Jiann-Der Lee

Prof. Jiann-Der Lee

Chang Gung University, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jong-Chih ChienJong-Chih Chien
Jong-Chih Chien
MWMing-Tao Wu
Ming-Tao Wu
Jiann-Der LeeJiann-Der Lee
Jiann-Der Lee
Due to advances in semiconductor processing technologies, each slice of a semiconductor is becoming denser and more complex, which can increase the number of surface defects. These defects should be caught early and correctly classified in order help identify the causes of these defects in the process and eventually help to improve the yield. In today’s semiconductor industry, visible surface defects are still being inspected manually, which may result in erroneous classification when the inspectors become tired or lose objectivity. This paper presents a vision-based machine-learning-based method to classify visible surface defects on semiconductor wafers. The proposed method uses deep learning convolutional neural networks to identify and classify four types of surface defects: center, local, random, and scrape. Experiments were performed to determine its accuracy. The experimental results showed that this method alone, without additional refinement, could reach a top accuracy in the range of 98% to 99%. Its performance in wafer-defect classification shows superior performance compared to other machine-learning methods investigated in the experiments.

6 April 2021 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
Jing-Ming GuoJing-Ming Guo
Jing-Ming Guo
HMHerleeyandi Markoni
Herleeyandi Markoni
Jiann-Der LeeJiann-Der Lee
Jiann-Der Lee
Road crack is one of the prominent problems that can frequently occur in highways and main roads. The manual road crack evaluation is laborious, time-consuming, inaccurate, and it has several implementation issues. Conversely, the computer vision-based solution is very challenging due to the complex ambient conditions, including illumination, shadow, dust, and crack shape. Most of the cracks exist as irregular edge patterns and are the most important features for detection purpose. Recent advances in deep learning adopt a convolutional neural network as the base model to detect and localize crack with a single RGB image. Yet, this approach has an inaccurate boundary for crack localization, resulting in thicker and blurry edges. To overcome this problem, the study proposes a novel and robust road crack detection based on deep learning which also considers the original edge of the image as the additional feature. The main contribution of this work is adapting the original image gradient with the coarse crack detection result and refining it to produce more precise crack boundaries. Extensive experimental results have shown that the proposed method outperforms the former state-of-the-art methods in terms of the detection accuracy.

1 January 2013 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
SYShih-Ting Yang
Shih-Ting Yang
Jiann-Der LeeJiann-Der Lee
Jiann-Der Lee
TCTzyh-Chyang Chang
Tzyh-Chyang Chang
CHChung-Hsien Huang
Chung-Hsien Huang
JWJiun-Jie Wang
Jiun-Jie Wang
KLKuan-yi Li
Kuan-yi Li
In this study, an MRI-based classification framework was proposed to distinguish the patients with AD and MCI from normal participants by using multiple features and different classifiers. First, we extracted features (volume and shape) from MRI data by using a series of image processing steps. Subsequently, we applied principal component analysis (PCA) to convert a set of features of possibly correlated variables into a smaller set of values of linearly uncorrelated variables, decreasing the dimensions of feature space. Finally, we developed a novel data mining framework in combination with support vector machine (SVM) and particle swarm optimization (PSO) for the AD/MCI classification. In order to compare the hybrid method with traditional classifier, two kinds of classifiers, that is, SVM and a self-organizing map (SOM), were trained for patient classification. With the proposed framework, the classification accuracy is improved up to 82.35% and 77.78% in patients with AD and MCI. The result achieved up to 94.12% and 88.89% in AD and MCI by combining the volumetric features and shape features and using PCA. The present results suggest that novel multivariate methods of pattern matching reach a clinically relevant accuracy for the a priori prediction of the progression from MCI to AD.

