Lassue Stephane

Prof. Lassue Stephane

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in Journal of Thermal Science
Verified
Journal Article
Closed access
PDF file
JSJibao Shen
Jibao Shen
LSLassue Stephane
Lassue Stephane
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
DHDezhong Huang
Dezhong Huang

29 December 2010 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
ZYZohir Younsi
Zohir Younsi
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
LSLassue Stephane
Lassue Stephane
DRDaniel R. Rousse
Daniel R. Rousse
AJAnnabelle Joulin
Annabelle Joulin

1 January 2002 in Energy and Buildings
Verified
Journal Article
Closed access
DDDidier Defer
Didier Defer
JSJ. Shen
J. Shen
LSLassue Stephane
Lassue Stephane
BDB. Duthoit
B. Duthoit

17 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
ELEnghok LEANG
Enghok LEANG
PTPierre Tittelein
Pierre Tittelein
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
LSLassue Stephane
Lassue Stephane
As the heating demands of buildings drop considerably, the use of solar walls makes increasing sense. One of the obstacles to the development of such walls is their need for on-site implementation by specialized companies. On the other hand, a storage wall is generally composed of heavy materials with high inertia, which prevents prefabrication of the solar component. To avoid this problem and allow for solar walls to be prefabricated in the factory, a novel approach to replacing this heavy wall with a lighter storage wall incorporating phase change materials (PCM) has been proposed. This paper aims to demonstrate the impact of PCM on the thermal energy performance once they have been integrated into the storage wall of the composite Trombe wall. Addressed herein will be the heat transfer exchange inside a house located in the northern part of France, where a composite Trombe wall has been fitted without PCM. Three configurations will be investigated—(1) the model house without the solar Trombe wall, defined as the reference configuration; (2) the model house integrating the concrete solar Trombe wall; and (3) the model house integrating the PCM solar Trombe wall. Two setpoint temperatures will be introduced—(a) a constant setpoint of 20 °C, and (b) a variable setpoint of 19 °C (14 h from 7:00 a.m. to 9:00 p.m.) and 16 °C (10 h from 9:00 p.m. to 7:00 a.m.). Furthermore, three different climate conditions will be adopted to run simulations—Paris-Orly, Lyon, and Nice. Dymola/Modelica, a dynamic thermal simulation tool, will be utilized to simulate the thermal performance of these defined configurations. The results obtained, regarding a solar Trombe wall installation that applies two distinct storage walls exposed to the weather of Paris, showed similar minimizations of the one-year energy heating demand inside the bedroom, equal to roughly 20% (i.e., 20.45% of concrete storage wall and 19.90% of PCM storage wall) compared to the reference configuration (i.e., the house with no solar Trombe wall). Based on the imposed setpoint temperature by means of night and day reductions, the resulting heating energy demand in the bedroom, through application of the two storage walls (concrete and PCM) and three different climatic regions could be minimized by 20.34% in Paris, 20.20% in Lyon, and 68.10% in Nice (for the concrete storage wall) vs. the reference configuration; and by 18.79% in Paris, 19.56% in Lyon, and 55.15% in Nice (for the PCM storage wall) vs. the reference configuration.

28 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
ELEnghok LEANG
Enghok LEANG
PTPierre Tittelein
Pierre Tittelein
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
LSLassue Stephane
Lassue Stephane
Thermal energy storage (TES), which features an innovative technology, can enhance energy efficiency in the building sector and reduce CO2 emissions. Due to their high heat storage capacity, phase change materials (PCMs) have impressed many researchers. This paper investigates the energy performance of an individual house integrating a solar Trombe wall containing PCM with respect to heating demand and thermal comfort applications. The thermal energy performance of the design house was simulated using Dymola/Modelica, the thermal building simulation tool, whereby the optimization of objective functions as regards heating demand and thermal comfort was executed using GenOpt, the generic optimization software. Optimization of the solar Trombe wall focuses on the feasibility to find the optimal PCM parameters when running GenOpt, which consist of latent heat, melting temperature, PCM thickness and thermal conductivity, in order to minimize both the annual energy consumption for heating and the number of hours of thermal discomfort. The parametric study was first conducted for each PCM parameter so as to not only observe its effect on the identified energy performance, but also ensure the absence of errors in simulation runs before performing the optimization. The ‘Coordinate Search’ Generalized Pattern Search (GPS) algorithm was applied to minimize the objective function, whereas the ‘Weighted Sum Approach’ was used to solve the multi-objective function problem. Results showed that the higher the latent heat, the lower the heating demand and the greater the thermal comfort. The results of these parametric studies show that for the effect of the parameter on heating, demand is quite limited (1–2 kWh·m−2·year−1) whereas the effect on thermal comfort is more significant. The optimal PCM melting temperature is higher for warmer climates; it is also higher for the studied case applying the optimization method to minimize the objective function by assigning the number of hours of thermal discomfort (from 32.8 ∘C to 35.9 ∘C, depending on weather) than it is when applying the optimization method to reduce the objective function by assigning heating demand (from 31.5 ∘C to 32.9 ∘C, again depending on weather).

14 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RIRima Abou Ibrahim
Rima Abou Ibrahim
PTPierre Tittelein
Pierre Tittelein
LSLassue Stephane
Lassue Stephane
Fadi Hage ChehadeFadi Hage Chehade
Fadi Hage Chehade
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
Façades built with integrated passive solar systems hold great promise for improving the energy performance of buildings and achieving indoor comfort conditions. Among these techniques, solar air preheating systems with different configurations have proven their ability to reduce the energy consumption of buildings during the heating season. In this study, we propose a ventilated solar wall (VSW) with a thermal storage unit intended for preheating ventilation air. The final aim of this study is to determine the thermal performance of the studied VSW over a significant time period (during the heating season) under various climatic conditions when it is integrated into the building envelope. Therefore, for this purpose, a simplified model was developed to be coupled to a building energy simulation (BES) code. The results from the detailed steady-state 2D computational fluid dynamics (CFD) model show that the thermal efficiency of the VSW ranged from 55% to 70% as the air mass flow rate increased from 0.008 kg/s to 0.02 kg/s for a surface of 2.15 m2. These results were used to evaluate the convective heat transfer coefficients in the two air cavities and to validate the simplified model. The results indicate good agreement between the two models.