Voids or cracks in basin insulators inside a GIS (gas-insulated metal-enclosed switchgear) could trigger partial discharges or surface flashover under electrical stresses, threatening safe GIS operation. For this paper, some epoxy composite specimens were made from similar materials and manufacturing processes to make 252 kV GIS basin insulators. Some voids with different diameters or cracks with different diameters and orientations were artificially made in the specimens with different thicknesses. An ultrasonic pulse-echo system was set up, and ultrasonic tests were carried out on the specimens with voids or cracks. A method to calculate the depth of a defect was proposed by the propagation time of defect reflected waves. The results showed that a depth of 50 mm, a diameter φ of 2 mm void, and a diameter φ of 1 mm crack in epoxy composite insulation were detected by the ultrasonic system using a 1 MHz transducer.
Situations of internal stress in basin insulators inside gas-insulated metal-enclosed switchgear (GIS) can lead to cracks, which can influence the safety and stability of apparatus. However, there is currently no research on internal stress measurements for composites of GIS basin insulators, and only measurements for surface stress. In this paper, an internal stress measurement method for GIS epoxy composite is proposed using an ultrasonic longitudinal through-transmission technique based on the acoustoelastic effect. An internal stress measurement system is developed to investigate the relationship between the uniaxial compressive internal stress and the velocity of the ultrasonic wave vertical to the stress in epoxy composite within a range of 0–70 MPa, and to calculate the acoustoelastic coefficient of epoxy composite. The effects of system delay are eliminated in measuring the propagation time. Some epoxy composite cuboid specimens with similar materials and using a manufacturing process similar to those of 252 kV GIS basin insulators are synthesized, and the uniformity of the internal stress in cuboid specimens is verified by finite element simulation. The results reveal a linear increase of the ultrasonic longitudinal wave velocity with increasing stress. It has been shown that the average acoustoelastic coefficient of GIS epoxy composites, using the longitudinal waves vertical to the stress, is 4.556 × 10−5/MPa. Additionally, the absolute errors of the internal stress measurements are less than 12.397 MPa. This research shows that the ultrasonic method based on the acoustoelastic effect for measuring the internal stress in GIS epoxy composites is feasible.
Internal stress in basin insulators of gas-insulated metal-enclosed switchgear (GIS) can lead to cracks, which affects the safe operation of these apparatuses. In this research, we proposed a subsurface internal stress measurement method for GIS epoxy composites. This method is based on an ultrasonic longitudinal critically refracted (LCR) wave technique. In this study, some epoxy composite specimens were synthesized with similar materials and manufacturing processes to those of 252 kV GIS basin insulators. An ultrasonic stress measurement system that utilized the LCR wave technique was set-up to investigate the relationship between stress and LCR wave propagation time, as well as to measure the compressive stress of the epoxy specimen within 0–50 MPa. The results show that LCR wave propagation time linearly decreased when stress increased in the subsurface zone and the acoustoelastic coefficient was −4.95. We found the relative errors of stress measurements to be less than 13%.
16 October 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
The internal defects in composite insulators, for example void, delamination, and interface debonding, can lead to partial discharge, flashover, and even result in cracking and breakdown, threatening the safe operation of power system. In this study, various defects were artificially made in the 10 kV composite insulators. The ultrasonic phased array method was employed to detect these defects, by using a concave probe designed to ensure complete coupling between the probe detection surface and the curved insulator surface. The results show that these artificial defects can be detected through the detection ultrasonic images. Moreover, compared to previous studies, a smaller through-hole (0.3 mm diameter) in the housing and a smaller through-hole (0.5 mm diameter) in the core can be successfully detected. Additionally, the depths of defects can be determined from the detection images, and the deviations in depth for the defects were less than 9.3%. Moreover, the resolution for detecting the through-holes in the housing is enhanced.
The mechanical reliability of the gas-insulated metal-enclosed switchgear (GIS) is critical to the safe and stable operation of a power system. The internal stress induced in GIS insulators, which typically lead to cracking, can degrade the mechanical properties and compromise the reliability of the GIS. In this work, ultrasonic nondestructive measurements of the internal stress in a GIS 126 kV epoxy composite with the transverse waves are demonstrated for the first time. Our results show that the velocities of ultrasonic transverse waves increase linearly with the compressive stress and decrease linearly with the tensile stress. The acoustoelastic coefficients are −1.18 × 10−4/MPa and −1.96 × 10−4/MPa for measurements with transverse waves polarized vertically and parallelly to stress, respectively. Based on these acoustoelastic coefficients, the internal stresses are calculated, and the maximum absolute values of relative errors are 35.4% and 26.3% for measurements with the transverse wave polarized vertically and parallelly to stress, respectively.