Katarzyna Grygoyć

Mrs. Katarzyna Grygoyć

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

2 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
JWJoanna Willner
Joanna Willner
AFAgnieszka Fornalczyk
Agnieszka Fornalczyk
Magdalena Jabłońska-CzaplaMagdalena Jabłońska-Czapla
Magdalena Jabłońska-Czapla
KGKatarzyna Grygoyć
Katarzyna Grygoyć
MRMarzena Rachwał
Marzena Rachwał
The article draws attention to the problem of the presence of metals: germanium (Ge), tellurium (Te), thallium (Tl), and others (Cd, Ba, Co, Mn, Cr, Cu, Ni, Pb, Sr, and Zn) in selected waste of electrical and electronic equipment (WEEE). As a result of the growing demand for new technologies, the global consumption of TECs has also been increasing. Thus, the amount of metals in circulation, of which the impacts on the environment have not yet been fully understood, is constantly increasing. Due to the low content of these metals in WEEE, they are usually ignored during e-waste analyses. The main aim of this study was to determine the distribution of Ge, Te, and Tl (and other elements) in ground sieve fractions (1.0, 0.5, 0.2, and 0.1 mm) of selected electronic components (solar lamps, solar cell, LED TV screens, LCD screens, photoresistors, photodiodes, phototransistors) and to determine the possible tendency of the concentrations of these metals in fractions. This problem is particularly important because WEEE recycling processes (crushing, grinding, and even collection and transport operations) can lead to dispersion and migration of TCE pollutants into the environment. The quantitative composition of e-waste was identified and confirmed by ICP-MS, ICP-OES and SEM-EDS, and XRD analyses. It was found that Ge, Te, and Tl are concentrated in the finest fractions of ground e-waste, together with Cd and Cr, which may favor the migration of these pollutants in the form of dust during storage and processing of e-waste.

30 April 2021 in Molecules
Verified
Journal Article
Open access
PDF file
KGKatarzyna Grygoyć
Katarzyna Grygoyć
Magdalena Jabłońska-CzaplaMagdalena Jabłońska-Czapla
Magdalena Jabłońska-Czapla
The optimization and validation of a methodology for determining and extracting inorganic ionic Te(VI) and Te(IV) forms in easily-leached fractions of soil by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry (IC-ICP-MS) were studied. In this paper, the total concentration of Te, pH, and red-ox potential were determined. Ions were successfully separated in 4 min on a Hamilton PRPX100 column with 0.002 mg/kg and 0.004 mg/kg limits of detection for Te(VI) and Te(IV), respectively. Soil samples were collected from areas subjected to the influence of an electrowaste processing and sorting plant. Sequential chemical extraction of soils showed that tellurium was bound mainly with sulphides, organic matter, and silicates. Optimization of soil extraction allowed 20% average extraction efficiency to be obtained, using 100 mM citric acid as the extractant. In the tested soil samples, both tellurium species were present. In most cases, the soils contained a reduced Te form, or the concentrations of both species were similar.

10 May 2016 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
RMRajmund Michalski
Rajmund Michalski
Magdalena Jabłońska-CzaplaMagdalena Jabłońska-Czapla
Magdalena Jabłońska-Czapla
SSSebastian Szopa
Sebastian Szopa
AŁAleksandra Łyko
Aleksandra Łyko
KGKatarzyna Grygoyć
Katarzyna Grygoyć
Migration of metals/metalloids and their inorganic forms from bottom sediments into waters and from waters into bottom sediments is a complex process. Understanding this mechanism is essential for recognising transformations that occur in water reservoir ecosystems. The following research was conducted in 2012–2014. The aim was to define the time and spatial correlations in the changes of total and ionic antimony, arsenic and chromium concentrations in waters and bottom sediments of three water reservoirs located in Upper Silesia (Poland), i.e. Pławniowice, Rybnik and Goczałkowice. The ionic form contents were determined with high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS). The research was carried out to verify whether the bottom sediments deposited in the discussed reservoirs could have posed an environmental threat due to the possible release of toxic ionic forms (i.e. As(III), Sb(III) and Cr(VI)) into the pelagic zone. The comparison of the research results obtained for three reservoirs (being under different anthropopressure influence) enabled the researchers to describe the bioavailability of specific elements and their species. It also helped to discern the existing environmental threats for such water reservoirs and their users.

APAdam Prokopowicz
Adam Prokopowicz
Andrzej SobczakAndrzej Sobczak
Andrzej Sobczak
JSJerzy Szdzuj
Jerzy Szdzuj
KGKatarzyna Grygoyć
Katarzyna Grygoyć
Leon KośmiderLeon Kośmider
Leon Kośmider
Background: E-cigarettes (ECs) seem to be a less harmful alternative for conventional cigarettes, however, very little is still known about the exposure to some elements, which are the components of this device and may contaminate the nicotine liquid. The aim of this study is to assess whether e-cigarette users are more exposed to 12 elements detected in aerosol than non-smokers and conventional cigarette smokers, using their concentrations in urine as exposure biomarkers. Methods: A cross-sectional, group-based survey was carried out using 90 volunteers classified into groups of non-smokers, EC-only users, dual EC users-cigarette smokers and cigarette-only smokers. Using inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (ETAAS), Cr, Ni, Co, Ag, In, Mn, Ba, Sr, V, Sb, Cd and Pb levels were measured in spot urine samples. Among the selected groups, a comparison was made using the analysis of covariance and correlations with EC usage pattern were assessed by multiple linear regression. Results: Element concentrations in urine of EC-users were not significantly different from the levels found in non-smokers and smokers. Only in the case of Ba, Ni and Sb was a significant correlation found in relation to some e-cigarette usage patterns. Conclusion: Transfer of the investigated elements to the EC aerosol was not found to be a substantial source of exposure in EC users who quitted smoking.

31 October 2020 in Journal of Environmental Health Science and Engineering
Verified
Journal Article
Open access
PDF file
RMRajmund Michalski
Rajmund Michalski
PPPaulina Pecyna-Utylska
Paulina Pecyna-Utylska
JKJoanna Kernert
Joanna Kernert
KGKatarzyna Grygoyć
Katarzyna Grygoyć
JKJustyna Klyta
Justyna Klyta
The research focused on assessing the risk to human health resulting from the content of selected Cr, Co, Mn, Cu, Ni, Pb, As, Zn and Sr metals in tap water supplied by Upper Silesia Water Plant to the inhabitants of the Upper Silesia region (Poland). It is the main supplier of drinking water to several million inhabitants of this agglomeration. Samples were taken and analyzed quarterly in 2019. The sampling points were chosen to help identify the source when an elevated level of a particular contaminant is observed. ICP-MS and ICP-OES have been used to measure the concentrations of those elements. The chronic daily intake (CDI), hazard quotient (HQ) and hazard index (HI) results for non-carcinogenic risk assessment of metals in tap water has been assessed. CDI values of non-carcinogenic metals were higher in children than in adults; the CDI values for adults and children were found in the order of: Zn > Sr > Cu > Mn > Ni > Pb > Cr > Co > As. All the studied metals had HQ values below 1, the risks caused by the non-carcinogenic metals decreased in the following order: Zn > Cu > Co > As > Sr > Pb > Cr > Ni > Mn. HI values were also less than 1, that meaning that the analyzed tap water is safe for human consumption. The concentration of As, Cr, Cu, Mn and Ni in analyzed tap water is in accordance with Polish and international requirements.