Artificial vessels capable of long-term patency are essential clinical tools in vascular surgery that involves small vessels. On-going attempts to develop artificial vessels that complements restenosis have not been entirely successful. Here, we report on the fabrication of small-sized artificial vessels using a three-dimensional bio-printer. The fabrication employed biodegradable polycaprolactone and autologous MSCs harvested from the bone-marrow of canines. The MSCs were cultured and differentiated into endothelial-like cells. After confirming differentiation, artificial vessels comprising three-layers were constructed and implanted into the arteries of canines. The autologous MSCs printed on artificial vessels (cell-derived group) maintained a 64.3% patency (9 of 14 grafts) compared with artificial vessels without cells (control group, 54.5% patency (6 of 11 grafts)). The cell-derived vessels (61.9 cells/mm2 ± 14.3) had more endothelial cells on their inner surfaces than the control vessels (21 cells/mm2 ± 11.3). Moreover, the control vessels showed acute inflammation on the porous structures of the implanted artificial vessels, whereas the cell-derived vessels exhibited fibrinous clots with little to no inflammation. We concluded that the minimal rejection of these artificial vessels by the immune system was due to the use of autologous MSCs. We anticipate that this study will be of value in the field of tissue-engineering in clinical practice.
Restenosis at a vascular anastomosis site is a major cause of graft failure and is difficult to prevent by conventional treatment. Perivascular drug delivery has advantages as drugs can be diffused to tunica media and subintima while minimizing the direct effect on endothelium. This in vivo study investigated the comparative effectiveness of paclitaxel, sirolimus, and sunitinib using a perivascular biodegradable microneedle cuff. A total of 31 New Zealand white rabbits were used. Rhodamine was used to visualize drug distribution (n = 3). Sirolimus- (n = 7), sunitinib- (n = 7), and paclitaxel-loaded (n = 7) microneedle cuffs were placed at balloon-injured abdominal aortae and compared to drug-free cuffs (n = 7). Basic histological structures were not affected by microneedle devices, and vascular wall thickness of the device-only group was similar to that of normal artery. Quantitative analysis revealed significantly decreased neointima formation in all drug-treated groups (p < 0.001). However, the tunica media layer of the paclitaxel-treated group was significantly thinner than that of other groups and also showed the highest apoptotic ratio (p < 0.001). Proliferating cell nuclear antigen (PCNA)-positive cells were significantly reduced in all drug-treated groups. Sirolimus or sunitinib appeared to be more appropriate for microneedle devices capable of slow drug release because vascular wall thickness was minimally affected.
We investigated the role of a sirolimus-embedded silk microneedle (MN) wrap as an external vascular device for drug delivery efficacy, inhibition of neointimal hyperplasia, and vascular remodeling. Using dogs, a vein graft model was developed to interpose the carotid or femoral artery with the jugular or femoral vein. The control group contained four dogs with only interposed grafts; the intervention group contained four dogs with vein grafts in which sirolimus-embedded silk-MN wraps were applied. After 12-weeks post-implantation, 15 vein grafts in each group were explanted and analyzed. Vein grafts applied with the rhodamine B–embedded silk-MN wrap showed far higher fluorescent signals than those without the wrap. The diameter of vein grafts in the intervention group decreased or remained stable without dilatation; however, it increased in the control group. The intervention group had femoral vein grafts with a significantly lower mean neointima-to-media ratio, and had vein grafts with an intima layer showing a significantly lower collagen density ratio than the control group. In conclusion, sirolimus-embedded silk-MN wrap in a vein graft model successfully delivered the drug to the intimal layer of the vein grafts. It prevented vein graft dilatation, avoiding shear stress and decreasing wall tension, and it inhibited neointimal hyperplasia.