Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Most commercially available cochlear implants and hearing aids use microphones as sensors for capturing the external sound field. These microphones are in general located in an external element, which is also responsible for processing the sound signal. However, the presence of the external element is the cause of several problems such as discomfort, impossibility of being used during physical activities and sleeping, and social stigma. These limitations have driven studies with the goal of developing totally implantable hearing devices, and the design of an implantable sensor has been one of the main challenges to be overcome. Different designs of implantable sensors can be found in the literature and in some commercial implantable hearing aids, including different transduction mechanisms (capacitive, piezoelectric, electromagnetic, etc), configurations microphones, accelerometers, force sensor, etc) and locations (subcutaneous or middle ear). In this work, a detailed technical review of such designs is presented and a general classification is proposed. The technical characteristics of each sensors are presented and discussed in view of the main requirements for an implantable sensor for hearing devices, including sensitivity, internal noise, frequency bandwidth and energy consumption. The feasibility of implantation of each sensor is also evaluated and compared.
Metamaterial absorbers with nearly 100% absorption in the terahertz (THz) spectral band have been designed and fabricated using a periodic array of aluminum (Al) squares and an Al ground plane separated by a thin silicon dioxide (SiO2) dielectric film. The entire structure is less than 1.6 mm thick making it suitable for the fabrication of microbolometers or bi-material sensors for THz imaging. Films with different dielectric layer thicknesses exhibited resonant absorption at 4.1, 4.2, and 4.5 THz with strengths of 98%, 95%, and 88%, respectively. The measured absorption spectra are in good agreement with simulations using finite element modeling.
In this article we report on metamaterial-based narrowband thermal terahertz (THz) emitters with a bandwidth of about 1 THz. Single band emitters designed to radiate in the 4 to 8 THz range were found to emit as high as 36 W/m2 when operated at 400 °C. Emission into two well-separated THz bands was also demonstrated by using metamaterial structures featuring more complex unit cells. Imaging of heated emitters using a microbolometer camera fitted with THz optics clearly showed the expected higher emissivity from the metamaterial structure compared to low-emissivity of the surrounding aluminum.
A narrowband MEMS direction finding sensor has been developed based on the mechanically coupled ears of theOrmia Ochraceafly. The sensor consists of two wings coupled at the middle and attached to a substrate using two legs. The sensor operates at its bending resonance frequency and has cosine directional characteristics similar to that of a pressure gradient microphone. Thus, the directional response of the sensor is symmetric about the normal axis making the determination of the direction ambiguous. To overcome this shortcoming two sensors were assembled with a canted angle similar to that employed in radar bearing locators. The outputs of two sensors were processed together allowing direction finding with no requirement of knowing the incident sound pressure level. At the bending resonant frequency of the sensors (1.69 kHz) an output voltage of about 25 V/Pa was measured. The angle uncertainty of the bearing of sound ranged from less than 0.3° close to the normal axis (0°) to 3.4° at the limits of coverage (±60°) based on the 30° canted angle used. These findings indicate the great potential to use dual MEMS direction finding sensor assemblies to locate sound sources with high accuracy.
A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8 THz and 4.75 THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.