This paper proposes a 500 MS/s 4-bit flash analog-to-digital converter (ADC) featuring a differential input voltage range of 1.2 Vpp operating at a supply voltage of 1.2 V. Although the proposed circuit utilizes a conventional flash ADC structure, its track and hold circuit, driving buffer, and preamp circuits corresponding to the analog stages are designed using complementary architecture to attain a sufficient swing range even at a low supply voltage. Notably, the proposed structure satisfies the error requirements. The error source of the flash ADC, such as the comparator’s input referred offset, did not degrade its performance, while the use of a calibration circuit, characterized by power consumption and area burdens and increased complexity, could also be avoided. Therefore, the proposed flash ADC met the error requirements, such as the comparator’s input referred offset, without the need for calibration circuits. The chip, fabricated using the TSMC 65 nm process, covers an area of 1,160 × 950 μm2 and consumes 78 mW of power. Furthermore, its signal-to-noise and distortion ratio and spurious-free dynamic range were measured to be 23.36 dB and 30.26 dB, respectively, at a sampling frequency of 500 MHz.
24 February 2015 in Microwave and Optical Technology Letters
Body-contouring devices deliver controlled thermal energy to treat cellulite, reduce localized fat, and improve skin elasticity. Since the thermal effect is closely related to the delivered RF output power, precise control of the output power is critical for both efficacy and safety. In this study, we propose a 2.4 GHz CMOS pulse-mode transmitter for body-contouring device applications, featuring precise control of the average power delivered to the body. The transmitter comprises a fully integrated phase-locked loop (PLL) synthesizer, pulse modulator (PM), and 10 mW power amplifier (PA). It is fabricated in a 65 nm CMOS with a compact die area of 3.75 mm2. The PA provides four-level continuous-mode output control from −0.3 dBm to 11.1 dBm, and the PM performs programmable PA switching for pulse-mode operation of the PA with a wide range of pulse rates and duty ratios. By combining the continuous-mode output power control and pulse-mode on–off time regulation, the average output power delivered to the skin is finely controlled, managing the delivered power within a safe skin temperature below 65 °C. The PLL loop filter is fully integrated with a wide programmability, improving the form factor and bill of materials for the target devices. Measurement results confirm that the designed transmitter can accurately control both the average output power and pulse profile across the 2.4 GHz ISM band, demonstrating its suitability for compact home-use RF body-contouring devices.
4 December 2018 in Microwave and Optical Technology Letters
This paper presents a highly integrated radio frequency (RF) CMOS receiver module for monitoring the core body temperature thermometer, which operates in the dual band 1.35 and 2.75 GHz ranges. The RF receiver IC, such as a Dicke radiometer, includes the full receiver circuits, RF switch and modulator, and duty calibrating circuit using a 65 nm CMOS process. With the proposed duty cycle modulation, accurate temperature sensing is achievable even with a receiver gain mismatch and fluctuation. The measured temperature ranges from 22 to 47.3°C, and the measured voltage slope is 2.97 mV/ms·°C, and the temperature error is less than 0.9°C in 1.35 GHz band. The radiometric RF CMOS IC has a size of 1.6 × 2.3 mm 2 and the current consumption of 52 mW. Unlike the general skin temperature measurement of existing infrared (IR) sensors, the RF microwave core body thermometer equipped with an RF receiver IC that measures core body temperature inside a human body will be used in various fields as a digital healthcare and medical device.