Methods to detect outliers in network flow measurements that may be due to pipe bursts or unusual consumptions are fundamental to improve water distribution system on-line operation and management, and to ensure reliable historical data for sustainable planning and design of these systems. To detect and classify anomalous events in flow data from district metering areas a four-step methodology was adopted, implemented and tested: i) data acquisition, ii) data validation and normalization, iii) anomalous observation detection, iv) anomalous event detection and characterization. This approach is based on the renewed concept of outlier regions and depends on a reduced number of configuration parameters: the number of past observations, the true positive rate and the false positive rate. Results indicate that this approach is flexible and applicable to the detection of different types of events (e.g., pipe burst, unusual consumption) and to different flow time series (e.g., instantaneous, minimum night flow).
This paper presents a novel energy balance scheme and performance indicators for assessing energy efficiency in water supply systems. This assessment consists of a three-step procedure: system characterisation and data collection, energy balance calculation and energy performance indicators assessment. The main innovation is the integrated approach between energy and water balances allowing the quantification of energy inefficiencies directly associated with water losses. Comprehensive energy performance indicators can be calculated by utilities with different maturity levels allowing a fair comparison of energy efficiency between systems with different layouts and operational schemes. This energy balance scheme has been applied by 17 water utilities in Portugal. Results have shown that systems provide more than twice the minimum energy necessary to supply their consumers and, consequently, there is a significant energy saving potential: 40% through water loss reduction, 30% for changes in network operation and layout and 30% for pump inefficiency reduction.
The current study focuses on the analysis of pressure surge damping in single pipeline systems generated by a fast change of flow conditions. A dimensionless form of pressurised transient flow equations was developed, presenting the main advantage of being independent of the system characteristics. In lack of flow velocity profiles, the unsteady friction in turbulent regimes is analysed based on two new empirical corrective- coefficients associated with local and convective acceleration terms. A new surge damping approach is also presented taking into account the pressure peak time variation. The observed attenuation effect in the pressure wave for high deformable pipe materials can be described by a combination of the non-elastic behaviour of the pipe-wall with steady and unsteady friction effects. Several simulations and experimental tests have been carried out, in order to analyse the dynamic response of single pipelines with different characteristics, such as pipe materials, diameters, thickness, lengths and transient conditions.
1 November 2004 in Journal of Water Supply: Research and Technology—AQUA
Degradation of water quality in supply and distribution systems is one of the foremost problems that water companies are faced with. It is everyday practice in many countries to maintain a residual quantity of a disinfectant such as chlorine throughout the system, in order to ensure the safety of distributed water. However, the chlorine added at the water treatment plant disappears as it travels to the consumer tap, due to reactions in the bulk of the flow and at the pipe walls. This paper analyses the influence on free chlorine bulk decay of several water quality parameters, such as temperature, initial chlorine dosage, organic matter and iron content. The performance of five alternative kinetic models for describing the disinfectant behaviour is also assessed, considering both static and steady-state flow conditions. For the conditions tested, a parallel pseudo-first order model provided the best results. Although, in practice, parallel first order kinetic models fit experimental data better than the classic first order model, most water quality modelling software still relies on the latter as a base choice. The paper discusses practical conditions that may influence model selection for network simulation purposes, and the relevance of the associated errors.
Water losses are responsible for increased energy consumption in water supply systems (WSS). The energy associated with water losses (EWL) is typically considered to be proportional to the water loss percentage obtained in water balances. However, this hypothesis is yet to be proved since flow does not vary linearly with headlosses in WSS. The aim of this paper is to validate the hypothesis, present real-life values for water-energy balance (WEB) components, and reference values for the key performance indicator that represents the ratio of total energy in excess (E3). This validation is achieved through the application of two approaches—top-down and bottom-up. The first approach requires minimum data, gives an overview of the main WEB components, and provides an effective diagnosis of energy inefficiencies through the calculation of E3 related to pumps, water losses, and networks. The second approach requires calibrated hydraulic models and provides a detailed assessment of the WEB components. Results allow the validation of the stated hypothesis as well as show that the most significant energy inefficiencies are associated with surplus energy, pumping, and water losses, each reaching up to 40% of total input energy. Less significant components are pipe friction and valve headlosses, each reaching up to 15% of total input energy.