The current study investigated Listeria monocytogenes inactivation using mild heat with elevated hydrostatic pressure and nisin under buffered condition. A four-strain pathogen mixture was exposed to 0 (control) and up to 9 min of (1) 4 °C elevated pressure; (2) 4 °C elevated pressure and nisin; (3) 4 °C nisin; (4) heat at 40 °C; (5) 40 °C elevated pressure; (6) 40 °C elevated pressure and nisin; and (7) 40 °C nisin. Elevated hydrostatic pressure at 400 MPa (Hub880 Explorer, Pressure BioScience Inc., Easton, MA, USA) and nisin concentration of 5000 IU/mL were used in the trials. Analyses of variance were conducted, followed by Dunnett’s- and Tukey-adjusted means separations. Under conditions of these experiments, nisin augmented (p < 0.05) decontamination efficacy of 40 °C heat and elevated hydrostatic pressure treatments, particularly at treatment interval of 3 min. This synergism with nisin faded away (p ≥ 0.05) as the treatment time for thermal, high-pressure, and thermal-assisted pressure processing increased. The results of our study, thus, exhibit that practitioners and stakeholders of pressure-based technologies could benefit from synergism of mild heat and nisin for short-term, high-pressure pasteurization treatments to achieve microbial safety and economic feasibility comparable to traditional heat-treated products.
Since the historic outbreak near Broad Street in London, which serves as cornerstone of modern epidemiology, infectious diseases spread in surface and sub-surface water has been a persisting public health challenge. The current study investigated persistence of wild-type and pressure-stressed Listeria monocytogenes, Escherichia coli O157:H7, and non-typhoidal Salmonella enterica serovars in surface water stored aerobically for up to 28 days at 5, 25, and 37 °C. Additionally, biofilm formation of wild-type and pressure-stressed non-typhoidal Salmonella serovars were monitored on surface of stainless steel and rubber coupons for 28 days at 25 and 37 °C. While L. monocytogenes exhibited a lower (p < 0.05) survival rate at 5 °C, relative to the two Gram-negative pathogens, at higher temperatures of 25 and 37 °C, all three pathogens exhibited similar (p ≥ 0.05) trends for survival in surface water. Both wild-type and pressure-stressed Salmonella serovars in the vast majority of tested times, temperatures, and surfaces exhibited comparable (p ≥ 0.05) persistence and biofilm formation capability. Our study thus indicates the occurrence of contamination could lead to prolonged survival of these microorganisms in low-nutrient environments and highlights the need for preventive measures such as those articulated under Produce Safety Rule of the U.S. Food Safety Modernization Act.
Current study investigated effects of elevated hydrostatic pressure exposure in the presence of mild heat and natural antimicrobials against Staphylococcus aureus. Hydrostatic pressure of 350 to 550 MPa with nisin (5000 IU/mL), carvacrol, or caprylic acid (0.5% v/v) were applied for the reduction in four-strain mixture of S. aureus in HEPES buffer at 4 and 40 °C for up to 7 min. Results were statistically analyzed by ANOVA and D-values were additionally calculated using best-fitted linear model. Prior to exposure to treatments at 4 °C, counts of the pathogen were 7.95 ± 0.4 log CFU/mL and were reduced (p < 0.05) to 6.44 ± 0.3 log CFU/mL after 7 min of treatment at 450 MPa. D-value associated with this treatment was 5.34 min (R2 = 0.72). At 40 °C, counts were 8.21 ± 0.7 and 5.77 ± 0.3 log CFU/mL before and after the 7-min treatments, respectively. D-value associated with 40 °C treatment was 3.30 min (R2 = 0.62). Application of the antimicrobials provided additional pathogen reduction augmentation for treatments < 5 min. The results of the current study could be incorporated for meeting regulatory requirements such as Food Code, HACCP, and Preventive Control for Human Food of Food Safety Modernization Act for assuring microbiological safety of products against this prevalent pathogen of public health concern.