Ching-Chi Hsu

Prof. Ching-Chi Hsu

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
CLChian-Her Lee
Chian-Her Lee
CHChing-Chi Hsu
Ching-Chi Hsu
PHPo-Yuang Huang
Po-Yuang Huang

1 September 2016 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
PTPei-I Tsai
Pei-I Tsai
CHChing-Chi Hsu
Ching-Chi Hsu
SCSan-Yuan Chen
San-Yuan Chen
TWTsung-Han Wu
Tsung-Han Wu
CHChih-Chieh Huang
Chih-Chieh Huang

3 October 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CLChian-Her Lee
Chian-Her Lee
KSKao-Shang Shih
Kao-Shang Shih
CHChing-Chi Hsu
Ching-Chi Hsu
TCTomas Cho
Tomas Cho
Locking compression plates (LCPs) have been used to fix femoral shaft fractures. Previous studies have attempted to identify the best LCP screw positions and numbers to achieve the fixation stability. However, the determined screw positions and numbers were mainly based on the surgeons' experiences. The aim of this study was to discover the best number and positions of LCP screws to achieve acceptable fixation stability. Three-dimensional numerical models of a fractured femur with the LCP were first developed. Then, the best screw position and number of LCPs were determined by using a simulation-based particle swarm optimization algorithm. Finally, the results of the numerical study were validated by conducting biomechanical tests. The results showed that the LCP with six locking screws resulted in the necessary fixation stability, and the best combination of positions of locking screws inserted into the LCP was 1-5-6-7-8-12 (three locking screws on either side of the bone fragment with two locking screws as close as practicable to the fracture site). In addition, the numerical models and algorithms developed in this study were validated by the biomechanical tests. Both the numerical and experimental results can provide clinical suggestions to surgeons and help them to understand the biomechanics of LCP systems.

21 July 2015 in Medical Engineering & Physics
Verified
Journal Article
Closed access
KSKao-Shang Shih
Kao-Shang Shih
CHChing-Chi Hsu
Ching-Chi Hsu
SHSheng-Mou Hou
Sheng-Mou Hou
SYShan-Chuen Yu
Shan-Chuen Yu
CLChen-Kun Liaw
Chen-Kun Liaw
Spinal pedicle screw fixations have been used extensively to treat fracture, tumor, infection, or degeneration of the spine. Cannulated spinal pedicle screws with bone cement augmentation might be a useful method to ameliorate screw loosening. However, cannulated spinal pedicle screws might also increase the risk of screw breakage. Thus, the purpose of this study was to investigate the bending performance of different spinal pedicle screws with either solid design or cannulated design. Three-dimensional finite element models, which consisted of the spinal pedicle screw and the screw's hosting material, were first constructed. Next, monotonic and cyclic cantilever bending tests were both applied to validate the results of the finite element analyses. Finally, both the numerical and experimental approaches were evaluated and compared. The results indicated that the cylindrical spinal pedicle screws with a cannulated design had significantly poorer bending performance. In addition, conical spinal pedicle screws maintained the original bending performance, whether they were solid or of cannulated design. This study may provide useful recommendations to orthopedic surgeons before surgery, and it may also provide design rationales to biomechanical engineers during the development of spinal pedicle screws.

21 November 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SJShu-Yu Jhou
Shu-Yu Jhou
CHChing-Chi Hsu
Ching-Chi Hsu
JYJui-Chia Yeh
Jui-Chia Yeh
This paper proposes a dynamic drop weight impact simulation to predict the impact response of 3D printed polymeric sandwich structures using an explicit finite element (FE) approach. The lattice cores of sandwich structures were based on two unit cells, a body-centred cubic (BCC) and an edge-centred cubic (ECC). The deformation and the peak acceleration, referred to as the g-max score, were calculated to quantify their shock absorption characteristic. For the FE results verification, a falling mass impact test was conducted. The FE results were in good agreement with experimental measurements. The results suggested that the strut diameter, strut length, number and orientation, and the apparent material stiffness of the lattice cores had a significant effect on their deformation behavior and shock absorption capability. In addition, the BCC lattice core with a thinner strut diameter and low structural height might lead to poor shock absorption capability caused by structure collapse and border effect, which could be improved by increasing its apparent material stiffness. This dynamic drop impact simulation process could be applied across numerous industries such as footwear, sporting goods, personal protective equipment, packaging, or biomechanical implants.

1 December 2011 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
CHChing-Chi Hsu
Ching-Chi Hsu
JLJinn Lin
Jinn Lin
CCChing-Kong Chao
Ching-Kong Chao