A prospective study was performed on 217 patients who received MIOM during corrective surgery of spinal deformities between March 2000 and December 2005. Aim is to determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve root function during corrective spine surgery. MIOM is becoming an increasingly used method of monitoring function during corrective spine surgery. The combination of monitoring of ascending and descending pathways may provide more sensitive and specific results giving immediate feedback information regarding any neurological deficits during the operation. Intraoperative somatosensory spinal and cerebral evoked potentials combined with continuous EMG and motor evoked potentials of the spinal cord and muscles were evaluated and compared with postoperative clinical neurological changes. A total of 217 consecutive patients with spinal deformities of different aetiologies were monitored by means of MIOM during the surgical procedure. Out of which 201 patients presented true negative findings while one patient presented false negative and three patients presented false positive findings. Twelve patients presented true positive findings where neurological deficit after the operation was predicted. All neurological deficits in those 12 patients recovered completely. The sensitivity of MIOM applied during surgery of spinal deformities has been calculated of 92.3% and the specificity 98.5%. Based upon the results of this study MIOM is an effective method of monitoring the spinal cord and nerve root function during corrective surgery of spinal deformities and consequently improves postoperative results. The Wake-up test for surgical procedure of spinal deformities became obsolete in our institution.
A prospective study of 36 patients who received multimodal intraoperative monitoring (MIOM) during decompression of thoracic spinal stenosis between March 2000 and December 2005 was chosen as the study design. The objective was to determine the sensitivity and specificity of MIOM techniques used for monitoring spinal cord during surgical thoracic decompression. The background data revealed that the surgical decompression for thoracic spinal stenosis is less frequent than in other regions of the spine. However, due to the relative narrow spinal canal, neurological complications could be severe. The combination of monitoring ascending and descending pathways may provide an early alert to the surgeon in order to alter the surgical procedure, and avoid neurological complications. The methods involved evaluation of intraoperative somatosensory spinal and cerebral evoked potentials and motor evoked potentials of the spinal cord and muscles that were compared with post operative clinical neurological changes. 36 consecutive patients with thoracic spinal stenosis of different aetiologies were monitored by the means of MIOM during the surgical procedure. 31 patients had true negative while one patient had false positive findings. Three patients had true positive and one patient had false negative findings. This indicates a sensitivity of 75% and a specificity of 97%. The one case of false negative findings recovered completely within 3 months. In conclusion, the MIOM is an effective method of monitoring the spinal cord during surgical decompression of the thoracic spine.
Although reverse shoulder arthroplasty (RSA) has shown successful postoperative outcomes, little is known about compensatory activation patterns of remaining shoulder muscles following RSA. The purpose of this experimental case control series was to investigate shoulder muscle strength and neuromuscular activation of deltoid and teres minor muscles 2 years after RSA. Humerus lengthening, center-of-rotation medialization, maximal voluntary strength, and electromyographic (EMG) activity were compared between the operated and the non-operated side of 13 patients (mean age: 73 years). Shoulder muscle strength was significantly lower on the operated side for external rotation (−54%), internal rotation (−20%), and adduction (−13%). Agonist deltoid EMG activity was lower on the operated side for shoulder flexion, extension, and internal and external rotation (p < 0.05). Antagonist deltoid coactivation was higher on the operated side for external rotation (p < 0.001). Large correlation coefficients were observed between shoulder adductor strength asymmetry and both center-of-rotation medialization (r = −0.73) and humerus lengthening (r = 0.71). Shoulder abduction strength and neuromuscular activation were well preserved 2 years after RSA, while persistent strength and activation deficits were observed for shoulder adduction and internal and external rotation. Additional studies are required to elucidate shoulder neuromuscular activation patterns before and after RSA to support decision making for surgical, implant design, and rehabilitation choices.