David Lurie

Prof. David Lurie

orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 1988 in Journal of Magnetic Resonance (1969)
Verified
Journal Article
Closed access
DLDavid Lurie
David Lurie
DBDavid M Bussell
David M Bussell
LBLawrence H Bell
Lawrence H Bell
JMJohn R Mallard
John R Mallard

15 June 2005 in Advanced Drug Delivery Reviews
Verified
Journal Article
Closed access
DLDavid Lurie
David Lurie
Karsten MäderKarsten Mäder
Karsten Mäder

18 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LBLionel Broche
Lionel Broche
PRP. James Ross
P. James Ross
GDGareth R. Davies
Gareth R. Davies
MMMary-Joan MacLeod
Mary-Joan MacLeod
DLDavid Lurie
David Lurie
Fast Field-Cycling (FFC) is a well-established Nuclear Magnetic Resonance (NMR) technique that exploits varying magnetic fields to quantify molecular motion over a wide range of time scales, providing rich structural information from nanometres to micrometres, non-invasively. Previous work demonstrated great potential for FFC-NMR biomarkers in medical applications; our research group has now ported this technology to medical imaging by designing a whole-body FFC Magnetic Resonance Imaging (FFC-MRI) scanner capable of performing accurate measurements non-invasively over the entire body, using signals from water and fat protons. This is a unique tool to explore new biomarkers related to disease-induced tissue remodelling. Our approach required making radical changes in the design, construction and control of MRI hardware so that the magnetic field is switched within 12.5 ms to reach any field strength from 50 μT to 0.2 T, providing clinically useful images within minutes. Pilot studies demonstrated endogenous field-dependant contrast in biological tissues in good agreement with reference data from other imaging modalities, confirming that our system can perform multiscale structural imaging of biological tissues, from nanometres to micrometres. It is now possible to confirmex vivoresults obtained from previous clinical studies, offering applications in diagnosis, staging and monitoring treatment for cancer, stroke, osteoarthritis and oedema.

1 July 1998 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
DLDavid Lurie
David Lurie
MFMargaret A Foster
Margaret A Foster
DYDavid Yeung
David Yeung
JHJames M S Hutchison
James M S Hutchison
The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magnet with an internal diameter of 52 cm. The magnetic field can be switched from zero to 59 mT or vice versa in 40 ms. It is used with a double-resonance coil assembly (NMR/EPR) comprising a solenoidal NMR transmit/receive coil and a coaxial, external birdcage resonator for EPR irradiation. Experiments to image the distribution of an exogenous nitroxide free radical in anaesthetized rabbits are described.

1 February 2005 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
DLDavid Lurie
David Lurie
GDGareth R. Davies
Gareth R. Davies
MFMargaret A. Foster
Margaret A. Foster
JHJames M.S. Hutchison
James M.S. Hutchison

1 March 2010 in Comptes Rendus. Physique
Verified
Journal Article
Closed access
DLDavid Lurie
David Lurie
SASilvio Aime
Silvio Aime
SBSimona Baroni
Simona Baroni
NBNuala A. Booth
Nuala A. Booth
LBLionel Broche
Lionel Broche
KPKerrin J. Pine
Kerrin J. Pine