Due to rapid expansions of renewable energy (RE) generations, it becomes more important to assess the feasibility of power system operation under limited controllable resources. Especially, exact evaluation of the system reserve for preserving system security is required under erroneous RE output predictions. This paper proposes a method to evaluate the size of the feasible region of power system operation in control space for the examination of the effective system reserve margin under uncertainties. Predicted RE and demands with their confidence intervals (CIs) are specified to formulate a problem for the evaluation of the size of the worst case feasible region, where positive size implies feasibility, while negative, infeasibility. The method computes the degree of system security, which is referred to as “Robust Power System Security” in this paper. The problem is formulated as bi-level optimization, which is linearized and transformed into the mixed integer linear programming (MILP) problem. This is a new approach in the treatment of uncertainties. We use DC power flow and linear constrained dynamic economic dispatch problem to demonstrate the effectiveness of the proposed method. The proposed approach is useful in power system planning in analyzing the feasibility of dynamic real-time operation in future circumstance.
The future grid will include a high penetration of distributed generation, which will have an impact on its security. This paper discusses the latest trends, components, tools, and frameworks aimed at 100% renewable energy generation for the emerging grid. The technical and economic impacts of renewable energy sources (RES)-based distributed generation (DG) on the emerging grid security are also discussed. Moreover, the latest approaches and techniques for allocating RES-DG into the distribution networks using specific performance indices based on recent literature were reviewed. Most of the methods in recent literature are based on metaheuristic optimization algorithms that can optimally allocate the RES-DGs based on the identified network variables. However, there is a need to extend these methods in terms of parameters considered, objectives, and possible ancillary support to the upstream network. The limitations of existing methods in recent literature aimed at ensuring the security of the integrated transmission-active distribution network under high RES-DG penetration were identified. Lastly, the existing coordination methods for voltage and frequency control at the transmission and active distribution system interface were also investigated. Relevant future research areas with a focus on ensuring the security of the emerging grid with high RES-DG penetration into the distribution networks are also recommended.
Maintaining satisfactory operating of power system requires optimal tuning of controller such as automatic voltage regulator (AVR) and power system stabilizer (PSS) parameters.
1 December 2021 in Sustainable Energy, Grids and Networks
The increase in energy needs to support sustainable development will trigger a large additional power supply. Unfortunately, a current energy source is mostly produced by fossil fuels. This condition can affect the increase of global warming and climate change. Nowadays, many countries including Indonesia are aware of the effect of the use of fossil fuels on environmental devastation. Therefore, the use of clean energy gets more attention from many countries since its energy source is unlimited and harvested from nature. One of the clean energy sources that are widely utilized over the world is photovoltaic (PV). PV is an appropriate clean energy technology to be utilized in Indonesia since this country lies on the equator line and gets solar irradiance over the year. This paper proposed the design of PV systems for a public-school building. These PV schemes proposed in this study are classified into off-grid, on-grid, and hybrid PV systems. From the simulation results, it is shown that the hybrid PV system with energy supplied by PT. PLN (State Electricity Company) results in the highest saving annual cost and provides an environmentally friendly energy source for public-school buildings.