Srivathsan Vasudevan

Srivathsan Vasudevan


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2019 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
AGAbhijeet Gorey
Abhijeet Gorey
PJPaul M Jacob
Paul M Jacob
DADeepak T Abraham
Deepak T Abraham
RJReetu John
Reetu John
MMMarie T Manipadam
Marie T Manipadam
SVSrivathsan Vasudevan
Srivathsan Vasudevan
Thyroid nodule (TN), a discrete palpable swelling of the thyroid gland, is prevalent among 8% of the adult population. The important concern with these nodules is the differentiation between benign and malignant ones. Since conventional diagnostic techniques (e.g., ultrasound) are not accurate in diagnosis, clinical surgeons adopt to excision biopsy, a golden standard, which requires surgery and removal of the gland. We propose to apply Photoacoustic Spectral Response (PASR), a non-invasive and elasticity based diagnostic technique, onto TN for malignancy diagnosis. In this study, time domain photoacoustic signals were acquired through custom built experimental setup inside the surgical theatre and spectral information were obtained through signal processing. PA spectra could distinguish Follicular Variant of Papillary Thyroid Carcinoma (a thyroid cancer) from the other tissues with a high accuracy which an important challenge in conventional diagnostic techniques. Further, other tissue variants were also successfully differentiated through signal decomposition in a quantitative manner.

22 August 2018 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
AGAbhijeet Gorey
Abhijeet Gorey
DBDeblina Biswas
Deblina Biswas
AKAnshu Kumari
Anshu Kumari
SGSharad Gupta
Sharad Gupta
NSNorman Sharma
Norman Sharma
SVSrivathsan Vasudevan
Srivathsan Vasudevan

1 July 2011 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
GCGeorge Chung-Kit Chen
George Chung-Kit Chen
CWChi Lok Wong
Chi Lok Wong
BNBeng Koon Ng
Beng Koon Ng
SVSrivathsan Vasudevan
Srivathsan Vasudevan
SAShuchi Agarwal
Shuchi Agarwal
ZLZhiping Lin
Zhiping Lin
In this paper, a full-field photothermal imaging technique, which does not require a time consuming scan as used in the conventional photothermal imaging system, is reported. Imaging on gold nanoparticles (70 nm) and a blue polystyrene bead (193 nm) were conducted and the experimental results demonstrate the visualization ability of the photothermal imaging technique on nanotargets that are below the diffraction limit. The photothermal imaging system can be operated in an ambient environment where vacuum is not required.

3 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
DBDeblina Biswas
Deblina Biswas
Swarup RoySwarup Roy
Swarup Roy
SVSrivathsan Vasudevan
Srivathsan Vasudevan
The photoacoustic (PA) technique is a non-invasive, non-ionizing hybrid technique that exploits laser irradiation for sample excitation and acquires an ultrasound signal generated due to thermoelastic expansion of the sample. Being a hybrid technique, PA possesses the inherent advantages of conventional optical (high resolution) and ultrasonic (high depth of penetration in biological tissue) techniques and eliminates some of the major limitations of these conventional techniques. Hence, PA has been employed for different biomedical applications. In this review, we first discuss the basic physics of PA. Then, we discuss different aspects of PA techniques, which includes PA imaging and also PA frequency spectral analysis. The theory of PA signal generation, detection and analysis is also detailed in this work. Later, we also discuss the major biomedical application area of PA technique.

1 November 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
AGAbhijeet Gorey
Abhijeet Gorey
SVSrivathsan Vasudevan
Srivathsan Vasudevan
MAM. S. Ansari
M. S. Ansari
PBPriyanka Bhagat
Priyanka Bhagat
SPSatish Phatak
Satish Phatak
GCGeorge C. K. Chen
George C. K. Chen
We present the development of a laser diode based photoacoustic spectral response (PASR) setup capable of diagnosing human breast cancer tissues through the use of mechanobiological properties of the tissue. A detailed description of the laser driver is provided, highlighting the important characteristics of the developed driver. Furthermore, the amplifier development is described. The developed laser diode based PASR system has been characterized using standard samples. Subsequently, the developed experiment has been applied onto diagnosis of human breast tumors. Energy has been used as a parameter to differentiate between normal and malignant tissues. The results were statistically consistent and then compared with standard histopathology for correlation.

8 September 2017 in Applied Spectroscopy
Verified
Journal Article
Closed access
DBDeblina Biswas
Deblina Biswas
AKAnshu Kumari
Anshu Kumari
GCGeorge C. K. Chen
George C. K. Chen
SVSrivathsan Vasudevan
Srivathsan Vasudevan
SGSharad Gupta
Sharad Gupta
UGUmesh K. Garg
Umesh K. Garg
Pneumonia is an acute lung infection that takes life of many young children in developing countries. Early stage (red hepatization) detection of pneumonia would be pragmatic to control mortality rate. Detection of this disease at early stages demands the knowledge of pathology, making it difficult to screen noninvasively. We propose photoacoustic spectral response (PASR), a noninvasive elasticity-dependent technique for early stage pneumonia detection. We report the quantitative red hepatization detection of pneumonia through median frequency, spectral energy, and variance. Significant contrast in spectral parameters due to change in sample elasticity is found. The tissue-mimicking phantom study illustrates a 39% increase in median frequency for 1.5 times the change in density. On applying to formalin-fixed pneumonia-affected goat lungs, it provides a distinct change in spectral parameters between pneumonia affected areas and normal lungs. The obtained PASR results were found to be highly correlating to standard histopathology. The proposed technique therefore has potential to be a regular diagnostic tool for early pneumonia detection.