We compared the clinical course of rotator cuff tears between rotator cuff exercise and bone marrow aspirate concentration (BMAC)-platelet rich plasma (PRP) injection to identify the therapeutic effects of BMAC-PRP on partial tear of the rotator cuff tendon. Twenty-four patients with partial tear of the rotator cuff tendon participated in this study. Twelve patients underwent extraction of BMACs and PRP and received the injection of BMAC-PRP at the tear site under ultrasound guidance. Twelve patients in the control group were asked to perform the rotator cuff exercise for 3 months. Visual analog scale (VAS) and manual muscle test (MMT) scores of the supraspinatus muscle were measured, and the American Shoulder and Elbow Surgeons (ASES) score was recorded before, 3 weeks, and 3 months after injection. Tear size was measured by the greatest longitudinal tear length. The change in the VAS differed between groups at 3 months (P = 0.039) but not at 3 weeks (P = 0.147). The ASES scores in the BMAC-PRP group changed from 39.4 ± 13.0 to 54.5 ± 11.5 at 3 weeks and 74.1 ± 8.5 at 3 months while those in the control group changed from 45.9 ± 12.4 to 56.3 ± 12.3 at 3 weeks (P = 0.712) and 62.2 ± 12.2 at 3 months (P = 0.011). The tear size decreased at 3 weeks or 3 months after the BMAC-PRP injection but was not significantly different from that in the control group. BMAC-PRP improved pain and shoulder function in patients with partial tear of the rotator cuff tendon. The patients were registered in the institutional board registry of Samsung Medical Center (registry number 2014-07-173 ).
1 January 2017 in Applied Bionics and Biomechanics
We described 3D printing technique and automated design software and clinical results after the application of this AFO to a patient with a foot drop. After acquiring a 3D modelling file of a patient’s lower leg with peroneal neuropathy by a 3D scanner, we loaded this file on the automated orthosis software and created the “STL” file. The designed AFO was printed using a fused filament fabrication type 3D printer, and a mechanical stress test was performed. The patient alternated between the 3D-printed and conventional AFOs for 2 months. There was no crack or damage, and the shape and stiffness of the AFO did not change after the durability test. The gait speed increased after wearing the conventional AFO (56.5 cm/sec) and 3D-printed AFO (56.5 cm/sec) compared to that without an AFO (42.2 cm/sec). The patient was more satisfied with the 3D-printed AFO than the conventional AFO in terms of the weight and ease of use. The 3D-printed AFO exhibited similar functionality as the conventional AFO and considerably satisfied the patient in terms of the weight and ease of use. We suggest the possibility of the individualized AFO with 3D printing techniques and automated design software.
1 May 2014 in International Journal of Nanomedicine
Purpose: To evaluate the efficacy of mesenchymal stem cells (MSCs) encapsulated in self-assembled peptide (SAP) hydrogels in a rat knee model for the prevention of osteoarthritis (OA) progression. Materials and methods: Nanostructured KLD-12 SAPs were used as the injectable hydrogels. Thirty-three Sprague Dawley rats were used for the OA model. Ten rats were used for the evaluation of biotin-tagged SAP disappearance. Twenty-three rats were divided into four groups: MSC (n=6), SAP (n=6), SAP-MSC (n=6), and no treatment (n=5). MSCs, SAPs, and SAP-MSCs were injected into the knee joints 3 weeks postsurgery. Histologic examination, immunofluorescent staining, measurement of cytokine levels, and micro-computed tomography analysis were conducted 6 weeks after injections. Behavioral studies were done to establish baseline measurements before treatment, and repeated 3 and 6 weeks after treatment to measure the efficacy of SAP-MSCs. Results: Concentration of biotinylated SAP at week 1 was not significantly different from those at week 3 and week 6 (P=0.565). Bone mineral density was significantly lower in SAP-MSC groups than controls (P=0.002). Significant differences in terminal deoxynucleotidyl transferase deoxyuridine triphosphate nick-end labeling staining between the control group and all other groups were observed. Caspase-8, tissue inhibitor of metalloproteinases 1, and matrix metalloproteinase 9 were diffusely stained in controls, whereas localized or minimal staining was observed in other groups. Modified Mankin scores were significantly lower in the SAP and SAP-MSC groups than in controls (P=0.001 and 0.013). Although not statistically significant, synovial inflammation scores were lower in the SAP (1.3±0.3) and SAP-MSC (1.3±0.2) groups than in controls (2.6±0.2). However, neither the cytokine level nor the behavioral score was significantly different between groups. Conclusion: Injection of SAP-MSC hydrogels showed evidence of chondroprotection, as measured by the histologic grading and decreased expression of biochemical markers of inflammation and apoptosis. It also lowered subchondral bone mineral density, which can be increased by OA. This suggests that the SAP-MSC complex may have clinical potential to inhibit OA progression.
Osteoarthritis (OA) is characterized by a progressive loss of articular cartilage, subchondral bone sclerosis and synovial inflammation and is the most common chronic condition worldwide today. However, most treatments have focused on pain relief and OA symptoms. For these reasons, many ongoing studies are currently trying to develop efficient and successful therapies based on its pathology. Animal models that mimic the histopathology and symptoms of OA have a critical role in OA research and make it possible to investigate both secondary osteoarthritic changes due to a precedent event such as traumatic injury and naturally occurring changes for the development of therapeutics which can be tested in preclinical and clinical OA trials. We induced OA in various animal models including rats, rabbits and guinea pigs by chemical, surgical and naturally occurring methods. In particular, the Dunkin-Hartley guinea pig is very attractive as an OA animal model because OA slowly progresses which is similar to human primary OA. Thus, this animal model mimics the pathophysiological process and environment of human primary OA. Besides the spontaneous OA model, anterior cruciate ligament transection (ACLT) with medial meniscectomy and bilateral ovariectomy (OVX) as well as a chemical technique using sodium monoiodoacetate (MIA) were used to induce OA. We found that ACLT in the rat model induced OA changes in the histology and micro-CT image compared to OVX. The osteoarthritic change significantly increased following ACLT surgery in the rabbit model. Furthermore, we identified that OA pathogenic changes occurred in a time-dependent manner in spontaneous Dunkin-Hartley guinea pigs. The MIA injection model is a rapid and minimally invasive method for inducing OA in animal models, whereas the spontaneous OA model has a slow and gradual progression of OA similar to human primary OA. We observed that histological OA change was extraordinarily increased at 9 ½ months in the spontaneous OA model, and thus, the grade was similar with that of the MIA model. Therefore, this study reports on OA pathology using various animal models as well as the spontaneous results naturally occurring in an OA animal model which had developed cartilage lesions and progressive osteoarthritic changes.