Pietro Pasini

Dr. Pietro Pasini

University of Insubria, Department of Biotechnology and Life Sciences, Varese, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
Davide FarronatoDavide Farronato
Davide Farronato
PPPietro Pasini
Pietro Pasini
AOAndrea Alain Orsina
Andrea Alain Orsina
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
LALorenzo Azzi
Lorenzo Azzi
Marco FarronatoMarco Farronato
Marco Farronato
Background: Optimal aesthetic implant restoration is a combination of a visually pleasing prosthesis and adequate surrounding peri-implant soft tissue architecture. This study describes the influence of the residual buccal bone thickness (BBT), measured at the time of implant placement, on the soft tissue maturation during three years of follow-up. Methods: Seventy-eight implants were enrolled in the present study. The BBT was assessed at the surgical stage and each case assigned to Group 1 (BBT values ≤0.5 mm), Group 2 (BBT values >0.5 and 0.5 and <1.5 mm, the buccal gum also showed recession of 0.64 ± 0.29 mm. In contrast, for BBT values ≥1.5 mm, the buccal gum showed coronal growth of 0.77 ± 0.22 mm. The differences between the groups were significant (p ≤ 0.01) at all times. Conclusion: The BBT at the time of implant placement was found to affect the buccal gingival margin stability over three years of observation.

2 April 2019 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Davide FarronatoDavide Farronato
Davide Farronato
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
FMFrancesco Mangano
Francesco Mangano
GGGiada Goffredo
Giada Goffredo
MCMarco Colombo
Marco Colombo
Marco FarronatoMarco Farronato
Marco Farronato
Background: Previous studies have suggested that mucosal height is related to the bone level and soft tissue thickness. The purpose of this pilot study was to investigate the ratio between the height and width of the tissues around single implants with a conical connection and platform switching. Methods: All patients receiving single implants (Anyridge®, MegaGen, Gyeongbuk, South Korea) and restored with single crowns, in a three-month period, were included in this study. After a provisionalization of 12 months, precision impressions were taken and stone casts were poured for measurements. For each implant, two values were collected at the buccal site: the mucosal height (MH), calculated from the vestibular shoulder of the implant to the upper gingival margin of the supra-implant tissue; and the mucosal thickness (MT), calculated from the vestibular shoulder of the analogue to the external mucosa point perpendicular to the implant major axis. Mean, standard deviation (SD), and confidence intervals (CI 95%) for MH and MT, as well as their ratios, were calculated. Correlation between MH and MT was assessed by Pearson’s correlation coefficient, with significance level set at 0.05. Results: 32 single Anyridge® implants were eligible for this evaluation. The mean MH was 3.44 mm (±1.28), the mean MT was 3.29 (±1.46). The average of the ratio between MH and MT of the supra-implant mucosa was therefore 1:1.19 (±0.55). The relation between MH and MT was statistically significant at p ≤ 0.01 (Pearson two-tailed 95% CI). Conclusions: Our study found a constant relationship between width and height of the peri-implant mucosa. However, our results are different from those of Nozawa et al., who found a ratio of 1:1.5 between height and thickness of the peri-implant tissues. This may be determined by the different sample and follow-up period, as well as by the implants used in our study.

Verified
Journal Article
Open access
PDF file
Davide FarronatoDavide Farronato
Davide Farronato
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Marco FarronatoMarco Farronato
Marco Farronato
PPPietro Pasini
Pietro Pasini
AOAndrea Alain Orsina
Andrea Alain Orsina
Diego  Lops Diego Lops
Diego Lops
To verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed. Additionally, the presence of keratinized facial mucosa and the prosthetic crown height (TH) were monitored for three years from the delivery of the definitive crown. These parameters were measured for two different groups: platform-switched implants in the PS group and non-platform-switched (NPS) implants in the NPS group. Seventy-seven implants were considered in the statistical analysis. After three years, the overall FBIC mean value was 0.31 ± 1.00 mm. However, the mean FBIC was 0.66 ± 0.97 mm for the NPS group and −0.05 ± 0.91 mm for the PS group. Moreover, a mean recession of 0.54 ± 1.39 mm was measured for the NPS group, whereas a mean coronal migration of 0.17 ± 0.95 mm was measured for the PS group. A significant correlation was also found between the presence of PS and ΔTH (p ≤ 0.01) over the three years of follow-up. The absence or presence of platform-switching would appear to affect the tendency of the gingival buccal margin towards recession or creeping. Additionally, implant-abutment platform-switching seems to help prevent peri-implant soft tissue recession over time when compared to implants without PS.

