Jun Jiang

Jun Jiang

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JJJun Jiang
Jun Jiang
WLWei Li
Wei Li
ZWZhe Wen
Zhe Wen
YBYifan Bie
Yifan Bie
HSHarald Schwarz
Harald Schwarz
CZChaohai Zhang
Chaohai Zhang
Series arc is prone to cause fire accidents, but its occurrences induced by different load types and connections make the detection challengeable. This paper proposes a series arc fault detection and location algorithm for multi-load circuit topology, especially for branch arc faults and nonlinear power loads. Several typical loads of paralleling connected are considered to measure the current changes caused by the arcing phenomenon at different positions. Different aspects of arc features are extracted by time-domain, frequency-domain, and wavelet packet energy analysis. A feature selection method based on random forest (RF) is adopted to determine the specific feature sets according to the reduction of Gini impurity. The integrated top ten features with a high correlation to the arc were selected for different combinations of loads and are input into the deep neural network (DNN) for calculating and training. Eventually, a comprehensive arc detection model with the function of detection and location determination for different load types is obtained. It proves that the proposed RF-DNN-based arc detection algorithm can identify and protect the series arc faults in multi-load scenarios efficiently and accurately to meet the practical needs.

29 November 2019 in High Voltage
Verified
Journal Article
Open access
HZHong‐Yang Zhou
Hong‐Yang Zhou
GMGuo‐Ming Ma
Guo‐Ming Ma
YWYuan Wang
Yuan Wang
WQWei‐Qi Qin
Wei‐Qi Qin
JJJun Jiang
Jun Jiang
CLCheng‐Rong Li
Cheng‐Rong Li
Health monitoring of gas insulated apparatus is critical to improve the reliability and to reduce the life cycle cost. Among the various methods for monitoring, optical sensing developed fast in recent years due to their highly sensitive and anti‐electromagnetic interference behaviour. This study reviews the optical monitoring methods for partial discharge, gas concentration and temperature of gas insulted apparatus. In addition, the challenges of sensor development are carefully discussed here. The future prospects of optical monitoring of gas insulated apparatus are also analysed to inspire new ideas.

1 January 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JJJun Jiang
Jun Jiang
MZMingxin Zhao
Mingxin Zhao
GMGuo-Ming Ma
Guo-Ming Ma
HSHong-Tu Song
Hong-Tu Song
CLCheng-Rong Li
Cheng-Rong Li
CZChaohai Zhang
Chaohai Zhang
Methane is one of the indicative gases in power transformer oil, and the detection of methane dissolved in oil with high accuracy is of great importance for dissolved gases analysis and fault diagnosis inside power transformers. Based on the Beer-Lambert spectral absorption law, dissolved methane detection with tunable diode laser absorption spectrum (TDLAS) is proposed in this paper for the advantages of high sensitivity and resolution. On the basis of wavelength modulation spectroscopy, a specialized TDLAS system was established. To meet the actual needs of field testing, the anti-vibration design of an integrated Herriott cell and a gas pressure (P)/temperature (T) setting are worked out. Photodetector, collimator, and Herriott cell are integrated into one component to reduce the effects of vibration. It is investigated that the temperature has little effect on the second harmonic amplitude in the range of 30 °C ~ 50 °C, and the vacuum pressure is reasonably set at about 1 kPa. Experimental results showed that the resolution of sensitivity could be reached as 6.8 mV/(μL/L), the maximum deviation was less than ±4 μL/L, and the response time is less than 5 min. In the end, field application was also carried out, proving it is a prospective online sensing technique to serve oil-immersed power transformers better.

