Christoph Gregor Trumm

Prof. Dr. Christoph Gregor Trumm

Institute of Neuroradiology, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 May 2014 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
SHSophia M. Häußler
Sophia M. Häußler
AMAlexander Muacevic
Alexander Muacevic
RSRobert Stahl
Robert Stahl
SSSebastian Stintzing
Sebastian Stintzing
RHRalf-Thorsten Hoffmann
Ralf-Thorsten Hoffmann

1 June 2013 in Investigative Radiology
Verified
Journal Article
Closed access
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
RSRobert Stahl
Robert Stahl
DCDirk Clevert
Dirk Clevert
PHPeter Herzog
Peter Herzog
IMIrene Mindjuk
Irene Mindjuk
MMMatthias Matzko
Matthias Matzko
Objectives The aim of this study was to assess the impact of the advanced technology of the new ExAblate 2100 system (Insightec Ltd, Haifa, Israel) for magnetic resonance imaging (MRI)–guided focused ultrasound surgery on treatment outcomes in patients with symptomatic uterine fibroids, as measured by the nonperfused volume ratio. Materials and Methods This is a retrospective analysis of 115 women (mean age, 42 years; range, 27–54 years) with symptomatic fibroids who consecutively underwent MRI-guided focused ultrasound treatment in a single center with the new generation ExAblate 2100 system from November 2010 to June 2011. Mean ± SD total volume and number of treated fibroids (per patient) were 89 ± 94 cm3 and 2.2 ± 1.7, respectively. Patient baseline characteristics were analyzed regarding their impact on the resulting nonperfused volume ratio. Results Magnetic resonance imaging–guided focused ultrasound treatment was technically successful in 115 of 123 patients (93.5%). In 8 patients, treatment was not possible because of bowel loops in the beam pathway that could not be mitigated (n = 6), patient movement (n = 1), and system malfunction (n = 1). Mean nonperfused volume ratio was 88% ± 15% (range, 38%-100%). Mean applied energy level was 5400 ± 1200 J, and mean number of sonications was 74 ± 27. No major complications occurred. Two cases of first-degree skin burn resolved within 1 week after the intervention. Of the baseline characteristics analyzed, only the planned treatment volume had a statistically significant impact on nonperfused volume ratio. Conclusions With technological advancement, the outcome of MRI-guided focused ultrasound treatment in terms of the nonperfused volume ratio can be enhanced with a high safety profile, markedly exceeding results reported in previous clinical trials.


28 January 2012 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
APAnne Pahl
Anne Pahl
THThomas K. Helmberger
Thomas K. Helmberger
TJTobias Jakobs
Tobias Jakobs
CZChristoph J. Zech
Christoph J. Zech
RHRalf-Thorsten Hoffmann
Ralf-Thorsten Hoffmann

4 September 2008 in Der Radiologe
Verified
Journal Article
Closed access
PDF file
TJTatjana C Jakobs
Tatjana C Jakobs
RHR.T. Hoffmann
R.T. Hoffmann
KTK. Tatsch
K. Tatsch
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
MRM.F. Reiser
M.F. Reiser