Isabel M. Gomez-Gonzalez

Prof. Dr. Isabel M. Gomez-Gonzalez

University of Seville, Seville, Spain
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2010
Verified
Conference Paper
Open access
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
Octavio RiveraOctavio Rivera
Octavio Rivera
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
EDEnrique Dorronzoro
Enrique Dorronzoro
In this paper, a signal processing algorithm to detect eye movements is developed. The algorithm works with two kinds of inputs: derivative and amplitude level of electrooculographic signal. Derivative is used to detect signal edges and the amplitude level is used to filter noise. Depending of movement direction, different kinds of events are generated. Events are associated with a movement and its route. A hit rate equal to 94% is reached. This algorithm has been used to implement an application that allows computer control using ocular movement.

6 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlmudena Serrano-Barroso
Almudena Serrano-Barroso
RSRoma Siugzdaite
Roma Siugzdaite
JGJaime Guerrero-Cubero
Jaime Guerrero-Cubero
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
JVJuan Pedro Vargas
Juan Pedro Vargas
Attentional biomarkers in attention deficit hyperactivity disorder are difficult to detect using only behavioural testing. We explored whether attention measured by a low-cost EEG system might be helpful to detect a possible disorder at its earliest stages. The GokEvolution application was designed to train attention and to provide a measure to identify attentional problems in children early on. Attention changes registered with NeuroSky MindWave in combination with the CARAS-R psychological test were used to characterise the attentional profiles of 52 non-ADHD and 23 ADHD children aged 7 to 12 years old. The analyses revealed that the GokEvolution was valuable in measuring attention through its use of EEG–BCI technology. The ADHD group showed lower levels of attention and more variability in brain attentional responses when compared to the control group. The application was able to map the low attention profiles of the ADHD group when compared to the control group and could distinguish between participants who completed the task and those who did not. Therefore, this system could potentially be used in clinical settings as a screening tool for early detection of attentional traits in order to prevent their development.

23 April 2015 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper describes an offline version and a real-time implementation of a new algorithm to determine QRS localization in the ECG signal based on its envelopment and K-means clustering algorithm. The envelopment is used to obtain a signal with only QRS complexes, deleting P, T, and U waves and baseline wander. Two moving average filters are applied to smooth data. The K-means algorithm classifies data into QRS and non-QRS. The technique is validated using 22 h of ECG data from five Physionet databases. These databases were arbitrarily selected to analyze different morphologies of QRS complexes: three stored data with cardiac pathologies, and two had data with normal heartbeats. The algorithm has a low computational load, with no decision thresholds. Furthermore, it does not require any additional parameter. Sensitivity, positive prediction and accuracy from results are over 99.7%.

4 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
Sergio LafuenteSergio Lafuente
Sergio Lafuente
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
Detecting stress when performing physical activities is an interesting field that has received relatively little research interest to date. In this paper, we took a first step towards redressing this, through a comprehensive review and the design of a low-cost body area network (BAN) made of a set of wearables that allow physiological signals and human movements to be captured simultaneously. We used four different wearables: OpenBCI and three other open-hardware custom-made designs that communicate via bluetooth low energy (BLE) to an external computer—following the edge-computingconcept—hosting applications for data synchronization and storage. We obtained a large number of physiological signals (electroencephalography (EEG), electrocardiography (ECG), breathing rate (BR), electrodermal activity (EDA), and skin temperature (ST)) with which we analyzed internal states in general, but with a focus on stress. The findings show the reliability and feasibility of the proposed body area network (BAN) according to battery lifetime (greater than 15 h), packet loss rate (0% for our custom-made designs), and signal quality (signal-noise ratio (SNR) of 9.8 dB for the ECG circuit, and 61.6 dB for the EDA). Moreover, we conducted a preliminary experiment to gauge the main ECG features for stress detection during rest.

6 March 2023 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Open access
PDF file
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
CLClara Lebrato-Vázquez
Clara Lebrato-Vázquez
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
The analysis of cardiac activity is one of the most common elements for evaluating the state of a subject, either to control possible health risks, sports performance, stress levels, etc. This activity can be recorded using different techniques, with electrocardiogram and photoplethysmogram being the most common. Both techniques make significantly different waveforms, however the first derivative of the photoplethysmographic data produces a signal structurally similar to the electrocardiogram, so any technique focusing on detecting QRS complexes, and thus heartbeats in electrocardiogram, is potentially applicable to photoplethysmogram. In this paper, we develop a technique based on the wavelet transform and envelopes to detect heartbeats in both electrocardiogram and photoplethysmogram. The wavelet transform is used to enhance QRS complexes with respect to other signal elements, while the envelopes are used as an adaptive threshold to determine their temporal location. We compared our approach with three other techniques using electrocardiogram signals from the Physionet database and photoplethysmographic signals from the DEAP database. Our proposal showed better performances when compared to others. When the electrocardiographic signal was considered, the method had an accuracy greater than 99.94%, a true positive rate of 99.96%, and positive prediction value of 99.76%. When photoplethysmographic signals were investigated, an accuracy greater than 99.27%, a true positive rate of 99.98% and positive prediction value of 99.50% were obtained. These results indicate that our proposal can be adapted better to the recording technology.

8 August 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
Manuel Merino-MongeManuel Merino-Monge
Manuel Merino-Monge
IGIsabel M. Gomez-Gonzalez
Isabel M. Gomez-Gonzalez
In this article we present a new low-cost physiological signal acquisition platform in compliance with OSHW philosophy. The device contains an ECG circuit; two EDA channels that implement a time-multiplexing technique to remove inter-channel coupling interference; and a skin temperature module. These features make the platform suitable for experiments involving AC. We have assessed the performance of this device in terms of SNR and BNL, an adapted MPEG7 feature for ECG signals. This platform outperforms other commercial devices and most similar state-of-art studies on SNR. Results show values of 11.96, 30.01, 68.40 dB for ECG, EDA and T respectively for SNR, and -28.31 dB for BNL in ECG. Both features were obtained by sampling physiological signals at a frequency of 256 Hz.