Gintautas Skripkiunas

Prof. Dr. Gintautas Skripkiunas

Department of Building Materials and Fire Safety, Faculty of Civil Engineering, Vilnius Gediminas Technical University, LT-10223 Vilnius, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Procedia Engineering
Verified
Journal Article
Open access
Gintautas SkripkiunasGintautas Skripkiunas
Gintautas Skripkiunas
DNDžigita Nagrockienė
Džigita Nagrockienė
GGGiedrius Girskas
Giedrius Girskas
MVMarija Vaičienė
Marija Vaičienė
EBErika Baranauskaitė
Erika Baranauskaitė
This paper analyzes the effect of the four types of cement (Portland cement, blast-furnace Portland cement, limestone Portland cement and blast-furnace cement) on freeze-thaw and deicing salt resistance of concrete. Eight compositions of concrete with different cements were tested. Four compositions contained hydration retarder added at 0.3 wt% and 0.5 wt% by mass of cement and four compositions were without the retarder. All compositions contained 0.6 wt% of superplasticizer. 3% NaCl solutions was used as a freezing agent in freeze-thaw tests. The mass loss (the weight of scaled material), ultrasonic pulse velocity and residual deformations were measured every seven freeze-thaw cycle. The test results showed that the highest freeze-thaw and deicing salt resistance is observed in concrete made of blast-furnace cement (CEM III/B 32.5N - LH) and the lowest freeze-thaw resistance is observed in concrete made of Portland cement (CEM I 42.5 R) and Portland blast – furnace cement (CEM II/A-S 42.2N). Cement hydration retarder was found to have a negative effect on freeze-thaw and deicing salt resistance of concrete

1 October 2021 in Construction and Building Materials
Verified
Journal Article
Closed access
EKEkaterina Karpova
Ekaterina Karpova
Gintautas SkripkiunasGintautas Skripkiunas
Gintautas Skripkiunas
IBIrmantas Barauskas
Irmantas Barauskas
IBIeva Barauskienė
Ieva Barauskienė
Jakub HodulJakub Hodul
Jakub Hodul

14 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
DKDalius Kriptavičius
Dalius Kriptavičius
GGGiedrius Girskas
Giedrius Girskas
Gintautas SkripkiunasGintautas Skripkiunas
Gintautas Skripkiunas
The study investigates effect of the additive consisting of natural zeolite (clinoptilolite) and soda lime glass powder on the hydration, mechanical properties and porosity of Portland cement concrete. The effect of mineral additive on the technological, physical-mechanical properties and porosity of the mortar was investigated by increasing the content of natural zeolite and glass powder added to the mortar up to 20% by weight of cement in increments of 5% and different particles size of natural zeolite. The mixes with the best technological and mechanical properties were identified and further studies were conducted by replacing 10% and 15% of cement with natural zeolite and soda lime glass with an average grain size of 59.3 μm, 29.0 μm or 3.6 μm of zeolite, and 29.6 μm of glass powder. The hydration process and microstructure of hardened cement paste modified with the aforementioned mineral additives was analysed by microcalorimetry, X-ray diffraction tests and thermogravimetric analysis. The optimal composition of cement paste and particle size distribution of natural zeolite were determined to achieve the higher flexural and compressive strength and lower open porosity. The mixture of mineral additives has the highest effect in terms of flexural and compressive strength and open porosity when added at the proportion 75:15:10 (cement:natural zeolite:soda lime glass) and when zeolite with an average particle size of about 3.6 μm is used

21 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
Aigerim TolegenovaAigerim Tolegenova
Aigerim Tolegenova
Gintautas SkripkiunasGintautas Skripkiunas
Gintautas Skripkiunas
LRLyudmyla Rishko
Lyudmyla Rishko
KAKenzhebek Akmalaiuly
Kenzhebek Akmalaiuly
The influence of a complex application of both plasticizing and air-entraining effects on concrete with polycarboxylate ether superplasticizer (PCE), air-entraining admixture (AIR), or an anti-foaming agent (AF) is analyzed in this paper with considerations for on the air content, workability, flexural and compressive strength, and freezing–thawing resistance of hardened cement mixtures. The effect of the complex behavior of PCE, AIR, and AF on the porosity of hardened cement mortar (HCM) and freezing–thawing resistance was investigated; freezing–thawing resistance prediction methodology for plasticized mortar was also evaluated. The results presented in the article demonstrate the beneficial influence of entrained air content on consistency and stability of cement mortar, closed porosity, and durability of concrete. Freezing–thawing factor KF depending on porosity parameters can be used for freezing–thawing resistance prediction. With both plasticizing (decrease in the water–cement ratio) and air-entraining effects (increase in the amount of entrained air content), the frost resistance of concrete increases, scaling decreases exponentially, and it is possible to obtain great frost resistance for cement-based material.

1 September 2014 in Construction and Building Materials
Verified
Journal Article
Closed access
DNDzigita Nagrockiene
Dzigita Nagrockiene
GGGiedrius Girskas
Giedrius Girskas
Gintautas SkripkiunasGintautas Skripkiunas
Gintautas Skripkiunas

29 September 2015 in Journal of Environmental Engineering and Landscape Management
Verified
Journal Article
Open access
Jurgita MalaiskieneJurgita Malaiskiene
Jurgita Malaiskiene
DNDžigita Nagrockienė
Džigita Nagrockienė
Gintautas SkripkiunasGintautas Skripkiunas
Gintautas Skripkiunas
The goal of the study was to determine the effect of waste tire cord yarn with attached rubber particles on the properties of concrete made of different types of cement (Portland cement without additives – CEM I, Portland cement with limestone additive – CEM II). The filament waste (added at 0%, 2%, 4%, 6%, 8%, and 10% of the amount of fine aggregate) is water absorbing textile fibre additive with rubber particles, therefore a bigger amount of water is required to prepare the concrete mixture. With waste additive, the density and compressive strength of concrete reduces, but water absorption increases. The forecasted freeze-thaw resistance of concrete with cement type CEM I and recycled tire cord increases and slightly reduces when cement type CEM II is used, however retains similar resistance in about 1000 freeze-thaw cycles. The coefficient of thermal conductivity decreases approx. 35%, when 10% of recycled tire textile cord is added to concrete mixture.