Heyu Yin

Dr. Heyu Yin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
LLLin Li
Lin Li
HYHeyu Yin
Heyu Yin
AMAndrew J. Mason
Andrew J. Mason
The integration of biosensors, microfluidics, and CMOS instrumentation provides a compact lab-on-CMOS microsystem well suited for high throughput measurement. This paper describes a new epoxy chip-in-carrier integration process and two planar metalization techniques for lab-on-CMOS that enable on-CMOS electrochemical measurement with multichannel microfluidics. Several design approaches with different fabrication steps and materials were experimentally analyzed to identify an ideal process that can achieve desired capability with high yield and low material and tool cost. On-chip electrochemical measurements of the integrated assembly were performed to verify the functionality of the chip-in-carrier packaging and its capability for microfluidic integration. The newly developed CMOS-compatible epoxy chip-in-carrier process paves the way for full implementation of many lab-on-CMOS applications with CMOS ICs as core electronic instruments.

8 December 2025 in Nature Electronics
Verified
Journal Article
Open access
PDF file
TJTaesung Jung
Taesung Jung
NZNanyu Zeng
Nanyu Zeng
JFJason D. Fabbri
Jason D. Fabbri
GEGuy Eichler
Guy Eichler
ZLZhe Li
Zhe Li
KSKenneth L. Shepard
Kenneth L. Shepard
Electrocorticography uses non-penetrating electrodes embedded in flexible substrates to record electrical activity from the surface of the brain. To use the technology to develop minimally invasive, high-bandwidth brain–computer interfaces, it will be necessary to improve the number of recording channels and the scalability of devices, which could be achieved by merging electrodes and electronics onto a single substrate. Here we report a 50-μm-thick, mechanically flexible micro-electrocorticography brain–computer interface that integrates a 256 × 256 array of electrodes, signal processing, data telemetry and wireless powering on a single complementary metal–oxide–semiconductor substrate. The device contains 65,536 recording electrodes, from which we can simultaneously record a selectable subset of up to 1,024 channels at a given time. Our chip is wirelessly powered, and when implanted below the dura, it can communicate bidirectionally with an external relay station outside the body. We show that the device can provide chronic, reliable recordings for up to two weeks in pigs and up to two months in behaving non-human primates from the somatosensory, motor and visual cortices, decoding brain signals at high spatiotemporal resolution.

10 June 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HYHeyu Yin
Heyu Yin
EAEhsan Ashoori
Ehsan Ashoori
XMXiaoyi Mu
Xiaoyi Mu
AMAndrew J. Mason
Andrew J. Mason
This paper introduces a novel compact low-power amperometric instrumentation design with current-to-digital output for electrochemical sensors. By incorporating the double layer capacitance of an electrochemical sensor's impedance model, our new design can maintain performance while dramatically reducing circuit complexity and size. Electrochemical experiments with potassium ferricyanide show that the circuit output is in a good agreement with results obtained using commercial amperometric instrumentation. A high level of linearity (R 2 = 0.991) between the circuit output and the concentration of potassium ferricyanide was also demonstrated. Furthermore, we show that a CMOS implementation of the presented architecture could save 25.3% of the area and 47.6% of power compared to a traditional amperometric instrumentation structure. Thus, this new circuit structure is ideally suited for portable/wireless electrochemical sensing applications.

6 August 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HYHeyu Yin
Heyu Yin
XMXiaoyi Mu
Xiaoyi Mu
HLHaitao Li
Haitao Li
XLXiaowen Liu
Xiaowen Liu
AMAndrew J. Mason
Andrew J. Mason
The growing demand for personal healthcare monitoring requires a challenging combination of performance, size, power, and cost that is difficult to achieve with existing gas sensor technologies. This paper presents a new CMOS monolithic gas sensor microsystem that meets these requirements through a unique combination of electrochemical readout circuits, post-CMOS planar electrodes, and room temperature ionic liquid (RTIL) sensing materials. The architecture and design of the CMOS-RTIL-based monolithic gas sensor are described. The monolithic device occupies less than 0.5 mm 2 per sensing channel and incorporates electrochemical biasing and readout functions with only 1.4 mW of power consumption. Oxygen was tested as an example gas, and results show that the microsystem demonstrates a highly linear response (R 2 = 0.995) over a 0-21% oxygen concentration range, with a limit of detection of 0.06% and a 1 s response time. Monolithic integration reduces manufacturing cost and is demonstrated to improve limits of detection by a factor of five compared to a hybrid implementation. The combined characteristics of this device offer an ideal platform for portable/wearable gas sensing in applications such as air pollutant monitoring.

12 August 2024 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
EPEric H. Pollmann
Eric H. Pollmann
HYHeyu Yin
Heyu Yin
IUIlke Uguz
Ilke Uguz
ADAgrita Dubey
Agrita Dubey
KWKatie E. Wingel
Katie E. Wingel
KSKenneth L. Shepard
Kenneth L. Shepard

1 November 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Hao WanHao Wan
Hao Wan
HYHeyu Yin
Heyu Yin