Laurence Clift

Mr. Laurence Clift


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2016 in Technology and Disability
Verified
Journal Article
Open access
PDF file
TMTulio MAXIMO
Tulio MAXIMO
LCLaurence Clift
Laurence Clift
BACKGROUND: Recently in Brazil, there has been investment and improvements in the service delivery system for assistive technology provision. However, there is little documentation of this process, or evidence that users are being involved appropriat

1 September 2002 in Injury Control and Safety Promotion
Verified
Journal Article
Closed access
LCLaurence Clift
Laurence Clift
TNT.B. Navarro
T.B. Navarro
DTD.A.B. Thomas
D.A.B. Thomas
Stepladder accidents continue to be a major cause of injury at home and at work. Despite this, few changes have been seen in their design or their labelling. Many of the accidents occurring appear to be whilst the stepladder is being utilised in a manner which the user considers reasonable, but the manufacturer considers abuse. This work, sponsored by the Health and Safety Executive, investigates whether this mismatch can be eliminated in order to improve safety. The research combines user profiling with dynamic trials to establish what behaviour stepladders need to sustain. Through innovative measuring techniques, the demands on the stepladder system are quantified and the margin of safety calculated. Extensive dynamic trials generated data for over 4000 user, stepladder and task combinations. Individuals were given demanding tasks, but permitted to undertake them in a manner they considered reasonable and the resulting data can be considered as representative of the demands they would place on stepladders in everyday use. From this data, the stepladder and user system has been modelled, allowing manipulation of the stepladder parameters such that a virtual stepladder can be created which provides sufficient stability to tolerate all reasonably foreseeable use. In addition this model is used to generate predictive software which can determine the level of safety provided by real, or theoretical, stepladders. In conclusion, a specification for a simple test is given which could be routinely conducted to determine whether any given stepladder will offer the minimum level of stability considered necessary for safe use.

25 March 2013 in Ergonomics
Verified
Journal Article
Open access
EEEddy Elton
Eddy Elton
DJDaniel Johnson
Daniel Johnson
CNColette Nicolle
Colette Nicolle
LCLaurence Clift
Laurence Clift
Current older adult capability data-sets fail to account for the effects of everyday environmental conditions on capability. This article details a study that investigates the effects of everyday ambient illumination conditions (overcast, 6000 lx; in-house lighting, 150 lx and street lighting, 7.5 lx) and contrast (90%, 70%, 50% and 30%) on the near visual acuity (VA) of older adults (n = 38, 65–87 years). VA was measured at a 1-m viewing distance using logarithm of minimum angle of resolution (LogMAR) acuity charts. Results from the study showed that for all contrast levels tested, VA decreased by 0.2 log units between the overcast and street lighting conditions. On average, in overcast conditions, participants could detect detail around 1.6 times smaller on the LogMAR charts compared with street lighting. VA also significantly decreased when contrast was reduced from 70% to 50%, and from 50% to 30% in each of the ambient illumination conditions. Practitioner summary: This article presents an experimental study that investigates the impact of everyday ambient illumination levels and contrast on older adults' VA. Results show that both factors have a significant effect on their VA. Findings suggest that environmental conditions need to be accounted for in older adult capability data-sets/designs.


1 January 2003
Verified
Journal Article
Closed access
RWRuth Welsh
Ruth Welsh
Andrew MorrisAndrew Morris
Andrew Morris
LCLaurence Clift
Laurence Clift

1 September 2011 in Proceedings of the Human Factors and Ergonomics Society Annual Meeting
Verified
Journal Article
Closed access
PDF file
LCLaurence Clift
Laurence Clift
MCMaxine Clift
Maxine Clift
EEEdward Elton
Edward Elton
This paper discusses an appraisal of the fit of operating theatre tables to the surgical staff who have to use them. In total 55 tables were evaluated in 70 configurations. By identifying the ethnic profile of the surgical population, appropriate anthropometric data was obtained which provided a user-centred focus for the evaluation. Using basic dimensional data the range of adjustment of the height of each table was scrutinised to see if it was appropriate to accommodate the needs of the user in terms of reach for open and laparoscopic surgery as well as sight lines. It was found that the majority of tables failed to provide adequate adjustment to accommodate the needs of the users, with smaller users suffering the poorest fit. By converting the data comparison to a simple star rating scheme, a relatively complex ergonomic investigation could be made readily available to procurement professionals and help guide them into appropriate choices to enable them to secure best value in equipment selection and help prevent ongoing occupational ill health.