17 February 2020 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Davide FarronatoDavide Farronato
Davide Farronato
PPPietro Pasini
Pietro Pasini
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Cristian ScognamiglioCristian Scognamiglio
Cristian Scognamiglio
AOAndrea Alain Orsina
Andrea Alain Orsina
Marco FarronatoMarco Farronato
Marco Farronato
Background: To compare tissue response to two implant systems, featuring internal hexed connections with different designs. Methods: Patients enrolled in this randomized controlled trial were assigned to two groups. In Group 1, patients were treated with implants with a 5° conical internal hexed connection (Anyridge®, MegaGen, South Korea). In Group 2, patients were treated with implants with an internal hexed connection (Core®, Kristal, Italy). After implant placement and a provisionalisation period of 12 months, impressions were taken, stone casts were poured and digitised with a desktop scanner (D700®, 3Shape, Copenhagen, Denmark). In a digital environment, for each fixture, two values were collected at the buccal zenith: the height of the peri-implant mucosa (mucosal height; MH), calculated from the vestibular shoulder of the implant analogue to the upper gingival margin of the supra-implant tissue; and the width of the peri-implant mucosa (mucosal thickness; MT), calculated from the vestibular shoulder of the analogue to the external mucosa point perpendicular to the implant major axis. The mean and standard deviation for MH and MT, as well as their ratios, were calculated for each group; the sectors in which the implants were placed were also considered. Finally, correlation between MH, MT, connection type and sector was assessed by Pearson’s correlation coefficient, with significance level set at 0.05, and a confidence interval (CI) set at 95%. Results: Data deriving from 188 implants placed in 104 patients were evaluated. The mean MH values were 3.32 (± 0.12) and 2.70 (± 0.16) mm for Groups 1 and 2, respectively. The mean MT values were 4.37 (± 0.16) and 3.93 (± 0.18) mm for Groups 1 and 2, respectively. Group 1 showed higher MH and MT values and a better ratio (1.50 ± 0.88) than Group 2 (1.81 ± 1.20). The MH, MT and MH/MT ratio were significantly influenced both by sector (p = 0.015) and group (p = 0.047). Conclusions: Within the limits of this study, the 5° connection implants supported a more extended tissue height and thickness at the buccal zenith, and a better ratio between them. Trial registration: This study was retrospectively registered in Clinicaltrials.gov, with number NCT04160689, dated 13/11/2019.

1 March 2018 in International Journal of Periodontics & Restorative Dentistry
Verified
Journal Article
Closed access
Davide FarronatoDavide Farronato
Davide Farronato
DFDavide Fumagalli
Davide Fumagalli
FAFarah Asa’AD
Farah Asa’AD
PPPietro Pasini
Pietro Pasini
FMFrancesco Mangano
Francesco Mangano
GRGiulio Rasperini
Giulio Rasperini
Davide Farronato, DDS, PhD, PD, AP/Davide Fumagalli, DDS/Farah Asa?ad, BDS, MSc, PhD/Pietro M. Pasini, DMD/Francesco Mangano, DDS, PhD, FICD/Giulio Rasperini, DDS: This report describes a failed blade implant after 25 years in function in the left maxilla and the results of histologic analysis of peri-implant tissues. The blade was retrieved, and histologic findings revealed that it was not osseointegrated despite being successfully in function for so many years. The long-term function of blade implants without osseointegration can be attributed to biotolerance exhibited by the implant rather than actual osseointegration.

30 June 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Davide FarronatoDavide Farronato
Davide Farronato
GMGiuseppe Messina
Giuseppe Messina
LLLuciano Laveglia
Luciano Laveglia
PPPietro Pasini
Pietro Pasini
LALorenzo Azzi
Lorenzo Azzi
Marco FarronatoMarco Farronato
Marco Farronato
Background: The behavior of soft tissues following recession type 1 (RT1) and/or non-carious cervical lesions (NCCLs) treated with class V restorations is not well understood. These conditions cause both functional and esthetic issues. Recent studies show that increased cervical thickness can influence gingival tissue response. This suggests that restoration design has a key impact. This study aims to evaluate the effect of tooth shape modification on gingival tissue response and periodontal health with 3D analysis. Methods: Seven patients with buccal gingival recession and NCCL were selected, resulting in 50 treated teeth. Patients underwent class V buccal restorations using the BOVR technique. Three-dimensional evaluation through scanned dental impressions was performed at baseline and at T1 to monitor tissue profile changes in the buccal zenith sagittal plane. The average observation period was 4 months. Following the assessment, linear measurements were calculated according to standard planes. These measurements aimed to monitor transverse and axial tissue modifications. Probing depth, plaque index, and bleeding index were also recorded. Results: Increased tooth thickness led to tissue alteration. Greater composite thickness was significantly associated with an increase in tissue thickness (p ≤ 0.001) and gingival creeping (p ≤ 0.001) at the free gingival margin. Periodontal health remained unaffected, and 50% of the teeth required no additional surgical treatment due to satisfactory outcomes. Conclusions: Class V restorations that increase cervical thickness may promote soft tissue volume gain over a 4-month period without compromising periodontal health. A 4-month observation period is recommended before considering the surgical correction.