This paper presents the design and test results of an external thermoelectric generator that utilizes the waste heat from a small-scale domestic biomass boiler with nominal rated heat output of 25 kW. The low-temperature Bi2Te3 generator based on thermoelectric modules has the potential to recover waste heat from gas combustion products as effective energy. The small-scale generator is constructed from independent segments. Measurements have shown that up to 11 W of electricity can be generated by one segment. Higher output power can be achieved by linking thermoelectric segments. The maximum output power is given by the dew point of the flue gas. The electrical energy that is generated can be used, e.g., for power supply or for charging batteries. In the near future, thermoelectric generators could completely eliminate the dependence an automated domestic boiler system on the power supply from the electricity grid, and could ensure comfortable operation in the event of an unexpected power grid failure.