Se Woo Park

Prof. Se Woo Park

Hallym University College of Medicine
orcid

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
CPChan Hyuk Park
Chan Hyuk Park
JJJang Han Jung
Jang Han Jung
ENEunwoo Nam
Eunwoo Nam
EKEun Hye Kim
Eun Hye Kim
MKMi Gang Kim
Mi Gang Kim
SPSe Woo Park
Se Woo Park

3 November 2015 in Digestive Diseases and Sciences
Verified
Journal Article
Closed access
PDF file
SPSe Woo Park
Se Woo Park
Hyuk LeeHyuk Lee
Hyuk Lee
HAHongyup Ahn
Hongyup Ahn

1 September 2017 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
MKMi Gang Kim
Mi Gang Kim
SPSe Woo Park
Se Woo Park
JKJae Hyun Kim
Jae Hyun Kim
JLJin Lee
Jin Lee
SKSea Hyub Kae
Sea Hyub Kae
MCMin Ho Choi
Min Ho Choi

1 August 2015 in Journal of Gastrointestinal Surgery
Verified
Journal Article
Open access
PDF file
SPSe Woo Park
Se Woo Park
HLHang Lak Lee
Hang Lak Lee
EDEun Young Doo
Eun Young Doo
KLKang Nyeong Lee
Kang Nyeong Lee
DJDae Won Jun
Dae Won Jun
KLKang Hong Lee
Kang Hong Lee
Background The relationship between visceral obesity and colon cancer outcome has not been well studied. The goal of this study was to determine the impact of visceral obesity on lymph node (LN) metastasis and overall survival (OS) in colon cancer. Materials and Methods Metastatic LN ratio (MLR) was defined as the number of involved nodes by tumor divided by the total number of resected LNs. Visceral (VFA) and subcutaneous fat areas (SFA) were determined by measuring abdominal fat volume distribution via CT scan, and visceral obesity was defined as a VFA to total fat area ratio (V/T) > 0.29. Results In a multivariate analysis among 186 patients, there were inverse associations between V/T and MLR (OR = 0.413, 95 % CI = 0.216–0.789, P = 0.007). Furthermore, patients with visceral obesity tended to have significantly better OS than patients with non-visceral obesity. Conclusions Higher V/T ratios which indicate referring to visceral obesity was significantly associated with decreased MLR and better OS for CRC.

6 July 2021 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
CPChan Hyuk Park
Chan Hyuk Park
SPSe Woo Park
Se Woo Park
MYMin Jae Yang
Min Jae Yang
SMSung Hoon Moon
Sung Hoon Moon
DPDa Hae Park
Da Hae Park

5 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MCMoon Jae Chung
Moon Jae Chung
SLSang Hoon Lee
Sang Hoon Lee
HLHee Seung Lee
Hee Seung Lee
HLHyun Jik Lee
Hyun Jik Lee
JPJeong Youp Park
Jeong Youp Park
SBSeungmin Bang
Seungmin Bang
Although thicker needles theoretically allow more tissue to be collected, their decreased flexibility can cause mechanical damage to the endoscope, technical failure, and sample blood contamination. The effects of needle gauge on diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of pancreatic mass lesions remain unknown. This study compared procurement rates of histologic cores obtained from EUS-FNB of pancreatic masses using 25- and 22-gauge core biopsy needles. From March 2014 to July 2014, 66 patients with solid pancreatic mass underwent EUS-FNB with both 25- and 22-gauge core biopsy needles. Among them, 10 patients were excluded and thus 56 patients were eligible for the analyses. Needle sequences were randomly assigned, and two passes were made with each needle, consisting of 10 uniform to-and-fro movements on each pass with 10 mL syringe suction. A pathologist blinded to needle sequence evaluated specimens for the presence of histologic core. The mean patient age was 65.8 ± 9.5 years (range, 44–89 years); 35 patients (62.5%) were men. The mean pancreatic mass size was 35.3 ± 17.1 mm (range 14–122.3 mm). Twenty-eight patients (50%) had tumors at the pancreas head or uncinate process. There were no significant differences in procurement rates of histologic cores between 25-gauge (49/56, 87.5%) and 22-gauge (46/56, 82.1%, P = 0.581) needles or diagnostic accuracy using only histologic cores (98% and 95%). There were no technical failures or procedure-related adverse events. The 25-gauge core biopsy needle could offer acceptable and comparable outcomes regarding diagnostic performance including histologic core procurement rates compared to the 22-gauge core biopsy needle, although the differences were not statistically significant. ClinicalTrials.gov NCT01795066