1 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jong-Chih ChienJong-Chih Chien
Jong-Chih Chien
Jiann-Der LeeJiann-Der Lee
Jiann-Der Lee
CHChing-Shu Hu
Ching-Shu Hu
CWChieh-Tsai Wu
Chieh-Tsai Wu
In modern medicine, medical imaging technologies such as computed tomography (CT), X-ray, ultrasound, magnetic resonance imaging (MRI), nuclear medicine, etc., have been proven to provide useful diagnostic information by displaying areas of a lesion or tumor not visible to the human eye, and may also help provide additional recessive information by using modern data analysis methods. These methods, including Artificial Intelligence (AI) technologies, are based on deep learning architectures, and have shown remarkable results in recent studies. However, the lack of explanatory ability of connection-based, instead of algorithm-based, deep learning technologies is one of the main reasons for the delay in the acceptance of these technologies in the mainstream medical field. One of the recent methods that may offer the explanatory ability for the CNN classes of deep learning neural networks is the gradient-weighted class activation mapping (Grad-CAM) method, which produces heat-maps that may offer explanations of the classification results. There are already many studies in the literature that compare the objective metrics of Grad-CAM-generated heat-maps against other methods. However, the subjective evaluation of AI-based classification/prediction results using medical images by qualified personnel could potentially contribute more to the acceptance of AI than objective metrics. The purpose of this paper is to investigate whether and how the Grad-CAM heat-maps can help physicians and radiologists in making diagnoses by presenting the results from AI-based classifications as well as their associated Grad-CAM-generated heat-maps to a qualified radiologist. The results of this study show that the radiologist considers Grad-CAM-generated heat-maps to be generally helpful toward diagnosis.

8 May 2012 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
Jing-Ming GuoJing-Ming Guo
Jing-Ming Guo
CSChang-Cheng Su
Chang-Cheng Su
YLYun-Fu Liu
Yun-Fu Liu
HLHua Lee
Hua Lee
Jiann-Der LeeJiann-Der Lee
Jiann-Der Lee
In this paper, a halftoning-based watermarking method is presented. This method enables high pixel-depth watermark embedding, while maintaining high image quality. This technique is capable of embedding watermarks with pixel depths up to 3 bits without causing prominent degradation to the image quality. To achieve high image quality, the parallel oriented high-efficient direct binary search (DBS) halftoning is selected to be integrated with the proposed orientation modulation (OM) method. The OM method utilizes different halftone texture orientations to carry different watermark data. In the decoder, the least-mean-square-trained filters are applied for feature extraction from watermarked images in the frequency domain, and the naïve Bayes classifier is used to analyze the extracted features and ultimately to decode the watermark data. Experimental results show that the DBS-based OM encoding method maintains a high degree of image quality and realizes the processing efficiency and robustness to be adapted in printing applications.

15 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Jong-Chih ChienJong-Chih Chien
Jong-Chih Chien
YTYao-Ren Tsai
Yao-Ren Tsai
CWChieh-Tsai Wu
Chieh-Tsai Wu
Jiann-Der LeeJiann-Der Lee
Jiann-Der Lee
By the standard of today’s image-guided surgery (IGS) technology, in order to check and verify the progress of the surgery, the surgeons still require divert their attention from the patients occasionally to check against the display. In this paper, a mixed-reality system for medical use is proposed that combines an Intel RealSense sensor with Microsoft’s Hololens head-mounted display system, for superimposing medical data onto the physical surface of a patient, so the surgeons do not need to divert their attention from their patients. The main idea of our proposed system is to display the 3D medical images of the patients on the actual patients themselves by placing the medical images and the patients in the same coordinate space. However, the virtual medical data may contain noises and outliers, so the transformation mapping function must be able to handle these problems. The transform function in our system is performed by the use of our proposed Denoised-Resampled-Weighted-and-Perturbed-Iterative Closest Points (DRWP-ICP) algorithm, which performs denoising and removal of outliers before aligning the pre-operative medical image data points to the patient’s physical surface position before displaying the result using the Microsoft HoloLens display system. The experimental results shows that our proposed mixed-reality system using DRWP-ICP is capable of performing accurate and robust mapping despite the presence of noise and outliers.