Tao Li

Prof. Tao Li

Department of Electrical Engineering and Computer Science, University of Cincinnati, Cincinnati, Ohio 45221-0030, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
TLTao Li
Tao Li
ABAdam Barnett
Adam Barnett
KRKaren L. Rogers
Karen L. Rogers
YGYogesh B. Gianchandani
Yogesh B. Gianchandani
This paper describes a microsystem for automated blood sampling from laboratory mice used in pharmacokinetic studies. Intended to be mounted as a “backpack” on a mouse, it uses a microneedle, reservoir, and an actuator to instantaneously prick the animal for a time-point sample, eliminating the need for a tethered catheter with large dead volume. The blood is collected by capillary effect through a 31–33 gauge microneedle (250–210 μm OD) into a ≈1 μL micromachined steel reservoir. The voice coil actuator provides a peak force of ≈300 mN, which amply exceeds the measured piercing force of mouse skin (i.e., 60–85 mN for a 31-gauge needle with 12° bevel). The sampling system was tested in vitro using a mock vessel with adjustable pressure; the reservoir was filled in <0.15 s by a combination of the capillary effect and blood pressure. The system may also be used to sample interstitial fluid, but the absence of blood pressure makes it necessary to enhance the capillary effect of the needle. This is accomplished by either electropolishing the inner surface to make it more hydrophilic or using a polymer wire insert to increase the surface area. The steel surface of the reservoir is also coated with silicon oxynitride by plasma-enhanced chemical vapor deposition to improve its hydrophilicity. Blood from fresh bovine tissue was collected into the reservoir to simulate interstitial fluid sampling. In vivo tests on live, anesthetized mice resulted in successful collection of blood into the reservoir. The possible integration of the device in microanalytical systems and the device scalability for multisampling are discussed.

5 June 2006 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
TLTao Li
Tao Li
YGY.B. Gianchandani
Y.B. Gianchandani
This paper reports on a batch mode planar pattern transfer process for bulk ceramics, glass, and other hard, brittle, nonconductive materials suitable for micromachined transducers and packages. The process is named LEEDUS, as it combines lithography, electroplating, batch mode micro electro-discharge machining (/spl mu/EDM) and batch mode micro ultrasonic machining (/spl mu/USM). An electroplating mold is first created on a silicon or metal wafer using standard lithography, then using the electroplated pattern as an electrode to /spl mu/EDM a hard metal (stainless steel or WC/Co) tool, which is finally used in the /spl mu/USM of the ceramic substrate. A related process (SEDUS) uses serial /spl mu/EDM and omits lithography for rapid prototyping of simple patterns. Feature sizes of 25 /spl mu/m within a 4.5/spl times/4.5 mm/sup 2/ die have been micromachined on glass-mica (Macor) ceramic plates with 34 /spl mu/m depth. The ultrasonic step achieves 18 /spl mu/m/min. machining rate, with a tool wear ratio of less than 6% for the stainless steel microtool. Other process characteristics are also described. As a demonstration, octagonal and circular spiral shaped in-plane actuators were fabricated from bulk lead zirconate titanate (PZT) plate using the LEEDUS/SEDUS process. A device of 20 /spl mu/m thickness and 450 /spl mu/m/spl times/420 /spl mu/m footprint produces a displacement of /spl ap/2/spl mu/m at 40 V.

1 March 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
AGAngelo Gaitas
Angelo Gaitas
RMRicky Malhotra
Ricky Malhotra
TLTao Li
Tao Li
THTodd Herron
Todd Herron
Jose JalifeJose Jalife
Jose Jalife
Cardiac contractility is the hallmark of cardiac function and is a predictor of healthy or diseased cardiac muscle. Despite advancements over the last two decades, the techniques and tools available to cardiovascular scientists are limited in their utility to accurately and reliably measure the amplitude and frequency of cardiomyocyte contractions. Isometric force measurements in the past have entailed cumbersome attachment of isolated and permeabilized cardiomyocytes to a force transducer followed by measurements of sarcomere lengths under conditions of submaximal and maximal Ca2+ activation. These techniques have the inherent disadvantages of being labor intensive and costly. We have engineered a micro-machined cantilever sensor with an embedded deflection-sensing element that, in preliminary experiments, has demonstrated to reliably measure cardiac cell contractions in real-time. Here, we describe this new bioengineering tool with applicability in the cardiovascular research field to effectively and reliably measure cardiac cell contractility in a quantitative manner. We measured contractility in both primary neonatal rat heart cardiomyocyte monolayers that demonstrated a beat frequency of 3 Hz as well as human embryonic stem cell-derived cardiomyocytes with a contractile frequency of about 1 Hz. We also employed the β-adrenergic agonist isoproterenol (100 nmol l−1) and observed that our cantilever demonstrated high sensitivity in detecting subtle changes in both chronotropic and inotropic responses of monolayers. This report describes the utility of our micro-device in both basic cardiovascular research as well as in small molecule drug discovery to monitor cardiac cell contractions.

