Benjamin Roach

Dr. Benjamin Roach

Oak Ridge National Laboratory
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2011 in Inorganic Chemistry
Verified
Journal Article
Closed access
RFRoss Forgan
Ross Forgan
BRBenjamin Roach
Benjamin Roach
PWPeter A. Wood
Peter A. Wood
FWFraser J. White
Fraser J. White
JCJohn Campbell
John Campbell
PTPeter Anthony Tasker
Peter Anthony Tasker

8 January 2020 in Minerals
Verified
Journal Article
Open access
PDF file
VBVeronica Bradley
Veronica Bradley
BMBenjamin Manard
Benjamin Manard
BRBenjamin Roach
Benjamin Roach
SMShalina C. Metzger
Shalina C. Metzger
KRKayron T. Rogers
Kayron T. Rogers
CHCole Hexel
Cole Hexel
The determination of trace elements, particularly rare earth elements, in uranium ore concentrates (UOCs) is important as the pattern can be indictive ore characteristics. Presented here is a methodology for accurately quantifying rare earth elements (REE) in UOCs. To improve the measurement uncertainty, isotope dilution mass spectrometry (IDMS) was utilized over other quantification techniques such as external calibration or standard addition. The isotopic determinations were measured by inductively coupled plasma-mass spectrometry (ICP-MS). To obtain high-fidelity isotopic measurements, separation of the REE from the uranium matrix was achieved by high-performance ion chromatography (HPIC), reducing the isobaric interferences. After separation, the target analytes were analyzed in two different modalities. For high precision analysis, the separated analytes were collected and measured by ICP-MS in an “offline” fashion. For a rapid approach, the separated analytes were sent directly into an ICP-MS for “online” analysis. These methods have been demonstrated to accurately quantify the REE content in a well-characterized UOC sample.

18 May 2012 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
RCRadu Custelcean
Radu Custelcean
PBPeter V. Bonnesen
Peter V. Bonnesen
BRBenjamin Roach
Benjamin Roach
NDNathan C. Duncan
Nathan C. Duncan
NiSO4 and FeSO4 self-assemble with heteroditopic ligands (L) comprising 2,2′-bipyridine and o-phenylene-(bis)urea cation- and anion-binding sites, respectively, into [ML3SO4] (M = Ni2+, Fe2+) triple-stranded ion-pair helicates and mesocates.

1 February 2019 in Journal of Chromatography A
Verified
Journal Article
Closed access
BRBenjamin Roach
Benjamin Roach
EFEmilie K. Fenske
Emilie K. Fenske
RIRalph H. Ilgner
Ralph H. Ilgner
CHCole R. Hexel
Cole R. Hexel
THTamara J. Haverlock
Tamara J. Haverlock
JGJoseph M. Giaquinto
Joseph M. Giaquinto

10 September 2021 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
BMBenjamin Manard
Benjamin Manard
SMShalina C. Metzger
Shalina C. Metzger
KRKayron T. Rogers
Kayron T. Rogers
BTBrian W. Ticknor
Brian W. Ticknor
NZNasser Zirakparvar
Nasser Zirakparvar
CHCole Hexel
Cole Hexel
This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm2), and delivers solvent (2% HNO3) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition (240Pu/239Pu and 242Pu/239Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240Pu/239Pu ratio on all three CRMs and <10% for the 242Pu/239Pu ratio on CRM 136 and 138. The percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240Pu/239Pu and <15% for the 242Pu/239Pu. Method limits of detection were determined, based on measurements of an enriched 244Pu material, to be ∼7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

7 February 2019 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
EFEmilie K. Fenske
Emilie K. Fenske
BRBenjamin Roach
Benjamin Roach
DGDavid C. Glasgow
David C. Glasgow
RIRalph H. Ilgner
Ralph H. Ilgner
JGJoseph M. Giaquinto
Joseph M. Giaquinto