23 January 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Open access
JJJun Jiang
Jun Jiang
ZWZhuowei Wang
Zhuowei Wang
XHXiao Han
Xiao Han
CZChaohai Zhang
Chaohai Zhang
GMGuoming Ma
Guoming Ma
YLYingting Luo
Yingting Luo
Online dissolved gas analysis (DGA) is an effective technique to obtain the health status information of insulation oil in power transformers. The typical hydrocarbon gases (methane, ethyne, ethene, ethane) decomposed from insulation oil, are the key indicators to diagnose the fault type and severity. To realize contactless and field measurement, a multi-gas detection system based on tunable diode laser absorption spectrum (TDLAS) is proposed in this paper. Critical technique problems on the light source, long path gas cell, and the topology for multi-gas detection are investigated. Individual central wavelengths of hydrocarbon gases are set at as 1653.72 nm for methane, 1530.37 nm for ethyne, 1620.04 nm for ethene and 1679.06 nm for ethane in the near infrared band. A 10.13 m long multi-pass gas cell is developed with the advantage of anti-vibration design. To share the optical absorption path, an optical switch is adopted to merge the multi-gas detection system. The high sensitivity of the TDLAS multi-gas detection system was demonstrated in the laboratory calibrations, with ethyne detection reaching sub-parts per million level, and the other hydrocarbon gases achieving ppm level. Furthermore, the comparison detection in the real 220 kV power transformer gave evidence to the effective monitoring of DGA, proving it an alternative approach to online detection of multiple gases in power transformer oil.

15 March 2019 in IEEE Access
Verified
Journal Article
Open access
JJJun Jiang
Jun Jiang
ZWZhe Wen
Zhe Wen
MZMingxin Zhao
Mingxin Zhao
YBYifan Bie
Yifan Bie
CLChen Li
Chen Li
CZChaohai Zhang
Chaohai Zhang
The increasing household loads make series arc faults more complex, which are difficult to be detected by traditional circuit breakers and lead to the frequent occurrence of residential fire accidents. In this paper, a comprehensive approach of complex load recognition and series arc detection is proposed on the basis of principal component analysis and support vector machine (PCA-SVM) combination model. Several typical loads were selected and analyzed, especially nonlinear and complex loads like power electronics load and multi-state load. 3 time-domain parameters, maximum slip difference (MSD), zero current period (ZCP) and maximum Euclidean distance (MED), and 9 frequency-domain harmonics information are collected to complex waveforms. To decrease the computation cost and further to enhance the response velocity, all the time-domain and frequency-domain information were blended and dimensionally reduced to 3 parameters by principal component analysis (PCA). Prior to series arc detection, load recognition is trained and completed with the artificial intelligence (AI) algorithm. At last, the comprehensive model of load recognition and series arc detection is achieved based on support vector machine (SVM). The accuracy of load recognition and series arc detection reaches 99.1% and 99.3%, respectively, demonstrating the excellent performances of the intelligent approach to diagnose the series arcing activities in modern household applications.

1 December 2015 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
GMGuo-Ming Ma
Guo-Ming Ma
HZHong-Yang Zhou
Hong-Yang Zhou
CLCheng-Rong Li
Cheng-Rong Li
JJJun Jiang
Jun Jiang
XCXue-Wei Chen
Xue-Wei Chen
The problem of surface charge accumulation on gas-insulator interface is one of the critical factors for the development of DC Gas Insulated transmission Lines (GIL). In order to solve this problem, researchers have proposed a variety of mathematical models in which the volume conductivity of SF 6 was assumed to be constant for calculating the distribution of surface charge. However, the conductivity of SF 6 was inconstant, affected by electric field strength. In this paper, a gas model is developed, taking into account the generation, recombination and motion of charge carriers in SF 6 of DC-GIL. The surface charge density and the electric field distribution on the insulator surface under DC voltage were simulated. Afterwards, the electric conduction through the volume of the insulator was proved to be the dominating accumulation mechanism. In order to improve the insulation performance, the influence of practical insulator shape on the electric field distribution in DC-GIL was studied. Three different shapes of insulator which were disc insulator, conical insulator and obtuse conical insulator were introduced and compared. The simulation results indicate the obtuse conical insulator was the most suitable configuration for DC-GIL.