The combination of laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) was investigated to improve the limit of detection (LoD) of trace elements in liquid water, while preserving the distinctive on-line monitoring capabilities of LIBS analysis. The influence of the main experimental parameters, namely the ablation fluence, the excitation fluence, and the inter-pulse delay was studied to maximize the fluorescence signal. The plasma was produced by a 266 nm frequency-quadrupled Q-switched Nd:YAG laser and the trace elements under investigation were then re-excited by a nanosecond optical parametric oscillator (OPO) laser, delivering pulses in the sub-mJ energy range, and tuned to strong absorption lines of the trace elements. The reproducibility of the measurements was improved using a home-made flow-cell, and relative standard deviations as low as 6.7% for a series of 100 shots were attained with a repetition rate of 0.7 Hz. Using the LIBS-LIF technique, we demonstrated LoDs of 39 ppb and 65 ppb for Pb and Fe, respectively, accumulating over 100 laser shots only, which correspond to an improvement of about 500 times with respect to LIBS.
8 December 2011 in Journal of Analytical Atomic Spectrometry
Double-pulse laser-induced breakdown spectroscopy (DP-LIBS) was performed for quantitative analysis of three metallic trace elements: Fe, Pb and Au in aqueous solutions. The plasma was generated using a UV (266 nm) frequency-quadrupled Q-switched Nd:YAG laser (7 ns) and then reheated by a 1064 nm Q-switched Nd:YAG laser (7 ns) in a quasi-collinear geometrical configuration. In order to improve the reproducibility of LIBS measurements, a circulation cell was used, providing a reproducibility of about 4% with a laser repetition rate of 0.3 Hz. The influence of the inter-pulse delay and the fluence of the second laser pulse on the signal-to-noise ratio (SNR) for the analytical lines was investigated and optimized. Analytical figures of merit of DP-LIBS and conventional single-pulse LIBS (SP-LIBS) were evaluated by establishing the calibration curves for the Fe I 358.12 nm, Pb I 405.78 nm and Au I 267.60 nm lines. The signal was greatly enhanced in DP-LIBS while the noise level did not vary as much. An improvement of the relative limit of detection of about 10 was achieved using DP-LIBS when compared to UV SP-LIBS in all cases. Measurement of the electron density as a function of time indicates that the plasma plume lifetime is longer in DP-LIBS. Similar trends in the excitation temperature were not observed for reasons that we attribute to larger uncertainties related to the Boltzmann plot method.
1 December 2018 in Spectrochimica Acta Part B: Atomic Spectroscopy
Geochemical and mineralogical characterization studies play an important role in the definition of mineral deposits. Each mineral system has a unique set of minerals with different chemical makeup and physical properties. Platinum-group elements (PGEs), for example, are scarce resources with many applications. The optimization of extraction process efficiency is therefore crucial to prevent resource shortage and increased bulk prices. To improve the mineral liberation process, high throughput sensors must be added alongside the production line as part of fast process analysis implementation. Current analytical methods are either ineffective to assess PGE content, or unusable in the conditions of the processing facilities. This article shows how Laser-induced breakdown spectroscopy (LIBS) technology, developed by ELEMISSION Inc, can circumvent these drawbacks by enabling automated, ultra-fast, and precise quantitative mineral analyses in any working environment. The drill core samples that were used in this study were collected at the Stillwater platinum group element mine in the United States. The data used for the mineralogical database was validated using the TESCAN Integrated Mineral Analyzer (TIMA) instrument.