The paper presents a concept where pairs of ordinary RFID tags are exploited for use as remotely read moisture sensors. The pair of tags is incorporated into one label where one of the tags is embedded in a moisture absorbent material and the other is left open. In a humid environment the moisture concentration is higher in the absorbent material than the surrounding environment which causes degradation to the embedded tag's antenna in terms of dielectric losses and change of input impedance. The level of relative humidity or the amount of water in the absorbent material is determined for a passive RFID system by comparing the difference in RFID reader output power required to power up respectively the open and embedded tag. It is similarly shown how the backscattered signal strength of a semi-active RFID system is proportional to the relative humidity and amount of water in the absorbent material. Typical applications include moisture detection in buildings, especially from leaking water pipe connections hidden beyond walls. Presented solution has a cost comparable to ordinary RFID tags, and the passive system also has infinite life time since no internal power supply is needed. The concept is characterized for two commercial RFID systems, one passive operating at 868 MHz and one semi-active operating at 2.45 GHz.
19 June 2014 in IEEE Transactions on Instrumentation and Measurement
In this paper, a time-domain system dedicated to medical diagnostics has been designed, a prototype has been built and its performance has been evaluated. Measurements show that the system has a 3-dB bandwith of about 3.5 GHz and a signal to noise ratio over 40 dB in the frequency range about 800 MHz to 3.8 GHz. The system has been used to perform a microwave tomographic image reconstruction test. The same target was reconstructed based on data measured with a network analyzer. A comparison between the images shows very small differences, and proves the functionality of the time domain system.
12 August 2011 in IEEE Transactions on Antennas and Propagation
We perform a theoretical analysis of the measurement accuracy of ultrawideband time domain systems. The theory is tested on a specific ultrawideband system and the analytical estimates of measurement uncertainty are in good agreements with those obtained by means of simulations. The influence of the antennas and propagation effects on the measurement accuracy of time domain near field microwave imaging systems is discussed. As an interesting application, the required measurement accuracy for a breast cancer detection system is estimated by studying the effect of noise on the image reconstructions. The results suggest that the effects of measurement errors on the reconstructed images are small when the amplitude uncertainty and phase uncertainty of measured data are less than 1.5 dB and 15 degrees, respectively.
5 May 2011 in IEEE Transactions on Instrumentation and Measurement
The measurement accuracy of an ultrawideband (UWB) time-domain microwave-tomographic system is investigated. In order to make an assessment of the random variation of the measurements, the measurement repeatability of the system is evaluated by comparison with an UWB frequency-domain system. A phantom is imaged with the time-domain microwave-tomographic system, and the reconstructed images are compared with those obtained by using the frequency-domain system. The results suggest that with the averaging tens of measurements, the time-domain system can achieve the same level of measurement repeatability as that of the frequency-domain system in the interesting frequency range of microwave tomography. The imaging results, however, indicate that the phantom reconstruction does not require such high measurement accuracy. The permittivity profile of the phantom reconstructed from the nonaveraging time-domain measurements is very similar with that obtained by means of the frequency-domain system.
1 January 2017 in Progress In Electromagnetics Research B
In hyperthermia treatment planning (HTP) the goal is to find the amplitudes and phases of antennas in the applicator to efficiently heat the tumor. To do this prior information regarding tumor characteristics such as the size, position and geometry, in addition to an exact model of the hyperthermia applicator is needed. Based on this information, the optimal frequency of operation can be determined. In this paper the optimum frequency for hyperthermia treatment based on the tumor and applicator characteristics, using time reversal as the focusing technique, is studied. As prior information, we consider tumor size and position, the number of the antennas in the applicator and the frequency characteristics. The obtained optimal frequency range is found using hyperthermia quality indicator values calculated from simulations. We also determine the optimum position of the virtual source in the initial step of the time reversal method to increase the quality of the treatment.
We studied the use of a millimeter-wave frequency-modulated continuous wave radar for gait analysis in a real-life environment, with a focus on the measurement of the step time. A method was developed for the successful extraction of gait patterns for different test cases. The quantitative investigation carried out in a lab corridor showed the excellent reliability of the proposed method for the step time measurement, with an average accuracy of 96%. In addition, a comparison test between the millimeter-wave radar and a continuous-wave radar working at 2.45 GHz was performed, and the results suggest that the millimeter-wave radar is more capable of capturing instantaneous gait features, which enables the timely detection of small gait changes appearing at the early stage of cognitive disorders.