Richard Fair

Prof. Richard Fair

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2004 in Analytica Chimica Acta
Verified
Journal Article
Closed access
VSVijay Srinivasan
Vijay Srinivasan
VPVamsee K Pamula
Vamsee K Pamula
RFRichard Fair
Richard Fair

27 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SHShuquan Huang
Shuquan Huang
JCJessica Connolly
Jessica Connolly
Andrey KhlystovAndrey Khlystov
Andrey Khlystov
RFRichard Fair
Richard Fair
A prototype aerosol detection system is presented that is designed to accurately and quickly measure the concentration of selected inorganic ions in the atmosphere. The aerosol detection system combines digital microfluidics technology, aerosol impaction and chemical detection integrated on the same chip. Target compounds are the major inorganic aerosol constituents: sulfate, nitrate and ammonium. The digital microfluidic system consists of top and bottom plates that sandwich a fluid layer. Nozzles for an inertial impactor are built into the top plate according to known, scaling principles. The deposited air particles are densely concentrated in well-defined deposits on the bottom plate containing droplet actuation electrodes of the chip in fixed areas. The aerosol collection efficiency for particles larger than 100 nm in diameter was higher than 95%. After a collection phase, deposits are dissolved into a scanning droplet. Due to a sub-microliter droplet size, the obtained extract is highly concentrated. Droplets then pass through an air/oil interface on chip for colorimetric analysis by spectrophotometry using optical fibers placed between the two plates of the chip. To create a standard curve for each analyte, six different concentrations of liquid standards were chosen for each assay and dispensed from on-chip reservoirs. The droplet mixing was completed in a few seconds and the final droplet was transported to the detection position as soon as the mixing was finished. Limits of detection (LOD) in the final droplet were determined to be 11 ppm for sulfate and 0.26 ppm for ammonium. For nitrate, it was impossible to get stable measurements. The LOD of the on-chip measurements for sulfate was close to that obtained by an off-chip method using a Tecan spectrometer. LOD of the on-chip method for ammonium was about five times larger than what was obtained with the off-chip method. For the current impactor collection air flow (1 L/min) and 1 h collection time, the converted LODs in air were: 0.275 μg/m3 for sulfate, 6.5 ng/m3 for ammonium, sufficient for most ambient air monitoring applications.

15 January 2024 in ACM Transactions on Design Automation of Electronic Systems
Verified
Journal Article
Open access
TLTung-Che Liang
Tung-Che Liang
YCYi-Chen Chang
Yi-Chen Chang
ZZZhanwei Zhong
Zhanwei Zhong
YBYaas Bigdeli
Yaas Bigdeli
THTsung-Yi Ho
Tsung-Yi Ho
RFRichard Fair
Richard Fair
We describe an exciting new application domain for deep reinforcement learning (RL): droplet routing on digital microfluidic biochips (DMFBs). A DMFB consists of a two-dimensional electrode array, and it manipulates droplets of liquid to automatically execute biochemical protocols for clinical chemistry. However, a major problem with DMFBs is that electrodes can degrade over time. The transportation of droplet transportation over these degraded electrodes can fail, thereby adversely impacting the integrity of the bioassay outcome. We demonstrated that the formulation of droplet transportation as an RL problem enables the training of deep neural network policies that can adapt to the underlying health conditions of electrodes and ensure reliable fluidic operations. We describe an RL-based droplet routing solution that can be used for various sizes of DMFBs. We highlight the reliable execution of an epigenetic bioassay with the RL droplet router on a fabricated DMFB. We show that the use of the RL approach on a simple micro-computer (Raspberry Pi 4) leads to acceptable performance for time-critical bioassays. We present a simulation environment based on the OpenAI Gym Interface for RL-guided droplet routing problems on DMFBs. We present results on our study of electrode degradation using fabricated DMFBs. The study supports the degradation model used in the simulator.

1 May 1991 in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
Verified
Journal Article
Closed access
RFRichard Fair
Richard Fair
CGCarl L. Gardner
Carl L. Gardner
MJM.J. Johnson
M.J. Johnson
SKS.W. Kenkel
S.W. Kenkel
DRD.J. Rose
D.J. Rose
RSR. Subrahmanyan
R. Subrahmanyan
Two-dimensional (2-D) effects are becoming increasingly important in the diffusion of impurities in submicrometer silicon devices. The authors describe a 2-D process simulator, PREDICT2, that handles implant damage effects, annealing, and lateral diffusion. PREDICT2 simulates the diffusion of impurities in silicon by using phenomenological diffusion coefficients. The phenomenological models are verified by comparing simulated and experimental results. This approach is compared with that of point-defect-based simulators. The experimental technique for measuring impurity profiles in two dimensions is outlined. The method for generating diffusion models is illustrated by examining 2-D phosphorous diffusion. Numerical simulations and experimental measurements are compared. The numerical methods used in the simulator are described, and directions for future work are suggested

1 May 1990 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
RSRavi Subrahmanyan
Ravi Subrahmanyan
HMHisham Z. Massoud
Hisham Z. Massoud
RFRichard Fair
Richard Fair
The two‐dimensional diffusion of phosphorus has been studied by comparing profiles measured experimentally after furnace and rapid thermal annealing with simulated profiles obtained with the two‐dimensional simulators SUPREM IV and PREDICT 2. It was first shown experimentally that the effect of stress due to the window edge on chemical staining used in the measurement process is not significant to within the experimental error. It was then observed that there is considerable disagreement between measured and simulated profiles in the lateral direction, especially in the region directly under the mask edge. Possible explanations for the differences are discussed in terms of the inaccuracy of the initial implant simulation, the absence of damage annealing modeling in the simulation, and the effect of stress in the window edge vicinity on diffusion. When vacancy generation resulting from the reaction of the oxide with the underlying silicon substrate was included in the simulations, better agreement was observed with the experimental profiles.

22 July 1997
Verified
Conference Paper
Closed access
PDF file
RFRichard Fair
Richard Fair
VPVamsee K Pamula
Vamsee K Pamula
MPMichael G Pollack
Michael G Pollack
We report on a new methodology for chemical detection of explosive particles associated with anti-personnel mines. Trace particle detection can be used to complement vapor detection of explosives with an electronic noise. Our approach is to remotely stimulate a target area with a high intensity, focused air ultrasonic beam whose energy can megasonically clean the target area of particles above a designed for size. We have designed a MEMS electrostatic transducer to test the concept. Nanogram particle detection will occur by collecting particles on an array of temperature sensitive MEMS sensors and irradiating the particles with 3-5 micrometers wavelength IR light. Explosive particles will selectively absorb the IR energy at approximately 1600 cm-1, decompose, and give off heat which can be detected.