Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education (Department of Electrical Engineering, Shanghai Jiao Tong University) School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University
Mr. Xiangying Tang
Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education (Department of Electrical Engineering, Shanghai Jiao Tong University) School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University
The development of renewable energy represented by wind, photovoltaic and hydropower has increased the uncertainty of power systems. In order to ensure the flexible operation of power systems with a high proportion of renewable energy, it is necessary to establish a multi-scenario power system flexibility evaluation method. First, this study uses a modified k-means algorithm to cluster operating scenarios of renewable energy and load to obtain several typical scenarios. Then, flexibility evaluation indices are proposed from three perspectives, including supply and demand balance of the zone, power flow distribution of the zone and transmission capacity between zones. Next, to calculate the flexibility evaluation indices of each scenario—and according to the occurrence probability of each scenario—we multiplied the indices of each scenario by the scenario occurrence probability to obtain comprehensive evaluation indices of all scenarios. Based on the actual historical output data of renewable energy and load of a southern power system in China, a flexibility evaluation was performed on the modified IEEE 14 system and modified IEEE 39 system. The results show that the proposed clustering method and flexibility indices can effectively reflect the flexibility status of the power system.
In the distribution network, renewable energy generation is increasing now, and the volatility and uncertainty of its output increase the demand for flexibility. This paper proposes the grid flexibility index, and establishes a multiobjective optimal configuration model of energy storage system considering flexibility and economy to improve the flexibility of the distribution network. Firstly, this paper analyzes the traditional flexibility index of supply and demand. On this basis, the grid flexibility index is proposed. Then, an optimal configuration model of energy storage system is proposed by minimizing the flexibility index and minimizing the cost of energy storage system. Finally, the multi-objective model is solved by NSGA-II algorithm, and IEEE 14 bus system is taken as an example to prove the effectiveness of the flexibility index and the configuration model. The results show that the proposed index can reflect the flexibility status of distribution network and the configuration model can improve the flexible operation capability of distribution network.