Ding-xi Liu

Prof. Ding-xi Liu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
WWWenjun Wu
Wenjun Wu
FWFeihong Wu
Feihong Wu
DLDing-xi Liu
Ding-xi Liu
CZChuansheng Zheng
Chuansheng Zheng
XKXiangquan Kong
Xiangquan Kong
LWLixia Wang
Lixia Wang

6 May 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HZHeng Zhai
Heng Zhai
YLYinzhang Lv
Yinzhang Lv
XKXiangquan Kong
Xiangquan Kong
XLXi Liu
Xi Liu
DLDing-xi Liu
Ding-xi Liu
Imaging appearances of peripheral nerve sheath tumors by MRI are difficult distinguish from soft-tissue tumors. The objective of this study was to evaluate the feasibility and imaging appearance of high-resolution 3-T magnetic resonance neurography (MRN) of the diagnosis of peripheral nerve sheath tumors (PNSTs) using sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences. We retrospectively evaluated the MRI and 3D Short tau inversion recovery sampling perfection with application-optimized contrasts using varying flip-angle evolutions (3D-STIR SPACE) sequences of 30 patients with PNSTs diagnosed by surgery and pathology. The contrast-enhanced 3D-STIR SPACE images were retrospectively analyzed and evaluated for the visualization of PNSTs. The tumors were evaluated by their number, location, morphology, size, signal intensity and enhancement characteristics. The imaging findings and characteristic signs of conventional MRI scanning and contrast-enhanced 3D-STIR SPACE sequences were compared. In these cases, conventional MRI images display the location, number, shape, size and signal characteristics of the lesions. These tumors were mostly solitary and had a well-defined boundary. Compared to conventional MRI images, imaging appearances including neurogenic origin, length of the peripheral nerves and relation to the nerve of PNSTs on 3D-STIR SPACE images were more accuracy (P < 0.05). Compared to 3D-STIR SPACE images, contrast-enhanced images can more clearly display background suppression of the peripheral nerves. The “split fat” sign and “target” sign were seen in some patients. 3D STIR SPACE sequences demonstrate its significant capacity to diagnostic evaluate and location of PNSTs. This article comprehensively reviews radiologic findings and illustrates the MRN features of PNSTs. 3D-STIR SPACE sequences be used for preoperative evaluation of PNSTs.

5 January 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
ZQZiji Qin
Ziji Qin
WWWenjun Wu
Wenjun Wu
DLDing-xi Liu
Ding-xi Liu
CZChuansheng Zheng
Chuansheng Zheng
JKJiamin Kang
Jiamin Kang
LWLixia Wang
Lixia Wang



1 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
QFQing Fu
Qing Fu
DLDing-xi Liu
Ding-xi Liu
HMHui Ma
Hui Ma
KZKun Zhou
Kun Zhou
TYTing Yin
Ting Yin
ZLZi-qiao Lei
Zi-qiao Lei
Purpose: To investigate feasibility and diagnostic performance of turbo gradient and spin-echo BLADE (proprietary name for Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction [PROPELLER] in Siemens MR systems)-diffusion weighted imaging (TGSE-BLADE-DWI) for depicting extraocular muscle (EOM) involvement and activity in thyroid-associated ophthalmopathy (TAO), and to compare TGSE-BLADE-DWI with readout-segmented echo-planar imaging (RESOLVE). Materials and methods: Thirty-five patients with identified TAO underwent the two DWI scans. Two radiologists visually scored the image quality of the two DWIs with respect to the susceptibility artifacts and geometric distortions on a three-point scale. The maximum size (Sizemax) of EOMs and corresponding ADCs (cADCs) of each patient were compared between the active and inactive phases. The clinical activity score (CAS) was used as a reference to assess the diagnostic performance of EOM ADCs for grading TAO activity. ROC analysis, Pearson correlation, and Wilcoxon signed-rank test were used for statistical analyses. Results: For scores of EOMs, the image quality of TGSE-BLADE-DWI was significantly higher than that of RESOLVE. There were no statistically significant differences between the AUCs of the two DWIs, Sizemax, or cADCs between the active and inactive phases. TGSE-BLADE-DWI ADCs were significantly higher than the RESOLVE ADCs in the right superior rectus, right lateral rectus, left superior rectus, and left inferior rectus. There were no statistically significant correlations between the cADC or Sizemax, and CAS. The highest AUC was 0.697 for RESOLVE and 0.657 for TGSE-BLADE-DWI. The best performing ADC threshold was 1.85 × 10−3 mm2/s with 85.7% sensitivity, 58.8% specificity and 66.67% accuracy for RESOLVE and 1.99 × 10−3 mm2/s with 79.0% sensitivity, and 55.6% specificity and 65.27% accuracy for TGSE-BLADE-DWI. Conclusion: Compared to RESOLVE, TGSE-BLADE-DWI provided improved image quality with fewer susceptibility artifacts and geometric distortions for EOM visualization and showed an equivalent performance in detecting active TAO.