1 January 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
TLTao Li
Tao Li
RGRoma Y. Gianchandani
Roma Y. Gianchandani
YGYogesh B. Gianchandani
Yogesh B. Gianchandani
This paper describes a micromachined piezoelectric sensor, integrated into a cavity at the tip of a biopsy needle, and preliminary experiments to determine if such a device can be used for real-time tissue differentiation, which is needed for needle positioning guidance during fine needle aspiration (FNA) biopsy. The sensor is fabricated from bulk lead zirconate titanate (PZT), using a customized process in which micro electro-discharge machining is used to form a steel tool that is subsequently used for batch-mode ultrasonic micromachining of bulk PZT ceramic. The resulting sensor is 50 µm thick and 200 µm in diameter. It is placed in the biopsy needle cavity, against a steel diaphragm which is 300 µm diameter and has an average thickness of 23 µm. Devices were tested in materials that mimic the ultrasound characteristics of human tissue, used in the training of physicians, and with porcine fat and muscle tissue. In both schemes, the magnitude and frequency of an electrical impedance resonance peak showed tissue-specific characteristics as the needle was inserted. For example, in the porcine tissue, the impedance peak frequency changed ≈13 MHz from the initial 163 MHz, and the magnitude changed ≈1600 Ω from the initial 2100 Ω, as the needle moved from fat to muscle. Samples including oils and saline solution were tested for calibration, and an empirical tissue contrast model shows an approximately proportional relationship between measured frequency shift and sample acoustic impedance. These results suggest that the device can complement existing methods for guidance during biopsies.

23 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MCMyungjoon Choi
Myungjoon Choi
YSYu Sui
Yu Sui
Inhee LeeInhee Lee
Inhee Lee
RMRyan Meredith
Ryan Meredith
YMYushu Ma
Yushu Ma
TLTao Li
Tao Li
This paper describes two platforms for autonomous sensing microsystems that are intended for deployment in chemically corrosive environments at elevated temperatures and pressures. Following the deployment period, the microsystems are retrieved, recharged, and interrogated wirelessly at close proximity. The first platform is the Michigan Micro Mote for High Temperature (M3HT), a chip stack 2.9 × 1.1 × 1.5 mm3 in size. It uses RF communications to support pre-deployment and post-retrieval functions, and it uses customized electronics to achieve ultralow power consumption, permitting the use of a chip-scale battery. The second platform is the Environmental Logging Microsystem (ELM). This system, which is 6.5 × 6.3 × 4.5 mm3 in size, uses the smallest suitable off-the-shelf electronic and battery components that are compatible with assembly on a flexible printed circuit board. Data are stored in non-volatile memory, permitting retrieval even after total power loss. Pre-deployment and post-retrieval functions are supported by optical communication. Two types of encapsulation methods are used to withstand high pressure and corrosive environments: an epoxy filled volume is used for the M3HT, and a hollow stainless-steel shell with a sapphire lid is used for both the M3HT and ELM. The encapsulated systems were successfully tested at temperature and pressure reaching 150 °C and 10,000 psi, in environments of concentrated brine, oil, and cement slurry. At elevated temperatures, the limited lifetimes of available batteries constrain the active deployment period to several hours.

14 May 2014 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
AVAnupam Viswanath
Anupam Viswanath
TLTao Li
Tao Li
YGYogesh Gianchandani
Yogesh Gianchandani